This study aimed to compare the differences in radiological outcomes and complications between single- and multilevel anterior cervical discectomy and fusion (ACDF) by using a polyetheretherketone (PEEK) cage–plate fusion system. Fifty-seven patients who underwent ACDF via the PEEK cage–plate fusion system were enrolled and subjected to ≥6 months of follow-up. The patients were divided into 4 groups according to different cage–plate implantation levels: 1-level group (n = 17), 2-level group (n = 24), 3-level group (n = 12), and 4-level group (n = 4). Fusion time, changes in segment and global lordotic angle, subsidence rate, and changes in disc and adjacent segmental disc height were subjected to radiological evaluation. The fusion period of multilevel ACDF was longer than that of single-level ACDF. The fusion period of the 3-level (4.09 ± 0.94, P = .004) and 4-level (5.25 ± 0.89, P = .004) group was also significantly longer than that of the 1-level group. The mean lordotic angle in all of the groups was changed in the immediate postoperative period and in the final follow-up. The cage subsidence rates were 11.76% (2/17) in the 1-level group, 20.83% (5/24) in the 2-level group, and 2/12 (16.67%) in the 3-level group. No subsidence occurred in the 4-level groups. Changes in the lower adjacent segmental disc height were significantly increased in multilevel ACDF compared with those in single-level ACDF. Despite the longer fusion time, the outcomes of the proposed system were even better with the greater number of treatment levels by using PEEK cage–plate fusion system. Changes in the lower adjacent segmental disc height should also prolong follow-up duration to investigate the symptomatic adjacent segment degeneration in multilevel ACDF.
1 February 2018 in Journal of Clinical Neuroscience
This study aimed to verify the relationship between the number of fusion level and the risk of screw loosening by using cortical bone trajectory (CBT) screws in patients with lumbar degenerative disease. We retrospectively reviewed the serial plain radiograph images of lumbar degenerative disease patients who had undergone posterior fixation and fusion surgery with CBT from 2014. All included patients should have been followed-up with computed tomography scan or plain radiograph for at least 6 months after operation. We individually evaluated the prevalence of screw loosening according to each vertebral level. We also determined whether the number of screw fixation affected the prevalence of screw loosening and whether S1 fixation increased the risk of screw loosening. The screw-loosening rates were high at the S1 level. Moreover, although fixation involved to S1, the loosening rates evidently increased (Fisher exact test, P = .002∗∗). The screw-loosening rate was 6.56% in 2 level fusion. However, it increased with the number of fusion levels (3 level: 25.00%, 4 level: 51.16%, and 5 level: 62.50%). To investigate if the number of fusion level affected the S1 screw loosening, we classified the cohort of patients into either involving S1 (S1+ group) or not (S1– group) according to different fusion levels (Table 3). The screw loosening between 2 group in 2 (5.56% vs 6.98%) and 3 fusion level (26.32% vs 22.73%) did not exhibit any significant difference. Interestingly, significantly high screw loosening was found in 4 fusion level (60.00% vs 15.38%), indicating that the higher fusion level (4 level) can directly increase the risk of S1 screw loosening. Our data confirmed that the screw-loosening rate increases rate when long segment CBT fixation involves to S1. Therefore, in case of long-segment fixation by using CBT screw, surgeons should be aware of the fusion level of S1.
Background: Osteoporotic spinal fractures commonly occur in elderly patients with low bone mineral density. In these cases, percutaneous vertebroplasty or percutaneous kyphoplasty can provide significant pain relief and improve mobility. However, studies have reported both the recurrence of vertebral compression fractures at the index level after vertebroplasty and the development of new vertebral fractures at the adjacent level that occur without any additional trauma. Pedicle screw fixation combined with percutaneous vertebroplasty has been proposed as an effective procedure for addressing osteoporotic thoracolumbar fractures. However, in osteoporotic populations, pedicle screws can loosen, pullout, or migrate. Currently, the efficacy of cortical bone trajectory screw fixation for osteoporotic fractures remains unclear. Thus, we assessed the effects of using cortical bone trajectory instrumentation with vertebroplasty on patient outcomes. Method: We retrospectively reviewed data from 12 consecutively sampled osteoporotic thoracolumbar fracture patients who underwent cortical bone trajectory instrumentation with vertebroplasty. Patients were enrolled beginning in October 2015 and were followed for >24 months. Result: The average age was 74 years, and the average dual-energy x-ray absorptiometry T-score was −3.6. The average visual analog scale pain scores improved from 8 to 2.5 after surgery. The average blood loss was 36.25 mL. All patients regained ambulation and experienced reduced pain post-surgery. No recurrent fractures or instrument failures were recorded during follow-up. Conclusions: Our findings suggest that cortical bone trajectory instrumentation combined with percutaneous vertebroplasty may be a good option for treating osteoporotic thoracolumbar fractures, as it can prevent recurrent vertebral fractures or related kyphosis in sagittal alignment.
Purpose: This study aims to elucidate the radiological outcome after Cortical bone trajectory (CBT) screw fixation and whether dual-threaded (DT) screws should be used in the fusion surgery. Methods: 159 patients with degenerative lumbar disorder who had undergone midline lumbar inter-body fusion surgery by CBT screw-fixation technique (2014 to 2018). Patient subgroups were based on single-threaded (ST) or DT screw, fixation length, as well as whether fixation involved to sacrum level (S1). Serial dynamic plain films were reviewed and an appearance of a halo phenomenon between screw–bone interfaces was identified as a case of screw loosening. Results: 29 patients (39.7%) in ST group and 10 patients (11.6%) in DT group demonstrated a halo phenomenon (p < 0.0001 ****). After subgrouping with fixation length, the incidence rates of a halo phenomenon in each group were 11.1%:3% (ST-1L vs. DT-1L), 37%:13.8% (ST-2L vs. DT-2L), and 84.2%:23.5% (ST-3L vs. DT-3L). Among the 85 patients with a fixation involved in S1, 26 patients (52%) with single-threaded screw (STS group) and 8 patients (22.8%) with dual-threaded screw (DTS group) demonstrated a halo appearance (p = 0.0078 **). After subgrouping the fixation level, the incidence of a halo appearance in each group was 25%:0% (STS-1L vs. DTS-1L), 40.9%:26.3% (STS-2L vs. DTS-2L), and 87.5%: 30% (STS-3L vs. DTS-3L). Conclusion: Both fixation length and whether fixation involved to S1 contribute to the incidence of screw loosening, the data supports clinical evidence that DT screws had greater fixation strength with an increased fixative stability and lower incidence of screw loosening in CBT screw fixation compared with ST screws. Level of evidence: 2.