Treatment of Robin sequence is often either invasive or of unproven effectiveness. The pre-epiglottic baton plate (PEBP) is a well-studied alternative, yet is not widely applied internationally. We report on a prospective 3-center cohort study investigating this treatment. Based on an agreed protocol, parents of infants with Robin sequence referred to participating centers were offered enrollment, which involved taking a maxillary cast followed by endoscopy to fit the plate and sleep studies to monitor its effectiveness. Recordings were centrally analyzed by sleep specialists blinded to timing and center. Primary outcome was the mixed-obstructive apnea index, defined as the number of such apneas/h of sleep; secondary outcomes included the desaturation index to <80% pulse oximeter saturation and weight gain. Of 75 infants referred, 49 could be included; 1 center failed to perform appropriate sleep studies. Within a mean hospitalization of 3 weeks, the mixed-obstructive apnea index decreased (median; interquartile range) from 15.9 (6.3–31.5) to 2.3 (1.2–5.4); it decreased further to 0.7 (0.1–2.4) in the 32 infants who had a successful 3-month follow-up sleep study performed. The desaturation index normalized (from 0.38 (0–2.7) to 0.0 (0–0.1)). Mean standard deviation score for weight remained unchanged between admission and follow-up, while the proportion of tube-fed infants decreased from 74 to 14%. This prospective multi-center cohort study confirms retrospective audits on the effectiveness of PEBP treatment in improving upper airway obstruction and feeding problems, the main clinical problems of infants with Robin sequence. International collaboration is required to compare this with other treatment approaches. Number NCT02266043 , Registered 30/09/2014; registered partially retrospectively.
Background: There is increasing evidence that intrauterine environment and, consequently, growth in utero have both immediate and far-reaching consequences for health. Neonatal body composition might be a more sensitive marker of intrauterine environment and neonatal adiposity than birth weight and could serve as a predictor for non-communicable diseases later in life. Methods: To perform a systematic literature review on neonatal body composition determined by air displacement plethysmography in healthy infants. The systematic review was performed using the search terms “air displacement plethysmography”, “infant” and “newborn” in Pubmed. Data are displayed as mean (Standard deviation). Results: Fourteen studies (including n = 6231 infants) using air displacement plethysmography fulfilled inclusion criteria for meta-analysis. In these, weighted mean body fat percentage was 10.0 (4.1) % and weighted mean fat free mass was 2883 (356) g in healthy term infants. Female infants had a higher body fat percentage (11.1 (4.1) % vs. 9.6 (4.0) %) and lower fat free mass (2827 (316) g vs. 2979 (344) g). In the Caucasian subpopulation (n = 2202 infants) mean body fat percentage was 10.8 (4.1), whereas data for reference values of other ethnic groups are still sparse. Conclusions: Body composition varies depending on gender and ethnicity. These aggregated data may serve as reference for body composition in healthy, term, singletons at least for the Caucasian subpopulation.
Feeding breast milk is associated with reduced morbidity and mortality, as well as improved neurodevelopmental outcome but does not meet the high nutritional requirements of preterm infants. Both plasma and urinary urea concentrations represent amino acid oxidation and low concentrations may indicate insufficient protein supply. This study assesses the effect of different levels of enteral protein on plasma and urinary urea concentrations and determines if the urinary urea-creatinine ratio provides reliable information about the protein status of preterm infants. Sixty preterm infants (birthweight < 1500 g; gestational age < 32 weeks) were enrolled in a randomized controlled trial and assigned to either a lower-protein group (median protein intake 3.7 g/kg/d) or a higher-protein group (median protein intake 4,3 g/kg/d). Half the patients in the higher-protein group received standardized supplementation with a supplement adding 1.8 g protein/100 ml milk, the other half received individual supplementation depending on the respective mother’s milk macronutrient content. Plasma urea concentration was determined in two scheduled blood samples (BS1; BS2); urinary urea and creatinine concentrations in weekly spot urine samples. The higher-protein group showed higher plasma urea concentrations in both BS1 and BS2 and a higher urinary urea-creatinine-ratio in week 3 and 5–7 compared to the lower-protein group. In addition, a highly positive correlation between plasma urea concentrations and the urinary urea-creatinine-ratio (p < 0.0001) and between actual protein intake and plasma urea concentrations and the urinary urea-creatinine-ratio (both p < 0.0001) was shown. The urinary urea-creatinine-ratio, just like plasma urea concentrations, may help to estimate actual protein supply, absorption and oxidation in preterm infants and, additionally, can be determined non-invasively. Further investigations are needed to determine reliable cut-off values of urinary urea concentrations to ensure appropriate protein intake. Clinicaltrials.gov; NCT01773902 registered 15 January 2013, retrospectively registered.
Background: During pregnancy, a variety of factors can influence fetal growth and development. Intrauterine growth may impact on later life and health. Neonatal body composition may be a more sensitive marker for the intrauterine environment than established anthropometric parameters at birth.Methods: To study neonatal body composition determined by air displacement plethysmography in healthy, term singletons as national reference data, and to establish factors impacting on neonatal body composition in this population. This prospective cross-sectional observational study included 271 healthy, full-term, singletons born between June 2014 and July 2015. Body composition was measured within 96 h of birth using air displacement plethysmography.Results: Median (Q1, Q2) fat mass / total body mass (BF%) in German singletons was 10.8% (7.7–13.4) and fat free mass (FFM) 2843 g (2606–3099). Female infants had significantly increased BF% compared to male infants (11.2% (8.7–14.0) vs. 9.6% (7.2–12.1)). On multiple regression analysis, BF% and fat mass increased with female gender, maternal pre-pregnancy body mass index, non-smoking mother and parity, whereas FFM increased with male gender and increasing gestational age at birth. Gestational weight gain category, birth mode, and postnatal age at measurement were not associated with BF%, FFM or fat mass.Conclusions: We generated BF% and FFM centiles for healthy, term, singletons born in Germany; these are similar to those found in other European countries. Infant body composition at birth was associated with modifiable (pre-pregnancy body mass index, smoking), and given factors (gender, gestational age at birth, parity).
Breast milk does not meet the nutritional needs of preterm infants, necessitating fortification. Breast milk is particularly variable in protein content, hence standardized (fixed dosage) supplementation results in inadequate supply. This was a secondary analysis of 589 breast milk protein content measurements of 51 mothers determined by mid-infrared spectroscopy during a clinical trial of higher versus lower protein supplementation in very low birth weight infants. Mothers (and breast milk samples) were divided into a test (41 mothers) and a validation cohort (10 mothers). In the test cohort, the decrease in protein content by day of lactation was modeled resulting in the breast milk-equation (BME)). In the validation cohort, five supplementation strategies to optimize protein supply were compared: standardized supplementation (adding 1.0 g (S1) or 1.42 g protein/100 mL (S2)) was compared with ‘adapted’ supplementation, considering variation in protein content (protein content according to Gidrewicz and Fenton (A1), to BME (A2) and to BME with adjustments at days 12 and 26 (A3)). S1 and S2 achieved 5% and 24% of adequate protein supply, while the corresponding values for A1–A3 were 89%, 96% and 95%. Adapted protein supplementation based on calculated breast milk protein content is easy, non-invasive, inexpensive and improves protein supply compared to standardized supplementation.