The literature on the application of Multispectral and Hyperspectral imaging for identification of pigments on artworks is sparse. While these methods do not provide the analytical capability that spectroscopies do offer, the use of spectral imaging has the advantage of being a rapid and relatively low-cost solution for the examination of large areas. This paper presents a flowchart for the identification of historical pigments applied with gum Arabic using multispectral imaging (wavelength ranging from 360 to 1700 nm) performed with a modified digital camera for infrared, visible and ultraviolet photography; and an InGaAs camera for infrared reflectography. The flowchart method will be most successful on paint made of one layer of pure pigment, and it can selectively discriminate only a fraction of the 56 pigments analyzed. Though, considerably limited in its analytical capabilities, the low cost and speed of the workflow make the method worthwhile, even if only to localize retouching and areas appearing the same hue but painted with different pigments. The InGaAs camera is the only expensive instrument used in this study but its cost is relatively affordable for the average painting conservation studio since only a model with a low pixel count is required (320×256 pixels) rather than a more sophisticated InGaAs scanner system.
Cultural Heritage scientists need methodologies to examine Art and Archaeology in order to understand artistic materials and techniques and devise better conservation procedures. This review discusses the most successful and promising applications of Terahertz (THz) technology in Cultural Heritage Science. THz is used in homeland security and for plenty of other industrial sectors and it presents a number of valuable features specifically for the investigation of Art and Archaeology: No radiation risk, low power, non-contact and reflection mode. Recent technical advancements are also making its application fast, mobile and relatively affordable creating a potential for its diffused implementation in museums. While THz is most promising for the investigation of multilayered art, such as paintings, it has been tested on a very large range of artifacts, from manuscripts to mummies and lacquered historical furniture.
Este artigo discute dois m?todos fotogr?ficos baseados no uso da radia??o ultravioleta para o exame de obras de arte: a fluoresc?ncia de ultravioleta (UVF) e a reflect?ncia de ultravioleta (UVR). Enquanto a fotografia de UVF pode ser efectuada com qualquer m?quina fotogr?fica digital, as imagens de UVR s?o adquiridas com uma m?quina fotogr?fica digital modificada para espectro completo, sens?vel ? radia??o ultravioleta com comprimento de onda at? cerca de 360 nm. Esta modifica??o envolve a remo??o do filtro interno sobre o sensor CCD ou CMOS de forma a tornar a m?quina sens?vel ? radia??o ultravioleta e infravermelha. Este artigo descreve os procedimentos e o equipamento necess?rios para a realiza??o desses exames, discutindo quer estudos de casos quer os resultados obtidos com amostras preparadas com esse objectivo. Este artigo discute dois m?todos fotogr?ficos baseados no uso da radia??o ultravioleta para o exame de obras de arte: a fluoresc?ncia de ultravioleta (UVF) e a reflect?ncia de ultravioleta (UVR). Enquanto a fotografia de UVF pode ser efectuada com qualquer m?quina fotogr?fica digital, as imagens de UVR s?o adquiridas com uma m?quina fotogr?fica digital modificada para espectro completo, sens?vel ? radia??o ultravioleta com comprimento de onda at? cerca de 360 nm. Esta modifica??o envolve a remo??o do filtro interno sobre o sensor CCD ou CMOS de forma a tornar a m?quina sens?vel ? radia??o ultravioleta e infravermelha. Este artigo descreve os procedimentos e o equipamento necess?rios para a realiza??o desses exames, discutindo quer estudos de casos quer os resultados obtidos com amostras preparadas com esse objectivo.
Multispectral imaging systems are used in art examinations to map and identify pigments, binders and areas of retouching. A monochromatic camera is combined with an appropriate wavelength selection system and acquires a variable number of spectral images of a scene. These images are then stacked into a reflectance imaging cube to reconstruct reflectance spectra from each of the images’ pixels. This paper presents an affordable multispectral imaging system composed of a monochromatic CCD camera and a set of only 12 interference filters for mapping pigments on works of art and for the tentative identification of such pigments. This work demonstrates the versatility of this set-up, a versatility enabling it to be applied to different tasks, involving examination and documentation of objects of varying size. Use of this multispectral camera for both panoramic and macro photography is discussed, together with the possibilities facilitated from the coupling of the system to a stereomicroscope and a compound microscope. This system is of particular interest for the cultural heritage sector because of its hardware simplicity and acquisition speed, as well as its lightness and small dimensions