Chunlei Li

Dr. Chunlei Li

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2013 in Materials Characterization
Verified
Journal Article
Closed access
JCJ. Cao
J. Cao
Xiaoguo SongXiaoguo Song
Xiaoguo Song
CLChunlei Li
Chunlei Li
LZL.Y. Zhao
L.Y. Zhao
JFJiao Feng
Jiao Feng

5 January 2024 in Physica Scripta
Verified
Journal Article
Open access
PDF file
YSYiping Sun
Yiping Sun
DQDesheng Qu
Desheng Qu
QWQiaohua Wu
Qiaohua Wu
CLChunlei Li
Chunlei Li
A plasmonic sensor is proposed, comprising a metal–insulator–metal (MIM) straight waveguide and a ring cavity with one stub (RCS). Using the finite element method, its transport properties are simulated and systematically analyzed. By optimizing the structure parameters, the sensor obtains the maximum sensitivity (S) of 2010 nm/RIU and the maximum figure of merit (FOM) of 49219.04 RIU−1. It demonstrates a sensing resolution (SR) of 4.98 × 10−7 RIU in the detection of refractive index variation. Based on the optimized parameters, temperature sensing is investigated utilizing Polydimethylsiloxane (PDMS) as the temperature-sensitive medium, and the temperature sensitivity is found to be −0.90 nm/°C. In addition, multiple independently tunable resonances are achieved by adding a ring cavity (RC) above the straight waveguide. This derived structure enables the simultaneous detection of electrolyte samples (Na+ and K+) in blood with bio-sensing sensitivities reaching 0.1833 nm·dL/mg and 0.2 nm·dL/mg. These results have directive significance for the development of multifunctional and ultra-compact plasmonic sensor.

31 March 2014 in Journal of Modern Optics
Verified
Journal Article
Closed access
CLChunlei Li
Chunlei Li
DQDawei Qi
Dawei Qi
JXJiangbo Xin
Jiangbo Xin
FHFengyou Hao
Fengyou Hao
We propose metal-insulator-metal (MIM) plasmonic waveguide, in which metal is aluminum-doped zinc oxide (AZO) and insulator is air. The real part of relative dielectric constant is negative that is similar to the metal. Therefore, we call the AZO as metal. Owing to cutoff frequency of TM0 model for the MIM waveguide being slightly larger than 193.5 THz, the MIM waveguide shows obviously slow light effect around the commonly used telecom frequency. Exploiting the dispersion relationship of MIM waveguide, we analyze the effect of core layer width for the MIM waveguide on slow group velocity, second-, and third-order dispersion. The core layer width of MIM waveguide is determined to simultaneously realize obviously slow light effect and the lower distortion for the pulse with width 200 fs, which is confirmed by simulation used the finite-difference time-domain method. The MIM waveguide potentially applied in optical delay lines is easily fabricated.

1 October 2016 in Optics Communications
Verified
Journal Article
Closed access
CLChunlei Li
Chunlei Li
RSRunzhou Su
Runzhou Su
YWYuxiao Wang
Yuxiao Wang
XZXueru Zhang
Xueru Zhang

24 August 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
QWQiaohua Wu
Qiaohua Wu
YZYingqiu Zhang
Yingqiu Zhang
DQDesheng Qu
Desheng Qu
CLChunlei Li
Chunlei Li
A metal–insulator–metal (MIM) waveguide system consisting of a MIM waveguide, a ring cavity, and a semi-ring cavity is proposed. Using the finite element method, the transmission characteristics of the MIM waveguide system are discussed under the different geometry parameters. By detecting the resonance wavelength and varying the refractive index, the sensing performance of the MIM waveguide system is analyzed. The proposed structure can be used as a refractive index sensor with the maximum sensitivity of 2412 nm/RIU. Due to isolating the ring cavity and semi-ring cavity, the independent tuning of double resonances can be realized by changing the refractive index of the insulator in the ring cavity or the semi-ring cavity. Benefiting from two independent refractive index sensing modes, the structure with two isolated resonators can realize the simultaneous measurement of glucose solution concentration and blood plasma concentration. The sensitivity of glucose solution sensing in the ring cavity is 0.13133 nm/(g/L). Meanwhile, the blood plasma concentration detection in the semi-ring cavity is realized with the sensitivity of 0.358 nm/(g/L). The system with two isolated cavities has the potential to be used as an efficient nano sensor, which can achieve simultaneous measurement of two parameters.

1 September 2015 in Optics Communications
Verified
Journal Article
Closed access
CLChunlei Li
Chunlei Li
DQDawei Qi
Dawei Qi
YWYuxiao Wang
Yuxiao Wang
XZXueru Zhang
Xueru Zhang