Guiqin Yan

Dr. Guiqin Yan

Shanxi Normal University

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
YMYanming Miao
Yanming Miao
ZZZhifeng Zhang
Zhifeng Zhang
YGYan Gong
Yan Gong
GYGuiqin Yan
Guiqin Yan

1 November 2015 in Analytical Biochemistry
Verified
Journal Article
Closed access
ZZZhifeng Zhang
Zhifeng Zhang
YMYanming Miao
Yanming Miao
LLLinwang Lian
Linwang Lian
GYGuiqin Yan
Guiqin Yan

1 June 2015 in Analytical Biochemistry
Verified
Journal Article
Closed access
ZZZhifeng Zhang
Zhifeng Zhang
YMYanming Miao
Yanming Miao
QZQindi Zhang
Qindi Zhang
GYGuiqin Yan
Guiqin Yan

19 March 2019 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
SLShiqing Luo
Shiqing Luo
YMYanming Miao
Yanming Miao
JGJunping Guo
Junping Guo
XSXiaojie Sun
Xiaojie Sun
GYGuiqin Yan
Guiqin Yan

1 December 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
ZZZhifeng Zhang
Zhifeng Zhang
JYJiajia Yang
Jiajia Yang
WPWenting Pang
Wenting Pang
GYGuiqin Yan
Guiqin Yan
Bacterial toxin contamination is a serious food safety issue. Rapid, facile detection of bacterial toxins in food is crucial to control their harmful effects on human health. In this study, a facile, selective, and cost-effective method with a 6-carboxy-X-rhodamine labeled lipopolysaccharide binding aptamer (ROX-LBA)/GO fluorescent probe was developed based on the specific recognition characteristics of aptamers and the super fluorescence quenching efficiency of graphene oxide (GO) and used for the detection of lipopolysaccharides (LPS). ROX-LBA is adsorbed on the GO surface because of its strong π–π stacking interactions in the flexible single-stranded state, and fluorescence is quenched by GO via Förster resonance energy transfer (FRET). After adding LPS, the aptamer binds to LPS and forms a LPS/ROX-LBA complex, which exhibits weak binding affinity with GO. ROX-LBA cannot effectively combine with GO, and fluorescence is restored. The concentration of LPS can be quantitatively analyzed by observing fluorescence changes in the sensing system. The fluorescence intensity proportionally increases with LPS concentration (25–1600 ng mL−1), and the detection limit is 15.7 ng mL−1. Hence, the proposed method provides an alternative strategy for the specific detection of endotoxin in drink samples (e.g., apple juice and beer) and could be widely applied to quantify various bacterial toxins by replacing the aptamer sequences.