Robert Stewart

Dr. Robert Stewart


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2011 in Radiation Research
Verified
Journal Article
Closed access
PDF file
RSRobert Stewart
Robert Stewart
VYVictor K. Yu
Victor K. Yu
ALEXANDROS GEORGAKILASALEXANDROS GEORGAKILAS
ALEXANDROS GEORGAKILAS
CKConstantinos Koumenis
Constantinos Koumenis
JPJoo Han Park
Joo Han Park
DCDavid J. Carlson
David J. Carlson
Radiation quality and cellular oxygen concentration have a substantial impact on DNA damage, reproductive cell death and, ultimately, the potential efficacy of radiation therapy for the treatment of cancer. To better understand and quantify the effects of radiation quality and oxygen on the induction of clustered DNA lesions, we have now extended the Monte Carlo Damage Simulation (MCDS) to account for reductions in the initial lesion yield arising from enhanced chemical repair of DNA radicals under hypoxic conditions. The kinetic energy range and types of particles considered in the MCDS have also been expanded to include charged particles up to and including 56Fe ions. The induction of individual and clustered DNA lesions for arbitrary mixtures of different types of radiation can now be directly simulated. For low-linear energy transfer (LET) radiations, cells irradiated under normoxic conditions sustain about 2.9 times as many double-strand breaks (DSBs) as cells irradiated under anoxic conditions. New experiments performed by us demonstrate similar trends in the yields of non-DSB (Fpg and Endo III) clusters in HeLa cells irradiated by γ rays under aerobic and hypoxic conditions. The good agreement among measured and predicted DSBs, Fpg and Endo III cluster yields suggests that, for the first time, it may be possible to determine nucleotide-level maps of the multitude of different types of clustered DNA lesions formed in cells under reduced oxygen conditions. As particle LET increases, the MCDS predicts that the ratio of DSBs formed under normoxic to hypoxic conditions by the same type of radiation decreases monotonically toward unity. However, the relative biological effectiveness (RBE) of higher-LET radiations compared to 60Co γ rays (0.24 keV/μm) tends to increase with decreasing oxygen concentration. The predicted RBE of a 1 MeV proton (26.9 keV/μm) relative to 60Co γ rays for DSB induction increases from 1.9 to 2.3 as oxygen concentration decreases from 100% to 0%. For a 12 MeV 12C ion (681 keV/μm), the ‵predicted RBE for DSB induction increases from 3.4 (100% O2) to 9.8 (0% O2). Estimates of linear-quadratic (LQ) cell survival model parameters (α and β) are closely correlated to the Monte Carlo-predicted trends in DSB induction for a wide range of particle types, energies and oxygen concentrations. The analysis suggests α is, as a first approximation, proportional to the initial number of DSBs per cell, and β is proportional to the square of the initial number of DSBs per cell. Although the reported studies provide some evidence supporting the hypothesis that DSBs are a biologically critical form of clustered DNA lesion, the induction of Fpg and Endo III clusters in HeLa cells irradiated by γ rays exhibits similar trends with oxygen concentration. Other types of non-DSB cluster may still play an important role in reproductive cell death. The MCDS captures many of the essential trends in the formation of clustered DNA lesions by ionizing radiation and provides useful information to probe the multiscale effects and interactions of ionizing radiation in cells and tissues. Information from Monte Carlo simulations of cluster induction may also prove useful for efforts to better exploit radiation quality and reduce the impact of tumor hypoxia in proton and carbon-ion radiation therapy.

9 October 2015 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
RSRobert Stewart
Robert Stewart
SSSeth W Streitmatter
Seth W Streitmatter
DADavid C Argento
David C Argento
CKCharles Kirkby
Charles Kirkby
JGJohn T Goorley
John T Goorley
GSGeorge A Sandison
George A Sandison
To account for particle interactions in the extracellular (physical) environment, information from the cell-level Monte Carlo damage simulation (MCDS) for DNA double strand break (DSB) induction has been integrated into the general purpose Monte Carlo N-particle (MCNP) radiation transport code system. The effort to integrate these models is motivated by the need for a computationally efficient model to accurately predict particle relative biological effectiveness (RBE) in cell cultures and in vivo . To illustrate the approach and highlight the impact of the larger scale physical environment (e.g. establishing charged particle equilibrium), we examined the RBE for DSB induction (RBE DSB ) of x-rays, 137 Cs γ -rays, neutrons and light ions relative to γ -rays from 60 Co in monolayer cell cultures at various depths in water. Under normoxic conditions, we found that 137 Cs γ -rays are about 1.7% more effective at creating DSB than γ -rays from 60 Co (RBE DSB = 1.017) whereas 60–250 kV x-rays are 1.1 to 1.25 times more efficient at creating DSB than 60 Co. Under anoxic conditions, kV x-rays may have an RBE DSB up to 1.51 times as large as 60 Co γ -rays. Fission neutrons passing through monolayer cell cultures have an RBE DSB that ranges from 2.6 to 3.0 in normoxic cells, but may be as large as 9.93 for anoxic cells. For proton pencil beams, Monte Carlo simulations suggest an RBE DSB of about 1.2 at the tip of the Bragg peak and up to 1.6 a few mm beyond the Bragg peak. Bragg peak RBE DSB increases with decreasing oxygen concentration, which may create opportunities to apply proton dose painting to help address tumor hypoxia. Modeling of the particle RBE for DSB induction across multiple physical and biological scales has the potential to aid in the interpretation of laboratory experiments and provide useful information to advance the safety and effectiveness of hadron therapy in the treatment of cancer.

30 December 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
YTYolanda D Tseng
Yolanda D Tseng
SMShadonna M. Maes
Shadonna M. Maes
GKGregory Kicska
Gregory Kicska
PSPatricia Sponsellor
Patricia Sponsellor
ETErik Traneus
Erik Traneus
JSJatinder Saini
Jatinder Saini
Background: Existing pencil beam analytical (PBA) algorithms for proton therapy treatment planning are not ideal for sites with heterogeneous tissue density and do not account for the spatial variations in proton relative biological effectiveness (vRBE). Using a commercially available Monte Carlo (MC) treatment planning system, we compared various dosimetric endpoints between proton PBA, proton MC, and photon treatment plans among patients with mediastinal lymphoma. Methods: Eight mediastinal lymphoma patients with both free breathing (FB) and deep inspiration breath hold (DIBH) CT simulation scans were analyzed. The original PBA plans were re-calculated with MC. New proton plans that used MC for both optimization and dose calculation with equivalent CTV/ITV coverage were also created. A vRBE model, which uses a published model for DNA double strand break (DSB) induction, was applied on MC plans to study the potential impact of vRBE on cardiac doses. Comparative photon plans were generated on the DIBH scan. Results: Re-calculation of FB PBA plans with MC demonstrated significant under coverage of the ITV V99 and V95. Target coverage was recovered by re-optimizing the PT plan with MC with minimal change to OAR doses. Compared to photons with DIBH, MC-optimized FB and DIBH proton plans had significantly lower dose to the mean lung, lung V5, breast tissue, and spinal cord for similar target coverage. Even with application of vRBE in the proton plans, the putative increase in RBE at the end of range did not decrease the dosimetric advantages of proton therapy in cardiac substructures. Conclusions: MC should be used for PT treatment planning of mediastinal lymphoma to ensure adequate coverage of target volumes. Our preliminary data suggests that MC-optimized PT plans have better sparing of the lung and breast tissue compared to photons. Also, the potential for end of range RBE effects are unlikely to be large enough to offset the dosimetric advantages of proton therapy in cardiac substructures for mediastinal targets, although these dosimetric findings require validation with late toxicity data.

1 June 2018 in International Journal of Particle Therapy
Verified
Journal Article
Open access
RSRobert Stewart
Robert Stewart
The specific types and numbers of clusters of DNA lesions, including both DNA double-strand breaks (DSBs) and non-DSB clusters, are widely considered 1 of the most important initiating events underlying the relative biological effectiveness (RBE) of the light ions of interest in the treatment of cancer related to megavoltage x-rays and 60Co γ-rays. This review summarizes the categorization of DNA damage, reviews the underlying mechanisms of action by ionizing radiation, and quantifies the general trends in DSB and non-DSB cluster formation by light ions under normoxic and anoxic conditions, as predicted by Monte Carlo simulations that reflect the accumulated evidence from decades of research on radiation damage to DNA. The significance of the absolute and relative numbers of clusters and the local complexity of DSB and non-DSB clusters are discussed in relation to the formation of chromosome aberrations and the loss of cell reproductive capacity. Clinical implications of the dependence of DSB ind...

1 May 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
GMGregory B Moffitt
Gregory B Moffitt
RSRobert Stewart
Robert Stewart
GSGeorge A Sandison
George A Sandison
JGJohn T Goorley
John T Goorley
DADavid C Argento
David C Argento
GLGeorge E Laramore
George E Laramore
The University of Washington (UW) Clinical Neutron Therapy System (CNTS), which generates high linear energy transfer fast neutrons through interactions of 50.5 MeV protons incident on a Be target, has depth-dose characteristics similar to 6 MV x-rays. In contrast to the fixed beam angles and primitive blocking used in early clinical trials of neutron therapy, the CNTS has a gantry with a full 360° of rotation, internal wedges, and a multi-leaf collimator (MLC). Since October of 1984, over 3178 patients have received conformal neutron therapy treatments using the UW CNTS. In this work, the physical and dosimetric characteristics of the CNTS are documented through comparisons of measurements and Monte Carlo simulations. A high resolution computed tomography scan of the model 17 ionization chamber (IC-17) has also been used to improve the accuracy of simulations of the absolute calibration geometry. The response of the IC-17 approximates well the kinetic energy released per unit mass (KERMA) in water for neutrons and photons for energies from a few tens of keV up to about 20 MeV. Above 20 MeV, the simulated model 17 ion chamber response is 20%–30% higher than the neutron KERMA in water. For CNTS neutrons, simulated on- and off-axis output factors in water match measured values within ~2% ± 2% for rectangular and irregularly shaped field with equivalent square areas ranging in a side dimension from 2.8 cm to 30.7 cm. Wedge factors vary by less than 1.9% of the measured dose in water for clinically relevant field sizes. Simulated tissue maximum ratios in water match measured values within 3.3% at depths up to 20 cm. Although the absorbed dose for water and adipose tissue are within 2% at a depth of 1.7 cm, the absorbed dose in muscle and bone can be as much as 12 to 40% lower than the absorbed dose in water. The reported studies are significant from a historical perspective and as additional validation of a new tool for patient quality assurance and as an aid in ongoing efforts to clinically implement advanced treatment techniques, such as intensity modulated neutron therapy, at the UW.

15 October 2020 in Cells
Verified
Journal Article
Open access
SSSeth Streitmatter
Seth Streitmatter
RSRobert Stewart
Robert Stewart
GMGregory Moffitt
Gregory Moffitt
TJTatjana Jevremovic
Tatjana Jevremovic
Accurate dosimetry and determination of the biological effectiveness of boron neutron capture therapy (BNCT) is challenging because of the mix of different types and energies of radiation at the cellular and subcellular levels. In this paper, we present a computational, multiscale system of models to better assess the relative biological effectiveness (RBE) and compound biological effectiveness (CBE) of several neutron sources as applied to BNCT using boronophenylalanine (BPA) and a potential monoclonal antibody (mAb) that targets HER-2-positive cells with Trastuzumab. The multiscale model is tested against published in vitro and in vivo measurements of cell survival with and without boron. The combined dosimetric and radiobiological model includes an analytical formulation that accounts for the type of neutron source, the tissue- or cancer-specific dose–response characteristics, and the microdistribution of boron. Tests of the model against results from published experiments with and without boron show good agreement between modeled and experimentally determined cell survival for neutrons alone and in combination with boron. The system of models developed in this work is potentially useful as an aid for the optimization and individualization of BNCT for HER-2-positive cancers, as well as other cancers, that can be targeted with mAb or a conventional BPA compound.