Jinhai Huang

Dr. Jinhai Huang


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
DWDaizong Wen
Daizong Wen
CMColm McAlinden
Colm McAlinden
DFDaniel Ian Flitcroft
Daniel Ian Flitcroft
RTRuixue Tu
Ruixue Tu
QWQinmei Wang
Qinmei Wang
JHJinhai Huang
Jinhai Huang

21 January 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JYJi-Guo Yu
Ji-Guo Yu
YFYi-Fan Feng
Yi-Fan Feng
YXYi Xiang
Yi Xiang
JHJinhai Huang
Jinhai Huang
GSGiacomo Savini
Giacomo Savini
XFXun-An Fu
Xun-An Fu
Parkinson disease (PD) is a neurodegenerative process that leads to a selective loss of dopaminergic neurons, mainly in the basal ganglia of the brain. Numerous studies have analyzed the ability of optical coherence tomography (OCT) to detect retinal nerve fiber layer (RNFL) thickness abnormalities and changes in PD, but the results have not always been consistent. Therefore, we carried out a meta-analysis to evaluate the RNFL thickness measured with OCT in PD. Case-control studies were selected through an electronic search of the Cochrane Controlled Trials Register, PUBMED and EMBASE. For the continuous outcomes, we calculated the weighted mean difference (WMD) and 95% confidence interval (CI). The statistical analysis was performed by RevMan 5.0 software. Thirteen case-control studies were included in the present meta-analysis, containing a total of 644 eyes in PD patients and 604 eyes in healthy controls. The results of our study showed that there was a significant reduction in average RNFL thickness in patients with PD compared to healthy controls (WMD = −5.76, 95% CI: −8.99 to −2.53, P = 0.0005). Additionally, differences of RNFL thickness in superior quadrant (WMD = −4.44, 95% CI: −6.93 to −1.94, P = 0.0005), inferior quadrant (WMD = −7.56, 95% CI: −11.33 to −3.78, P<0.0001), nasal quadrant (WMD = −3.12, 95% CI: −5.63 to −0.61, P = 0.01) and temporal quadrant (WMD = −4.63, 95% CI: −7.20 to −2.06, P = 0.0004) were all significant between the two groups. In view of these results and the noninvasive nature of OCT technology, we surmise that OCT could be a useful tool for evaluating the progression of the Parkinson disease. ClinicalTrials.gov NCT01928212

25 September 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
QWQinmei Wang
Qinmei Wang
GSGiacomo Savini
Giacomo Savini
KHKenneth J. Hoffer
Kenneth J. Hoffer
ZXZhen Xu
Zhen Xu
YFYifan Feng
Yifan Feng
JHJinhai Huang
Jinhai Huang
To comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices. Thirty-five eyes from 35 healthy subjects were included in the prospective study. In the first session, a single examiner performed on each subject randomly measurements with the RC-5000 (Tomey Corp., Japan), KR-8000 (Topcon, Japan), IOLMaster (Carl Zeiss Meditec, Germany), E300 (Medmont International, Australia), Allegro Topolyzer (Wavelight AG, Germany), Vista (EyeSys, TX), Pentacam (Oculus, Germany) and Sirius (CSO, Italy). Measurements were repeated in the second session (1 to 2 weeks later). Repeatability and reproducibility of corneal power measurements were assessed based on the intrasession and intersession within-subject standard deviation (Sw), repeatability (2.77Sw), coefficient of variation (COV), and intraclass correlation coefficient (ICC). Agreement was evaluated by 95% limits of agreement (LoA). All devices demonstrated high repeatability and reproducibility of the keratometric values (2.77Sw<0.36D, COV0.98). Repeated-measures analysis of variance with Bonferroni post test showed statistically significant differences (P<0.01) among mean keratometric values of most instruments; the largest differences were observed between the EyeSys Vista and Medmont E300. Good agreement (i.e., 95%LoA within ±0.5D) was found between most instruments for flat, steep and mean keratometry, except for EyeSys and Medmont. Repeatability and reproducibility of vectors J0 and J45 was good, as the ICCs were higher than 0.9, except J45 of Medmont and Pentacam. For the 95% LoAs of J0 and J45, they were all ≤ ±0.31 among any two paired devices. The 8 devices showed excellent repeatability and reproducibility. The results obtained using the RC-5000, KR-8000, IOLMaster, Allegro Topolyzer, Pentacam and Sirius were comparable, suggesting that they could be used interchangeably in most clinical settings. Caution is warranted with the measurements of the EyeSys Vista and Medmont E300, which should not be used interchangeably with other devices due to lower agreement. ClinicalTrials.gov NCT01587287

1 October 2013 in Ophthalmology
Verified
Journal Article
Closed access
JHJinhai Huang
Jinhai Huang
XDXixia Ding
Xixia Ding
GSGiacomo Savini
Giacomo Savini
CPChao Pan
Chao Pan
YFYifan Feng
Yifan Feng
QWQinmei Wang
Qinmei Wang

27 October 2023 in ACS Nano
Verified
Journal Article
Closed access
XLXinyu Liu
Xinyu Liu
ZCZhongxing Chen
Zhongxing Chen
JBJieyi Bai
Jieyi Bai
XLXin Li
Xin Li
XCXin Chen
Xin Chen
JHJinhai Huang
Jinhai Huang

27 July 2012 in Acta Ophthalmologica
Verified
Journal Article
Open access
PDF file
SCShihao Chen
Shihao Chen
JHJinhai Huang
Jinhai Huang
DWDaizong Wen
Daizong Wen
WCWuhe Chen
Wuhe Chen
DHDavid Huang
David Huang
QWQinmei Wang
Qinmei Wang
: Purpose:  To compare the repeatability and reproducibility of central corneal thickness (CCT) measurements by high‐resolution (HR) rotating Scheimpflug imaging and Fourier‐domain optical coherence tomography (FD‐OCT). CCT measurements were compared to those determined by ultrasound pachymetry (UP).Methods:  In 35 healthy eyes, intra‐observer repeatability for HR Scheimpflug (Pentacam) and FD‐OCT (RTVue) systems was determined in consecutive images taken by an observer in the shortest time possible. Imaging was repeated again by a second observer to evaluate inter‐observer reproducibility. The CCT measurements were compared among Scheimpflug, FD‐OCT and UP images.Results:  Mean coefficients of repeatability were 0.48% for Scheimpflug and 0.26% for FD‐OCT. For Scheimpflug, the coefficient of inter‐operator reproducibility was 0.87%. For FD‐OCT, the coefficient of inter‐operator reproducibility was 0.45%. The CCT measurements by Scheimpflug, OCT and UP images were (mean ± standard deviation) 521.7 ± 27.6 μm, 510.8 ± 28.6 μm and 516.5 ± 27.6 μm, respectively. The differences between instruments were statistically significant. The 95% limits of agreement in CCT were −0.7 to 22.5 μm for Pentacam‐OCT, −13.4 to 24.0 μm for Pentacam‐UP and −26.7 to 15.4 μm for OCT‐UP. There was a high degree of correlation between CCT measured by all 3 methods.Conclusion:  Noncontact measurements of CCT with HR Scheimpflug and FD‐OCT systems yielded excellent repeatability and reproducibility and can be used interchangeably. Although both devices were comparable with UP; in clinical practice, the measurements acquired by optical modalities are not directly interchangeable with UP measurements.