Marika Mannerstrom

Dr. Marika Mannerstrom


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2022 in Journal of Fungi
Verified
Journal Article
Open access
PDF file
KVKirsi Vaali
Kirsi Vaali
MTMarja Tuomela
Marja Tuomela
MMMarika Mannerstrom
Marika Mannerstrom
THTuula Heinonen
Tuula Heinonen
Tamara TuuminenTamara Tuuminen
Tamara Tuuminen
We aimed to establish an etiology-based connection between the symptoms experienced by the occupants of a workplace and the presence in the building of toxic dampness microbiota. The occupants (5/6) underwent a medical examination and urine samples (2/6) were analyzed by LC-MS/MS for mycotoxins at two time-points. The magnitude of inhaled water was estimated. Building-derived bacteria and fungi were identified and assessed for toxicity. Separate cytotoxicity tests using human THP-1 macrophages were performed from the office’s indoor air water condensates. Office-derived indoor water samples (n = 4/4) were toxic to human THP-1 macrophages. Penicillium, Acremonium sensu lato, Aspergillus ochraceus group and Aspergillus section Aspergillus grew from the building material samples. These colonies were toxic in boar sperm tests (n = 11/32); four were toxic to BHK-21 cells. Mycophenolic acid, which is a potential immunosuppressant, was detected in the initial and follow-up urine samples of (2/2) office workers who did not take immunosuppressive drugs. Their urinary mycotoxin profiles differed from household and unrelated controls. Our study suggests that the presence of mycotoxins in indoor air is linked to the morbidity of the occupants. The cytotoxicity test of the indoor air condensate is a promising tool for risk assessment in moisture-damaged buildings.

13 October 2022 in Current Research in Toxicology
Verified
Journal Article
Open access
MMMarika Mannerstrom
Marika Mannerstrom
MDMarketa DVORAKOVA
Marketa DVORAKOVA
LSLada Svobodova
Lada Svobodova
MRMarian Rucki
Marian Rucki
FKFilip Kotal
Filip Kotal
THTuula Heinonen
Tuula Heinonen
• New approach methods were used to assess the hazard of indoor air condensates. • Individual chemicals could not be detected in the condensates. • Indoor air hazard was demonstrable in biological assays indicating cumulative effect.

1 December 2020 in Applied In Vitro Toxicology
Verified
Journal Article
Open access
MMMarika Mannerstrom
Marika Mannerstrom
TTTarja Toimela
Tarja Toimela
JAJonna Ahoniemi
Jonna Ahoniemi
AMAnthi-Styliani Makiou
Anthi-Styliani Makiou
THTuula Heinonen
Tuula Heinonen
Introduction: The impurities of the air inside the buildings and the resulting adverse health effects have become an increasing problem. Typically indoor air impurities are mixtures of many chemical substances at relative low concentrations. The toxicity of individual substances may be negligible, the mixture effect being the primary cause for toxicity and the potential adverse health effects. Standardized screening methods for identifying the health hazard are lacking. The aim of this study was, by using conventional cytotoxicity/cell viability assays, to investigate whether indoor air cytotoxicity can be detected from water samples condensed from indoor air. Materials and Methods: The cytotoxicity of 712 water samples condensed from indoor air was investigated. First, 24 samples were tested in four different cell types (human bronchial epithelial cells, BJ fibroblasts, Tohoku Hospital Pediatric-1 [THP-1] monocytes, and THP-1 macrophages) using neutral red uptake and water-soluble tetrazolium salt 1 (WST-1) assays. Thereafter, 688 samples were tested using THP-1 macrophage/WST-1 assay. All samples were tested at 10% sample concentration, 56 samples were also tested at 25% concentration to see dose–response effects. Results: THP-1 macrophage/WST-1 assay was the most reproducible method for assessing indoor air cytotoxicity. The adverse effects of indoor air samples on THP-1 cells ranged from ca. 33% loss in cell viability to ca. 17% increase in mitochondrial activity (“cell stress”). Indoor air samples from 75% sampling sites where people reported health symptoms caused adverse effects in THP-1 macrophage/WST-1 assay. Conclusions: The assessment of indoor air cytotoxicity using water samples condensed from the indoor air and THP-1 macrophage/WST-1 assay provides a novel and practical biological approach for investigating indoor air quality. This method does not replace existing methods, but supplements them and provides a fast and cheap alternative for the first-stage screening for recognizing poor indoor air regardless of its source.

1 November 2020 in Regulatory Toxicology and Pharmacology
Verified
Journal Article
Closed access
LSL. Svobodova
L. Svobodova
MDMarketa DVORAKOVA
Marketa DVORAKOVA
MRMarian Rucki
Marian Rucki
KKK. Kejlova
K. Kejlova
HKHelena Kandarova
Helena Kandarova
THT. Heinonen
T. Heinonen