Ines A. Isidro

Dr. Ines A. Isidro

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2023 in Biotechnology and Bioengineering
Verified
Journal Article
Open access
MCMarta H. G. Costa
Marta H. G. Costa
MCMargarida S. Costa
Margarida S. Costa
BPBeatriz Painho
Beatriz Painho
CSCarolina D. Sousa
Carolina D. Sousa
ICInês Carrondo
Inês Carrondo
MSMargarida Serra
Margarida Serra
Extracellular vesicles (EVs) derived from mesenchymal stromal cells (MSCs) act as signaling mediators of cellular responses. However, despite representing a promising alternative to cell‐based therapies, clinical translation of EVs is currently limited by their lack of scalability and standardized bioprocessing. Herein, we integrated scalable downstream processing protocols with standardized expansion of large numbers of viable cells in stirred‐tank bioreactors to improve EV production. Higher EV yields were linked to EV isolation by tangential flow filtration followed by size exclusion chromatography, rendering 5 times higher number of EVs comparatively to density gradient ultracentrifugation protocols. Additionally, when compared to static culture, EV manufacture in bioreactors resulted in 2.2 higher yields. Highlighting the role of operating under optimal cell culture conditions to maximize the number of EVs secreted per cell, MSCs cultured at lower glucose concentration favored EV secretion. While offline measurements of metabolites concentration can be performed, in this work, Raman spectroscopy was also applied to continuously track glucose levels in stirred‐tank bioreactors, contributing to streamline the selection of optimal EV collection timepoints. Importantly, MSC‐derived EVs retained their quality attributes and were able to stimulate angiogenesis in vitro, therefore highlighting their promising therapeutic potential.

17 July 2019 in Biotechnology and Bioengineering
Verified
Journal Article
Closed access
PDF file
DPDaniel Pais
Daniel Pais
RPRui M. C. Portela
Rui M. C. Portela
MCManuel J. T. Carrondo
Manuel J. T. Carrondo
IIInes A. Isidro
Ines A. Isidro
PAPaula M Alves
Paula M Alves

22 April 2020 in Processes
Verified
Journal Article
Open access
PDF file
DPDaniel Pais
Daniel Pais
PGPaulo R. S. Galrão
Paulo R. S. Galrão
AKAnastasiya Kryzhanska
Anastasiya Kryzhanska
JBJérémie Barbau
Jérémie Barbau
IIInes A. Isidro
Ines A. Isidro
PAPaula M Alves
Paula M Alves
The insect cell-baculovirus vector system has become one of the favorite platforms for the expression of viral vectors for vaccination and gene therapy purposes. As it is a lytic system, it is essential to balance maximum recombinant product expression with harvest time, minimizing product exposure to detrimental proteases. With this purpose, new bioprocess monitoring solutions are needed to accurately estimate culture progression. Herein, we used online digital holographic microscopy (DHM) to monitor bioreactor cultures of Sf9 insect cells. Batches of baculovirus-infected Sf9 cells producing recombinant adeno-associated virus (AAV) and non-infected cells were used to evaluate DHM prediction capabilities for viable cell concentration, culture viability and AAV titer. Over 30 cell-related optical attributes were quantified using DHM, followed by a forward stepwise regression to select the most significant (p < 0.05) parameters for each variable. We then applied multiple linear regression to obtain models which were able to predict culture variables with root mean squared errors (RMSE) of 7 × 105 cells/mL, 3% for cell viability and 2 × 103 AAV/cell for 3-fold cross-validation. Overall, this work shows that DHM can be implemented for online monitoring of Sf9 concentration and viability, also permitting to monitor product titer, namely AAV, or culture progression in lytic systems, making it a valuable tool to support the time of harvest decision and for the establishment of controlled feeding strategies.

13 March 2021 in Biotechnology and Bioengineering
Verified
Journal Article
Closed access
PDF file
IIInes A. Isidro
Ines A. Isidro
PVPedro Vicente
Pedro Vicente
DPDaniel Pais
Daniel Pais
JAJoana I. Almeida
Joana I. Almeida
MDMara Domingues
Mara Domingues
MSMargarida Serra
Margarida Serra

29 April 2016 in Bioprocess and Biosystems Engineering
Verified
Journal Article
Closed access
PDF file
IIInes A. Isidro
Ines A. Isidro
RPRui M. Portela
Rui M. Portela
JCJoão J. Clemente
João J. Clemente
ACAntónio E. Cunha
António E. Cunha
Rui Manuel Freitas OliveiraRui Manuel Freitas Oliveira
Rui Manuel Freitas Oliveira

13 November 2020 in Processes
Verified
Journal Article
Open access
PDF file
DPDaniel Pais
Daniel Pais
CBChris Brown
Chris Brown
Anastasia NeumanAnastasia Neuman
Anastasia Neuman
KMKrishanu Mathur
Krishanu Mathur
IIInes A. Isidro
Ines A. Isidro
PSPeter G. Slade
Peter G. Slade
The insect cell-baculovirus expression vector system is an established method for large scale recombinant adeno-associated virus (rAAV) production, largely due to its scalability and high volumetric productivities. During rAAV production it is critical to monitor process parameters such as Spodoptera frugiperda (Sf9) cell concentration, infection timing, and cell harvest viabilities since they can have a significant influence on rAAV productivity and product quality. Herein we developed the use of dielectric spectroscopy as a process analytical technology (PAT) tool used to continuously monitor the production of rAAV in 2 L stirred tank bioreactors, achieving enhanced control over the production process. This study resulted in improved manufacturing robustness through continuous monitoring of cell culture parameters, eliminating sampling needs, increasing the accuracy of infection timing, and reliably estimating the time of harvest. To increase the accuracy of baculovirus infection timing, the cell growth/permittivity model was coupled to a feedback loop with real-time monitoring. This system was able to predict baculovirus infection timing up to 24 h in advance for greatly improved accuracy of infection and ensuring consistent high rAAV productivities. Furthermore, predictive models were developed based on the dielectric measurements of the culture. These multiple linear regression-based models resulted in correlation coefficients (Q2) of 0.89 for viable cell concentration, 0.97 for viability, and 0.92 for cell diameter. Finally, models were developed to predict rAAV titer providing the capability to distinguish in real time between high and low titer production batches.