Ali Djerioui

Prof. Dr. Ali Djerioui

Electrical Engineering Laboratory, Department of Electrical Engineering, University of M’sila, M’sila 28000, Algeria
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in ISA Transactions
Verified
Journal Article
Closed access
Samir ZEGHLACHESamir ZEGHLACHE
Samir ZEGHLACHE
HMHemza Mekki
Hemza Mekki
ABAbderrahmen Bouguerra
Abderrahmen Bouguerra
Ali DjeriouiAli Djerioui
Ali Djerioui

1 December 2019 in ISA Transactions
Verified
Journal Article
Closed access
Samir ZEGHLACHESamir ZEGHLACHE
Samir ZEGHLACHE
Ali DjeriouiAli Djerioui
Ali Djerioui
LBLoutfi Benyettou
Loutfi Benyettou
TBTarak Benslimane
Tarak Benslimane
HMHemza Mekki
Hemza Mekki
ABAbderrahmen Bouguerra
Abderrahmen Bouguerra

20 April 2020 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
Seydali FerahtiaSeydali Ferahtia
Seydali Ferahtia
Ali DjeriouiAli Djerioui
Ali Djerioui
Samir ZEGHLACHESamir ZEGHLACHE
Samir ZEGHLACHE
Azeddine HouariAzeddine Houari
Azeddine Houari
In this study, we present an ameliorated power management method for dc microgrid. The importance of exploiting renewable energy has long been a controversial topic, and due to the advantages of DC over the AC type, a typical DC islanded micro-grid has been proposed in this paper. This typical microgrid is composed of two sources: fuel cell (FC), solar cell (PV) and one storage element [supercapacitor (SC)]. Here, we aimed to provide a management strategy that guarantees optimized bus voltage with arranged power-sharing between the sources. This proposed management aims to provide high-quality energy to the load under different loading conditions with variable solar irradiance, taking into account the FC state. Due to the slow dynamics of the FC, the SC was equipped to supply the transient period. A management algorithm is implemented to hold the DC bus voltage stable against the load variations. The management controller is based on differential flatness approach to generate the references. The DC bus is regulated by the SC energy; to reduce the fluctuations in the DC bus voltage, The PI controller is implemented. This proposed strategy reduces the voltage ripple in the DC bus. Moreover, it provides permanent supplying to the load with smooth behaviour over the sudden changes in the demand as depicted in the simulation results. Our study revealed that this proposed manager can be used for this kind of grids easily.

6 December 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Ali DjeriouiAli Djerioui
Ali Djerioui
Azeddine HouariAzeddine Houari
Azeddine Houari
ASAbdelhakim Saim
Abdelhakim Saim
MAMourad Ait-Ahmed
Mourad Ait-Ahmed
SPSerge Pierfederici
Serge Pierfederici
MGMalek Ghanes
Malek Ghanes
Standalone power-supply systems become a key solution to effectively address the load demand in remote locations, wherein the voltage asymmetry raises as a particular concern in view of a large number of single-phase household and communities loads. Over these loading conditions, the use of the four-leg voltage source inverters (FL-VSIs) appears as a suitable topology to provide clean power with symmetrical voltage waveforms. The reported work employs the differential flatness theory associated with grey wolf optimization in order to guarantee proper operations of the FL-VSIs in different loading conditions. In fact, the differential flatness theory is applied to check the flatness of the FL-VSIs, which allows implementing a reduced control model. Then, a grey wolf algorithm, which acts as a tracking controller [grey wolf controller (GWC)], is developed. The GWC generates an optimal control signal used by the differentially flat model so as to ensure adequate control performance, even under severe load disturbances and model inaccuracies. A comprehensive experimental test is carried out to validate the effectiveness of the proposed flatness-based grey wolf controller.

17 August 2017 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Azeddine HouariAzeddine Houari
Azeddine Houari
ABAhmed Bouabdallah
Ahmed Bouabdallah
Ali DjeriouiAli Djerioui
Ali Djerioui
Mohamed MachmoumMohamed Machmoum
Mohamed Machmoum
Francois AUGERFrancois AUGER
Francois AUGER
Mohamed Fouad BENKHORISMohamed Fouad BENKHORIS
Mohamed Fouad BENKHORIS
This paper proposes a simple and effective method to reduce speed ripples of Permanent Magnet Synchronous Machines (PMSMs) at low speed working conditions. The treated issue is related to the periodic torque ripples which induce speed oscillations that deteriorate the drive performance. The main idea of the proposed method is to modify a conventional PMSM controller by superposing an appropriate compensation signal to the quadratic-current reference. The proposed approach allows to reduce speed ripples at low speed through a simple compensation signal and does not require a hard calculation cost. A theoretical analysis is presented, and both simulation and experimental results are presented to validate the proposed compensation method.

1 March 2018 in ISA Transactions
Verified
Journal Article
Closed access
Ali DjeriouiAli Djerioui
Ali Djerioui
Azeddine HouariAzeddine Houari
Azeddine Houari
MAMourad Ait-Ahmed
Mourad Ait-Ahmed
MBMohamed-Fouad Benkhoris
Mohamed-Fouad Benkhoris
ACAissa Chouder
Aissa Chouder
MMMohamed Machmoum
Mohamed Machmoum