Because of their high power density and compact size, permanent-magnet (PM) motors have been commonly used to drive rotary blood pumps (RBPs), which are focused on the treatment of end-stage heart failure or as the bridge to a heart transplant. In this paper, a bearingless PM motor has been proposed for axial blood pump applications. The finite-element method (FEM) is used to predict the electromagnetic characteristics of the designed motor with improved performance. Two topologies are investigated, namely the integral-slot and distributed-windings method and the fractional-slot and double-layer concentrated windings method. Both motors are analyzed and optimized. FEM reveals that, compared with the integral-slot motor, the fractional-slot motor offers significantly enhanced performance, including reduced cogging torque, improved back electromotive force (back EMF), and decreased magnetic flux leakage. Finally, hydraulic experiments have been conducted in a mock-circulation loop to validate the feasibility of the designed motor for an axial blood pump. The results show that the fractional-slot bearingless PM motor can drive the RBP to produce physiological blood flow with reasonable efficiency.
In this paper, the cavitation characteristics of centrifugal blood pumps under variable speeds were studied by using ANSYS-CFX and MATLAB software. The study proposed a multi-scale model of the “centrifugal blood pump—left heart blood circulation”, and analyzed the cavitation characteristics of the centrifugal blood pump. The results showed that the cavitation in the impeller first appeared near the hub at the inlet of the impeller. As the inlet pressure decreased, the cavitation gradually strengthened and the bubbles gradually developed in the outlet of the impeller. The cavitation intensity increased with the increase of impeller speed. The curve of the variable speeds of the centrifugal blood pump in the optimal auxiliary state was obtained, which could effectively improve the aortic pressure and flow. In variable speeds, due to the high aortic flow and pressure during the ejection period, the sharp increases in speeds led to cavitation. The results could provide a guidance for the optimal design of the centrifugal blood pump.
Based on the nonlinear relationship between heart rate and stroke volume, a flow model of left ventricular circulation was improved, and a variable-speed blood-pump control strategy based on heart-rate feedback was proposed. The control strategy was implemented on a system combining the rotary blood pump and blood circulation models of heart failure. The aortic flow of a healthy heart at different heart rates was the desired control goal. Changes in heart rate were monitored and pump speed was adjusted so that the output flow and aortic pressure of the system would match a normal heart in real time to achieve the best auxiliary state. After simulation with MATLAB, the cardiac output satisfied the ideal perfusion requirements at different heart rates, and aortic pressure demonstrated lifting and had good pulsatile performance when a variable-speed blood pump was used. The coupled model reflected the relationship between hemodynamic parameters at different heart rates with the use of the variable-speed blood pump, providing a theoretical basis for the blood-pump-assisted treatment of heart failure and the design of physiological control strategies.
1 October 2005 in Progress in Natural Science: Materials International
A quantitative evaluation of shear stress-related hemolysis in centrifugal blood pumps with different impeller designs has been investigated. Computational fluid dynamics (CFD) is applied to track the shear stress history of the streamlines of red cells. The power law model of the relations among the hemolysis, shear stress and exposure time is used to evaluate the hemolysis in the pumps. hemolysis tests are also conducted to verify the estimations. Both the estimations and experimentally measured hemolysis levels show that the hemolysis in the streamlined impeller pump developed by the authors is lower than the pump with straight-vane under the same boundary conditions. The approach is proved to be acceptable and practical to predict hemolysis levels of blaad pumps.
Implanting rotary blood pumps (RBPs) has become the principal treatment for patients suffering from severe heart failure. There are still many challenges to address for RBP control systems. These problems include meeting the patient’s physiological perfusion, eliminating postoperative complications, as well as debugging the patient’s physiological control system (automatically and indiscriminately). This paper proposes a non-invasive adaptive control system based on the Frank–Starling-like mechanism (NAC-FSL) to solve these problems. This control system uses the motor speed of the rotary blood pump as the only input variable, and the pump flow was estimated by the motor speed for achieving non-invasive detection. Simultaneously, a cardiovascular reference model was developed to provide an appropriate real-time preload for heart failure patients. The Frank–Starling-like control baseline was tracked to obtain the desired reference average pump flow by using the preload. Avoiding suction was done by adopting the control baseline (CLn), which included a flat slope under a high preload. Moreover, the NAC-FSL system could potentially unload the left ventricle and provide a higher pump flow with a smaller error during the exercise state, as compared to the CSC system. Finally, the K value indicating the preload sensitivity in the NAC-FSL controller was optimized to meet the perfusion needs according to the hemodynamic parameters.