Algimantas Kežionis

Prof. Algimantas Kežionis

research professor
orcid

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Ceramics International
Verified
Journal Article
Closed access
Aleksej ZarkovAleksej Zarkov
Aleksej Zarkov
ASAndrius Stanulis
Andrius Stanulis
TSTomas Salkus
Tomas Salkus
AKAlgimantas Kežionis
Algimantas Kežionis
VJVitalija Jasulaitiene
Vitalija Jasulaitiene
AKAivaras Kareiva
Aivaras Kareiva

1 April 2011 in Solid State Ionics
Verified
Journal Article
Closed access
TŠT. Šalkus
T. Šalkus
EKE. Kazakevičius
E. Kazakevičius
AKAlgimantas Kežionis
Algimantas Kežionis
AOA.F. Orliukas
A.F. Orliukas
JBJ.C. Badot
J.C. Badot
OBO. Bohnke
O. Bohnke

1 April 2011 in Solid State Ionics
Verified
Journal Article
Closed access
AKAlgimantas Kežionis
Algimantas Kežionis
EKEdvardas Kazakevičius
Edvardas Kazakevičius
TŠTomas Šalkus
Tomas Šalkus
AOAntanas Orliukas
Antanas Orliukas

3 September 2014 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
AKAlgimantas Kežionis
Algimantas Kežionis
SKSaulius Kazlauskas
Saulius Kazlauskas
DPDalius Petrulionis
Dalius Petrulionis
AOAntanas Feliksas Orliukas
Antanas Feliksas Orliukas
A model for a measurement circuit consisting of a telescopic coaxial transmission line with the sample placed in the gap of the central conductor has been developed and a measurement method, based on this model, was tested. To determine the sample's electrical properties, the method requires the measurement of the two-port scattering matrices of the short-circuited line, the line with one calibration sample, and the line with the sample to be measured inserted. The model takes into account the thermal elongation of the measurement line and can be used for measuring electrical properties of materials at high temperatures in the megahertz and gigahertz ranges. This model also reduces the influence of parasitic reflections in the measuring coaxial line on the measurement results and takes into account a complicated distribution of the electromagnetic field in the measuring capacitor without solving a complicated electrodynamics problem.

1 January 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
AKAlgimantas Kežionis
Algimantas Kežionis
PBP. Butvilas
P. Butvilas
TŠT. Šalkus
T. Šalkus
SKS. Kazlauskas
S. Kazlauskas
DPD. Petrulionis
D. Petrulionis
AOA. F. Orliukas
A. F. Orliukas
An impedance spectrometer capable of accurately measuring solid ion conducting sample impedance spectra by two- or four-electrode methods in either time or frequency domain has been built. The four-electrode measurement mode is implemented by constructing a differential amplifier with a very high input impedance and common mode rejection ratio over a wide frequency range. All of the measurements can be performed in frequencies ranging from 10 Hz to 2 MHz and sample temperatures up to 800 K. The working principle of the spectrometer as well as its technical parameters and accuracy estimation are presented in this paper. The advantage of four-electrode over two-electrode measurement mode is shown by an example of Ce0.9Gd0.1O1.95 solid electrolyte ceramic impedance measurements.

1 February 2013 in Solid State Ionics
Verified
Journal Article
Closed access
SKSaulius Kazlauskas
Saulius Kazlauskas
AKAlgimantas Kežionis
Algimantas Kežionis
TŠTomas Šalkus
Tomas Šalkus
AOAntanas Feliksas Orliukas
Antanas Feliksas Orliukas