Toni Varga

Mr. Toni Varga

Faculty of Electrical Engineering, Computer Science and Information Technology, Osijek
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2020 in Electronics
Verified
Journal Article
Open access
PDF file
VŠVedrana Jerković Štil
Vedrana Jerković Štil
TVToni Varga
Toni Varga
TBTin Bensic
Tin Bensic
Marinko BarukčićMarinko Barukčić
Marinko Barukčić
Multi-motor systems are strong coupled multiple-input–multiple-output systems. The main objective in multi-motor drive control is to achieve synchronized operation of all motors in the system. In this paper, multi-motor systems are classified in accordance with their control demands. This paper also provides a systematic categorization of multi-motor synchronization techniques. The review of recent research literature indicates that fuzzy algorithms are widely used in multi-motor control. Finally, in this paper, a review of fuzzy logic controllers and their functionalities in multi-motor control is given.

12 May 2022 in Electronics
Verified
Journal Article
Open access
PDF file
TVToni Varga
Toni Varga
TBTin Bensic
Tin Bensic
Marinko BarukčićMarinko Barukčić
Marinko Barukčić
VŠVedrana Jerković Štil
Vedrana Jerković Štil
An optimization procedure for type 1 Takagi–Sugeno Fuzzy Logic Controller (FLC) parameter tuning is shown in this paper. Ant colony optimization is used to obtain the optimal controller parameters, and only a small amount of post-optimization parameter adjustment is needed. The choice of controller parameters is explained, along with the methodology behind the criterion for objective function value calculation. The optimized controller is implemented as an outer-loop speed controller for Predictive Current Control (PCC) of an induction machine. The performance of the proposed control method is compared with that of several other model predictive control methods. The results show a 55% decrease in speed tracking error and 74% decrease in torque overshoot.

10 July 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Marinko BarukčićMarinko Barukčić
Marinko Barukčić
TVToni Varga
Toni Varga
VŠVedrana Jerković Štil
Vedrana Jerković Štil
TBTin Bensic
Tin Bensic
The paper researches the impact of the input data resolution on the solution of optimal allocation and power management of controllable and non-controllable renewable energy sources distributed generation in the distribution power system. Computational intelligence techniques and co-simulation approach are used, aiming at more realistic system modeling and solving the complex optimization problem. The optimization problem considers the optimal allocation of all distributed generations and the optimal power control of controllable distributed generations. The co-simulation setup employs a tool for power system analysis and a metaheuristic optimizer to solve the optimization problem. Three different resolutions of input data (generation and load profiles) are used: hourly, daily, and monthly averages over one year. An artificial neural network is used to estimate the optimal output of controllable distributed generations and thus significantly decrease the dimensionality of the optimization problem. The proposed procedure is applied on a 13 node test feeder proposed by the Institute of Electrical and Electronics Engineers. The obtained results show a huge impact of the input data resolution on the optimal allocation of distributed generations. Applying the proposed approach, the energy losses are decreased by over 50–70% by the optimal allocation and control of distributed generations depending on the tested network.

5 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TVToni Varga
Toni Varga
TBTin Bensic
Tin Bensic
VŠVedrana Jerković Štil
Vedrana Jerković Štil
Marinko BarukčićMarinko Barukčić
Marinko Barukčić
A speed tracking control method for induction machine is shown in this paper. The method consists of outer speed control loop and inner current control loop. Model predictive current control method without the need for calculation of the weighing factors is utilized for the inner control loop, which generates a continuous set of voltage reference values that can be modulated and applied by the inverter to the induction machine. Interesting parallels are drawn between the developed method and state feedback principles that helped with the analysis of the stability and controllability. Simple speed and rotor flux estimator is implemented that helps achieve sensorless control. Simulation is conducted and the method shows great performance for speed tracking in a steady state, and during transients as well. Additionally, compared to the finite control set predictive current control, it shows less harmonic content in the generated torque on the rotor shaft.

20 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
Marinko BarukčićMarinko Barukčić
Marinko Barukčić
TVToni Varga
Toni Varga
TBTin Bensic
Tin Bensic
VŠVedrana Jerković Štil
Vedrana Jerković Štil
The main problem in planning the optimal operation of renewable energy sources and battery storage systems is the amount of data that must be considered to cover an entire observation period. If the observation period is one year, the characteristic days or averaged data (daily, weekly or monthly averages) are considered to reduce the number of data. Since the average values of the entered data differ from the actual values, it is better to work with hourly or 15-min data at the annual level. The study presents a framework for solving the problem of the optimal allocation and operation of renewable energy sources and battery storage systems. The proposed method simultaneously solves the optimal allocation and energy management problem considering hourly data at the annual level. The fuzzy inference-based system is proposed for scheduling optimal profiles of battery storage systems and renewable energy sources. The developed fuzzy inference system manages the power factors of the photovoltaic and wind power systems, the power factor and output of the biogas plant, and the operating status of the battery storage system. The presented method simultaneously finds the optimal parameters of the energy management system and the optimal allocation and operation of the renewable energy sources and the battery storage system. The developed method is based on the calculation of steady-state power flow. The proposed method is to be used in the design phase for the installation of various renewable energy sources and battery storage systems. In addition, the method is intended to be used to optimally control the power output of energy sources and the operation of energy storage systems during steady-state operation in order to operate the distribution network with minimum annual active energy losses. The developed method is applied to the test distribution system IEEE with 37 nodes. The reduction in annual energy losses in the tested distribution system is about 80% compared to the base case without renewable energy sources and battery storage system.

6 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TBTin Bensic
Tin Bensic
TVToni Varga
Toni Varga
Marinko BarukčićMarinko Barukčić
Marinko Barukčić
VŠVedrana Jerković Štil
Vedrana Jerković Štil
This paper presents a method for selecting the sampling time for induction machine parameter estimation from the machine line start measurements. the metaheuristic optimization method is used to find the optimal Prony exponential series approxiamtion of the line start transient current. From the optimal approximation, poles of the linearized induction machine model are computed and used to determine the optimal sampling time. the results show that sampling frequencies needed for parameter estimation are much lower than 1–15 kHz commonly used today. This reduces the necessary amount of collected data and the computing power needed for the estimation. the optimal sampling time is computed for the simulated and for the measured data. Referenced parameter estimation technique is tested for the measured transient showing benefits of using the optimal sampling time.