Xiaojun Tang

Dr. Xiaojun Tang

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2020 in Spectroscopy Letters
Verified
Journal Article
Closed access
FZFeng Zhang
Feng Zhang
XTXiaojun Tang
Xiaojun Tang
ATAngxin Tong
Angxin Tong
BWBin Wang
Bin Wang
JWJingwei Wang
Jingwei Wang
JWJie Wang
Jie Wang
Baseline wander is a common problem in analysis with Fourier Transform Infrared Spectrometer (FTIR). And it is necessary to correct baseline drift for further quantitative and qualitative analysis. Several baseline correction algorithms based on penalized least squares have been proposed. However, these methods are usually used in noise-free or low-noise environments. In this paper, a novel algorithm named adaptive smoothness parameter penalized least squares was proposed. The smoothness parameters were set by user at first. Then, the smoothness parameter was updated iteratively according to the difference between the original spectrum and fitted baseline. When the iteration reaches the termination condition, the fitted baseline can be obtained. In the end of the paper, experimental results on simulated spectra and measured infrared spectra of methane were given. The simulated spectra results demonstrate that the proposed method has better performance than existing methods, especially when the spectra contain high noise. The results of infrared spectra confirm that the proposed method has good performance and can be applied to correct spectral baseline accurately.

1 June 2020 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Open access
ATAngxin Tong
Angxin Tong
XTXiaojun Tang
Xiaojun Tang
FZFeng Zhang
Feng Zhang
BWBin Wang
Bin Wang
In this study, we mainly focused on predictable regularities of the red shift of ultraviolet spectra for β-phenylethylamine (PEA), NaCl and NaOH in aqueous solution. The absorption peaks of the UV spectra near 191 nm of NaCl, NaOH and PEA in aqueous solution moved in the direction of a red shift while the molar absorption coefficient at the peak increased regularly with the increasing solution concentration. These shifts were obtained for solutions with concentrations ranging from 3.68 to 1000 mmol/L for NaCl, from 0.762 to 2000 mmol/L for NaOH, and from 0.0515 to 8.91 mmol/L for PEA. The plots of the logarithm of the solution concentration for NaCl and PEA versus the absorbance at 191 nm and at the peak were linear, and the plots of the logarithm of the solution concentration for NaCl and PEA versus the wavelength at the peak (shifted from 191 nm) were also linear. In addition, the plots of the logarithm of the solution concentration for NaOH that ranged from 0.762 to 1.96 mmol/L versus the absorbance at 191 nm and at the peak were linear as well as the plots of the logarithm of the solution concentration for NaOH that ranged from 1.96 to 2000 mmol/L versus the wavelength at the peak. The slopes of the absorbance at 191 nm of PEA, NaCl and NaOH were somewhat similar to the absorbance at the peak separately, whereas the slopes of the wavelengths at the peak were different from them. Finally, in order to obtain the predictable regularity of the red shift of the UV spectrum for the mixture, 22 ternary mixtures were prepared. The results indicate that the inhibiting effect of hydroxide ions (OH-) caused the wavelength near 206 nm to remain unchanged when the solution concentration of NaOH in the mixture was more than 0.762 mmol/L.

3 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
FZFeng Zhang
Feng Zhang
XTXiaojun Tang
Xiaojun Tang
ATAngxin Tong
Angxin Tong
BWBin Wang
Bin Wang
JWJingwei Wang
Jingwei Wang
Baseline drift spectra are used for quantitative and qualitative analysis, which can easily lead to inaccurate or even wrong results. Although there are several baseline correction methods based on penalized least squares, they all have one or more parameters that must be optimized by users. For this purpose, an automatic baseline correction method based on penalized least squares is proposed in this paper. The algorithm first linearly expands the ends of the spectrum signal, and a Gaussian peak is added to the expanded range. Then, the whole spectrum is corrected by the adaptive smoothness parameter penalized least squares (asPLS) method, that is, by turning the smoothing parameter λ of asPLS to obtain a different root-mean-square error (RMSE) in the extended range, the optimal λ is selected with minimal RMSE. Finally, the baseline of the original signal is well estimated by asPLS with the optimal λ. The paper concludes with the experimental results on the simulated spectra and measured infrared spectra, demonstrating that the proposed method can automatically deal with different types of baseline drift.

8 April 2024 in ACS Catalysis
Verified
Journal Article
Closed access
MYMengying Yang
Mengying Yang
JWJingjing Wu
Jingjing Wu
YLYue Li
Yue Li
HPHongyu Pan
Hongyu Pan
HCHongbo Cui
Hongbo Cui
XTXiaojun Tang
Xiaojun Tang

17 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
XTXiaojun Tang
Xiaojun Tang
WWWenjing Wang
Wenjing Wang
XZXuliang Zhang
Xuliang Zhang
EWErzhen Wang
Erzhen Wang
XLXuanjiannan Li
Xuanjiannan Li
To address the problem of on-line dissolved gas analysis (DGA) of a power transformer, a Fourier transform infrared (FT-IR) spectrometer was used to develop an analysis instrument. Carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), ethane (C2H6), ethylene (C2H4) and acetylene (C2H2) were the analytes for the FT-IR spectrometer while propane (C3H8), propylene (C3H6), propyne (C3H4), n-butane (n-C4H10) and iso-butane (iso-C4H10) were the interferents, which might exist in the dissolved gas but are not currently used as analytes for detecting an internal fault. The instrument parameters and analysis approach are first introduced. Specifically, an absorption spectra reading approach by switching two cone-type gas cells into separate light-paths was presented for reducing the effects of gas in the gaps between gas cells and spectrometers, scanning the background spectrum without clearing the sample cell, and increasing the dynamics. Then, the instrument was tested with a standard gas mixture that was extracted from insulation oil in a power transformer. The testing results show that the detection limit of every analyte component is lower than 0.1 μL/L, and the detection limits of all analytes meet the detection requirements of oil-dissolved gas analysis, which means that the FT-IR spectrometer may be an ideal instrument due to its benefits, such as being maintenance-free and having a high stability.

3 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
FZFeng Zhang
Feng Zhang
XTXiaojun Tang
Xiaojun Tang
LLLin Li
Lin Li
The spectrum scanned by a Fourier transform spectrometer (FTIR) often has a baseline drift. However, baseline distortion rarely occurs in a laboratory owing to the insignificant effects of environmental vibrations and electromagnetic factors. Even if it occurs, the distorted spectrum can be manually eliminated. However, in a complex environment, especially after the long-term operation of a spectrometer, the scanned spectrum may be distorted to different degrees. Herein, the origins of spectral baseline drifts and distortions are analyzed and simulated using MATLAB; furthermore, a baseline correction method based on the baseline-type model is proposed. The results of experiments performed on the methane spectrum confirm that the proposed method outperformed the improved modified multi-polynomial fitting and iterative averaging methods.