Phoonthawee Saetear

Dr. Phoonthawee Saetear

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in Materials Chemistry Frontiers
Verified
Journal Article
Closed access
PDF file
BTBunyaporn Todee
Bunyaporn Todee
TCThreeraphat Chutimasakul
Threeraphat Chutimasakul
KJKritanan Junthod
Kritanan Junthod
ADAndrew Docker
Andrew Docker
PSPhoonthawee Saetear
Phoonthawee Saetear
TBThanthapatra Bunchuay
Thanthapatra Bunchuay
The synthesis and post-synthetic modification of a novel tosylate-functionalized hyper-crosslinked polymer (HCP) for the purpose of water remediation are reported. An FeCl3-catalyzed cross-linking reaction of a bis-tosylated arene monomer (M-OTs) gave a tosylate-substituted HCP precursor (P-OTs) in high yield. In contrast to halogenated monomers, the tosylate functional groups in M-OTs are inert under such polymerization conditions, allowing for facile chemical modification of P-OTsvia SN2, reduction, and oxidation reactions to afford a series of HCPs containing thioacetate (P-SAc), thiol (P-SH), and sulfonic acid (P-SO3H) functional groups. Characterized using a suite of techniques including FT-IR, elemental analysis, TGA, SEM, and BET, the sulfur-containing HCP series were investigated as organic pollutant extractant materials for contaminated water streams. Wherein it was demonstrated that the HCP series exhibited highly selective adsorption towards cationic species in aqueous solution operating in a considerable pH window and artificial sea and fresh water. Importantly, by virtue of strong electrostatic interactions, P-SO3H outperformed other HCPs in rapid and efficient methylene blue (MB) and paraquat (PQ) adsorption with impressive adsorption capacities (qmax) of 582.60 mg g−1 and 568.13 mg g−1, respectively.

27 October 2021 in Molecules
Verified
Journal Article
Open access
PDF file
PSPhoonthawee Saetear
Phoonthawee Saetear
NSNattinee Saechua
Nattinee Saechua
KSKamonthip Sereenonchai
Kamonthip Sereenonchai
This work presents, for the first time, a new sequential injection analysis (SIA) method to simultaneously analyze degree Brix, orthophosphate and pH in raw cane juice. These key parameters relate to price of harvested sugarcane and quality of cane juice for sugar production. The SIA system employed two detectors: the first detector is a diode-array spectrophotometer, equipped with a regular flow cell, for measurements of degree Brix and orthophosphate. Quantitative of degree Brix (°Bx; ca. % (w/w) sucrose) was based on manipulation of the schlieren effect at the interface between plugs of sample and water. Orthophosphate analysis was carried out based on the molybdenum blue method with significant reduction in consumption of the reagents. Compensation of the schlieren effect from sucrose for determination of orthophosphate was achieved by using a dual-wavelength spectrometric detection. Second detector is a pH-sensing device, called ion-selective field-effect transistors (ISFET). The ISFET is based on the current through the ISFET arising according to the H+ concentration in solution. Our developed SIA system provides linear calibration graphs fitting for purpose in analysis of sugarcane juice (pH: 0–14, °Bx: 1.0–7.0 and P2O5: 20–200 mg L−1). Simultaneous analysis of sugarcane juice for pH, °Bx and P2O5 is carried out within 5 min (12 sample per h). Precision of SIA system is acceptable (RSD < 3%). Our SIA system gave quantitative results insignificantly different, as compared with conventional methods for analysis of pH, °Bx and P2O5 in sugarcane juice.

18 May 2020 in Membranes
Verified
Journal Article
Open access
PDF file
ATAulia Ayuning Tyas
Aulia Ayuning Tyas
TSThitaporn Sonsa-Ard
Thitaporn Sonsa-Ard
KUKanchana Uraisin
Kanchana Uraisin
DNDuangjai Nacapricha
Duangjai Nacapricha
PSPhoonthawee Saetear
Phoonthawee Saetear
This study presents a simple flow-based system for the determination of the preservative agent sulfite in food and beverages. The standard method of conversion of sulfite ions into SO2 gas by acidification is employed to separate the sulfite from sample matrices. The sample is aspirated into a donor stream of sulfuric acid. A membrane gas–liquid separation unit, also called a ‘gas-diffusion (GD)’ unit, incorporating a polytetrafluoroethylene (PTFE) hydrophobic membrane allows the generated gas to diffuse into a stream of deionized water in the acceptor line. The dissolution of the SO2 gas leads to a change in the conductivity of water which is monitored by an in-line capacitively coupled contactless conductivity detector (C4D). The conductivity change is proportional to the concentration of sulfite in the sample. In this work, both clear (wine) and turbid (fruit juice and extracts of dried fruit) were selected to demonstrate the versatility of the developed method. The method can tolerate turbidity up to 60 Nephelometric Turbidity Units (NTUs). The linear range is 5–25 mg L−1 SO32− with precision <2% RSD. The flow system employs a peristaltic pump for propelling all liquid lines. Quantitative results of sulfite were statistically comparable to those obtained from iodimetric titration for the wine samples.

1 March 2022 in Analytical Sciences
Verified
Journal Article
Closed access
PDF file
NNNakarin Noirahaeng
Nakarin Noirahaeng
KUKanchana Uraisin
Kanchana Uraisin
PWPanwadee Wattanasin
Panwadee Wattanasin
PSPhoonthawee Saetear
Phoonthawee Saetear
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.

8 June 2023 in Analytica
Verified
Journal Article
Open access
PDF file
CPChirapha Prakobdi
Chirapha Prakobdi
PSPhoonthawee Saetear
Phoonthawee Saetear
This work presents the first development of an analytical turbidimetric method for the determination of legal alcohols in alcohol-based hand sanitizer products. A typical iodoform reaction is exploited to form a yellow product in the form of precipitates. An iodoform test shows a positive result as yellow precipitates in the presence of ethanol and isopropanol; therefore, the test can only be used to distinguish between methanol and those legal alcohols. In the presence of molecular iodine (I2) and a strong alkaline solution, the legal alcohol is converted to the corresponding carbonyl compound (i.e., ethanol to acetaldehyde, isopropanol to acetone). The susceptibility of this intermediate towards the reaction with hydroxide ions (strong alkaline condition) results in formations of yellow precipitation of iodoform (CHI3) and a water-soluble carboxylate salt in the solution. Therefore, this change allows for the detection of legal alcohols through either naked-eye observation (as semi-quantitative analysis) or a common benchtop/portable photometer/spectrophotometer (as quantitative analysis) by means of turbidimetric analysis. In this work, turbidimetry is employed, which is a useful alternative detection method in analytical practice, especially with colored samples in hand sanitizing products. This is because they can employ wavelengths at which the colored solution does not absorb light. As a result of our developed method, the calibration plots are in the range of 30 to 100% (v/v) for both ethanol and isopropanol. The limit of detection (LOD) (3SD of y-intercept/slope) was found to be 7.4% (v/v) ethanol and 6.5% (v/v) isopropanol. Direct analysis of the non-pretreatment of the sample is achieved. The results indicate that our new proposed analytical method is fit for purpose and valid to detect the legal alcohols in alcohol-based hand sanitizing products for both international and Thai regulations (at least 70% (v/v)). Our quantitative results were also comparable to a standard analytical method, such as the use of a gas chromatography-flame ionization detector (GC-FID). Our developed method and analytical operation could potentially be developed into a practically portable analysis.

23 February 2022 in Analytica
Verified
Journal Article
Open access
PDF file
CSChanakarn Sangsum
Chanakarn Sangsum
PSPhoonthawee Saetear
Phoonthawee Saetear
This work presents the first development of an all-steps-in-one test kit for the determination of paraquat in natural water, and vegetable and agricultural samples. A handheld photometer incorporated with a magnetic stirrer was used to complete the steps of extraction, mixing, and detection. Paraquat produces a blue free radical ion via a reduction with sodium dithionite in alkaline conditions. Sodium dithionite powder was investigated for the enhancement of reagent stability duration, which was added directly into sample solution that showed insignificant difference in sensitivity as compared with that of the solution format of sodium dithionite. The developed test kit showed good performance with the linear calibration of 0.5 to 10 mg L−1 with a high coefficient of determination (r2 = 0.9947). The lower limit of quantitation (LLOQ = 3SD of intercept per slope) carried out from the method using the handheld photometer was 0.50 mg L−1. The limit of detection (LOD) by naked eye was 0.30 mg L−1. The recovery study was acceptable in the range of 101–115%. Intraday (n = 3) and interday (n = 3) precision was less than 1%. On the basis of the significance test at the 95% confidence interval, quantitative results of the developed test kit agreed well with those from high-performance liquid chromatography (HPLC). To the best of our knowledge, this is the first report demonstrating an online extraction for vegetables incorporated into a test kit, applicable for on-site analysis. Single-point calibration based on the Beer–Lambert law also demonstrated the measurement of paraquat. In testing with a nominal standard solution of 5.00 mg L−1 paraquat, the reading concentration was 5.09 ± 0.03 mg L−1 paraquat (n = 20) with a K value of 0.0967 (close to the slope of multipoint calibration). This research is a direct benefit to agricultural products and the health of a population for the analysis of pesticides and herbicides.