Mayank Nanavaty

Dr. Mayank Nanavaty

Brighton & Sussex University Hospitals NHS trust
+1
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2020 in Vision
Verified
Journal Article
Open access
PDF file
ZAZahra Ashena
Zahra Ashena
SMSundas Maqsood
Sundas Maqsood
SASyed Naqib Ahmed
Syed Naqib Ahmed
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
Tilt and decentration of intraocular lenses (IOL) may occur secondary to a complicated cataract surgery or following an uneventful phacoemulsification. Although up to 2–3° tilt and a 0.2–0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance and subsequently, the patients’ satisfaction. This negative impact does not affect various types of IOLs equally. In this paper we review the methods of measuring IOL tilt and decentration and focus on the effect of IOL tilt and decentration on visual function, in particular visual acuity, dysphotopsia, and wavefront aberrations. Our review found that the methods to measure the IOL displacement have significantly evolved and the available studies have employed different methods in their measurement, while comparability of these methods is questionable. There has been no universal reference point and axis to measure the IOL displacement between different studies. A remarkably high variety and brands of IOLs are used in various studies and occasionally, opposite results are noticed when two different brands of a same design were compared against another IOL design in two studies. We conclude that 0.5 mm. The effect of IOL displacement on visual function is more pronounced in aberration correcting IOLs compared to spherical and standard non-aberration correcting aspherical IOLs and in multifocal versus monofocal IOLs. Internal coma has been frequently associated with IOL tilt and decentration, and this increases with pupil size. There is no correlation between spherical aberration and IOL tilt or decentration. Although IOL tilt produces significant impact on visual outcome in toric IOLs, these lenses are more sensitive to rotation compared to tilt.

1 February 2017 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
CHChristin Henein
Christin Henein
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty

3 October 2014 in Eye
Verified
Journal Article
Open access
PDF file
ZSZ Shalchi
Z Shalchi
XWX Wang
X Wang
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
This review aims to assess the efficacy and safety of epithelial removal (ER) and transepithelial (TE) corneal collagen crosslinking (CXL) for the treatment of keratoconus. We used MEDLINE to identify all ER and TE CXL studies on keratoconic eyes (n≥20, follow-up ≥12 months). Ex vivo and studies for non-keratoconus indications or in conjunction with other procedures were excluded. Data on uncorrected (UDVA) and corrected (CDVA) distance visual acuity, refractive cylinder, maximum keratometry (Kmax), and adverse events were collected at the latest follow-up and 1 year. Only one randomised controlled trial (RCT) qualified inclusion. Forty-four ER and five TE studies were included. For logMAR UDVA, CDVA, mean spherical equivalent, refractive cylinder and Kmax, at latest follow-up 81, 85, 93, 62, and 93% ER studies vs 66.7, 80, 75, 33, and 40% TE studies reported improvement, respectively. Whereas at 1 year, 90, 59, and 91% ER studies vs 80, 50, and 25% TE studies reported improvement, respectively. The majority of studies showed reduced pachymetry in both groups. Treatment failure, retreatment rates, and conversion to transplantation were reported to be up to 33, 8.6, and 6.25%, respectively, in ER studies only. Stromal oedema, haze, keratitis, and scarring were only reported in ER studies, whereas endothelial cell counts remained variable in both groups. Both ER and TE studies showed improvement in visual acuity, refractive cylinder but Kmax worsened in most TE studies. Adverse events were reported more with ER studies. This review calls for more high quality ER and TE studies with comparable parameters for further assessment of safety and efficacy.

1 December 2012 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
DLDamian B. Lake
Damian B. Lake
SDSheraz M. Daya
Sheraz M. Daya
PURPOSE: To evaluate the outcomes of pseudophakic toric intraocular lens (IOL) implantation in eyes with stable keratoconus and cataract. METHODS: Retrospective, noncomparative, case series of 12 eyes from 9 patients (mean age: 63.4±3.5 years) with stable mild to moderate keratoconus and cataract who underwent pseudophakic toric IOL implantation (AT TORBI 709M, AcriTec). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, keratometric findings, adverse events, and postoperative complications were recorded for all eyes. RESULTS: Mean postoperative follow-up was 9.0±8.8 months. At last postoperative follow-up, UDVA was 20/40 or better in 75% and CDVA was 20/40 or better in 83.3% of eyes. Postoperative mean refractive sphere (pre- vs postoperative: −4.80±5.60 vs 0.30±0.50 diopters [D]) and cylinder (pre- vs postoperative: 3.00±1.00 D vs 0.70±0.80 D) were significantly better ( P <.01 for both). No intra- or postoperative complications occurred. No eyes had progression of keratoconus or significant IOL rotation at postoperative follow-up. CONCLUSIONS: Pseudophakic toric IOLs are an effective option and provide good vision in eyes with stable mild to moderate keratoconus and cataract.

1 April 2009 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
DSDavid J. Spalton
David J. Spalton
JBJames Boyce
James Boyce
SSShouvik Saha
Shouvik Saha
JMJohn Marshall
John Marshall
To compare wavefront aberration, depth of focus, contrast sensitivity, and in vivo modulation transfer function (MTF) after fellow-eye implantation of aspheric and spherical intraocular lenses (IOLs). Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom. This prospective randomized controlled study comprised patients with bilateral cataract who received an aspheric AcrySof SN60WF IOL or a spherical AcrySof SN60AT IOL in the first eye and the other IOL in the second eye. Assessments at 3 and 6 months included 100% and 9% logMAR best corrected visual acuity (BCVA) and photopic and mesopic functional acuity contrast testing. Total internal and corneal aberrations and depth of focus were computed. Distance-corrected near logMAR acuity was available at 12 months. At 3 and 6 months, there was no significant difference in 100% and 9% BCVA or photopic contrast sensitivity. Mesopic contrast sensitivity was better and total and internal spherical aberrations were significantly less with the aspheric IOL. Total and internal eye vertical coma was reduced with aspheric IOL. Total MTF was not significantly different between groups. The aspheric IOL group had 0.46 diopter less depth of focus than the spherical IOL group at 6 months (P<.05). Distance-corrected near acuity was significantly better with the spherical IOL. Aspheric IOLs significantly reduced spherical aberration, improving mesopic contrast sensitivity. Vertical coma was reduced with aspheric IOLs. Reduction of aberrations may be responsible for reduced depth of focus with aspheric IOLs. This may be disadvantageous for near vision and reading ability.

1 April 2008 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
DSDavid J. Spalton
David J. Spalton
JBJames Boyce
James Boyce
ABAnthony Brain
Anthony Brain
JMJohn Marshall
John Marshall
To analyze the sharpness of the posterior optic edge profile and edge thickness of intraocular lenses (IOLs) marketed with a square-edged profile. Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom. Seventeen square-edged 20.0 diopter IOLs of different manufacture, design, and material were selected. After the environmental scanning electron microscopy technique was standardized, repeatability of the technique was tested. Posterior optic edges of all IOLs were scanned at a magnification of x 500. Local radii of curvature of the posterior optic edges were measured by purpose-designed software. Optic edge thickness was also measured from the electron micrographs. The repeatability of the scanning technique was excellent (+/-0.10 microm). The radius of curvature of posterior optic edges ranged from 7.6 to 23.1 microm. Hydrophilic acrylic IOLs (except the HumanOptics MC Microlens 611 MI-B and 1CU) had radii of curvatures more than 10.0 microm of the posterior optic edge compared with hydrophobic acrylic and silicone IOLs (<10.0 microm) except the Hoya AF-1 (19.9 microm). Alcon AcrySof single-piece (SN60WF), HumanOptics 1CU, and AMO Clariflex CLRFLXC IOLs had the thinnest optic edges in the hydrophobic, hydrophilic, and silicone groups, respectively. Commercially marketed square-edged IOLs differed in the sharpness of the posterior optic edge. Hydrophobic acrylic and silicone IOLs have sharper posterior optic square edge than most hydrophilic acrylic IOLs. This probably reflects difference in manufacturing techniques. Differences in posterior optic edge profile may explain variation in posterior capsule opacification performance with different IOLs and materials.