An intensity-modulated proton therapy (IMPT) patient-specific quality assurance (PSQA) program based on measurement alone can be very time consuming due to the highly modulated dose distributions of IMPT fields. Incorporating independent dose calculation and treatment log file analysis could reduce the time required for measurements. In this article, we summarize our effort to develop an efficient and effective PSQA program that consists of three components: measurements, independent dose calculation, and analysis of patient-specific treatment delivery log files. Measurements included two-dimensional (2D) measurements using an ionization chamber array detector for each field delivered at the planned gantry angles with the electronic medical record (EMR) system in the QA mode and the accelerator control system (ACS) in the treatment mode, and additional measurements at depths for each field with the ACS in physics mode and without the EMR system. Dose distributions for each field in a water phantom were calculated independently using a recently developed in-house pencil beam algorithm and compared with those obtained using the treatment planning system (TPS). The treatment log file for each field was analyzed in terms of deviations in delivered spot positions from their planned positions using various statistical methods. Using this improved PSQA program, we were able to verify the integrity of the data transfer from the TPS to the EMR to the ACS, the dose calculation of the TPS, and the treatment delivery, including the dose delivered and spot positions. On the basis of this experience, we estimate that the in-room measurement time required for each complex IMPT case (e.g., a patient receiving bilateral IMPT for head and neck cancer) is less than 1 h using the improved PSQA program. Our experience demonstrates that it is possible to develop an efficient and effective PSQA program for IMPT with the equipment and resources available in the clinic.
1 October 2011 in International Journal of Radiation Oncology, Biology, Physics
Intensity modulated proton therapy (IMPT) plans are normally generated utilizing multiple field optimization (MFO) techniques. Similar to photon based IMRT, MFO allows for the utilization of a simultaneous integrated boost in which multiple target volumes are treated to discrete doses simultaneously, potentially improving plan quality and streamlining quality assurance and treatment delivery. However, MFO may render plans more sensitive to the physical uncertainties inherent to particle therapy. Here we present clinical examples of a single-field integrated boost (SFIB) technique for spot scanning proton therapy based on single field optimization (SFO) treatment-planning techniques. We designed plans of each type for illustrative patients with central nervous system (brain and spine), prostate and head and neck malignancies. SFIB and IMPT plans were constructed to deliver multiple prescription dose levels to multiple targets using SFO or MFO, respectively. Dose and fractionation schemes were based on the current clinical practice using X-ray IMRT in our clinic. For inverse planning, dose constraints were employed to achieve the desired target coverage and normal tissue sparing. Conformality and inhomogeneity indices were calculated to quantify plan quality. We also compared the worst-case robustness of the SFIB, sequential boost SFUD, and IMPT plans. The SFIB technique produced more conformal dose distributions than plans generated by sequential boost using a SFUD technique (conformality index for prescription isodose levels; 0.585 ± 0.30 vs. 0.435 ± 0.24, SFIB vs. SFUD respectively, Wilcoxon matched-pair signed rank test, p < 0.01). There was no difference in the conformality index between SFIB and IMPT plans (0.638 ± 0.27 vs. 0.633 ± 0.26, SFIB vs. IMPT, respectively). Heterogeneity between techniques was not significantly different. With respect to clinical metrics, SFIB plans proved more robust than the corresponding IMPT plans. SFIB technique for scanning beam proton therapy (SSPT) is now routinely employed in our clinic. The SFIB technique is a natural application of SFO and offers several advantages over SFUD, including more conformal plans, seamless treatment delivery and more efficient planning and QA. SFIB may be more robust than IMPT and has been the treatment planning technique of choice for some patients.
To assess the worst-case robust optimization IMPT plans with setup and range uncertainties and to test the hypothesis that the worst-case robust optimization strategies could cover most possible setup and range uncertainties in the real scenarios. We analyzed the nominal and worst-case robust optimization IMPT plans of seven patients with head and neck cancer patients. To take uncertainties into account for the dose calculation, we performed a comprehensive simulation in which the dose was recalculated 625 times per given plan using Gaussian systematic setup and proton range uncertainties. Subsequently, based on the simulation results, we calculated the target coverage in all perturbation scenarios, as well as the ratios of target coverage located within the threshold of eight worst-case scenarios. We set the criteria for the optimized plan to be the ratios of 1) the dose delivered to 95% (D95%) of clinical target volumes 1 and 2 (CTV1 and CTV2) above 95% of the prescribed dose, and 2) the D95% of clinical target volume 3 (CTV3) above 90% of the prescribed dose in worst-case situations. The probability that the perturbed-dose indices of the CTVs in each scenario were within the worst-case scenario limits ranged from 89.51 to 91.22% for both the nominal and worst-case robust optimization IMPT plans. A quartile analysis showed that the selective robust optimization IMPT plans all had higher D95% values for CTV1, CTV2, and CTV3 than did the nominal IMPT plans. The worst-case strategy for robust optimization is adequately models and covers most of the setup and range uncertainties for the IMPT treatment of head and neck patients in our center.