Tanvir Khan

Dr. Tanvir Khan

FSEC Energy Research Center, a research Institute of the University of Central Florida, Cocoa, FL 32922, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2017 in Geoscientific Model Development
Verified
Journal Article
Open access
PDF file
TKTanvir Khan
Tanvir Khan
JPJudith Perlinger
Judith Perlinger
Despite considerable effort to develop mechanistic dry particle deposition parameterizations for atmospheric transport models, current knowledge has been inadequate to propose quantitative measures of the relative performance of available parameterizations. In this study, we evaluated the performance of five dry particle deposition parameterizations developed by Zhang et al. (2001) (Z01), Petroff and Zhang (2010) (PZ10), Kouznetsov and Sofiev (2012) (KS12), Zhang and He (2014) (ZH14), and Zhang and Shao (2014) (ZS14), respectively. The evaluation was performed in three dimensions: model ability to reproduce observed deposition velocities, Vd (accuracy); the influence of imprecision in input parameter values on the modeled Vd (uncertainty); and identification of the most influential parameter(s) (sensitivity). The accuracy of the modeled Vd was evaluated using observations obtained from five land use categories (LUCs): grass, coniferous and deciduous forests, natural water, and ice/snow. To ascertain the uncertainty in modeled Vd, and quantify the influence of imprecision in key model input parameters, a Monte Carlo uncertainty analysis was performed. The Sobol' sensitivity analysis was conducted with the objective to determine the parameter ranking from the most to the least influential. Comparing the normalized mean bias factors (indicators of accuracy), we find that the ZH14 parameterization is the most accurate for all LUCs except for coniferous forest, for which it is second most accurate. From Monte Carlo simulations, the estimated mean normalized uncertainties in the modeled Vd obtained for seven particle sizes (ranging from 0.005 to 2.5 µm) for the five LUCs are 17, 12, 13, 16, and 27 % for the Z01, PZ10, KS12, ZH14, and ZS14 parameterizations, respectively. From the Sobol' sensitivity results, we suggest that the parameter rankings vary by particle size and LUC for a given parameterization. Overall, for dp = 0.001 to 1.0 µm, friction velocity was one of the three most influential parameters in all parameterizations. For giant particles (dp = 10 µm), relative humidity was the most influential parameter. Because it is the least complex of the five parameterizations, and it has the greatest accuracy and least uncertainty, we propose that the ZH14 parameterization is currently superior for incorporation into atmospheric transport models.

29 March 2018 in Environmental Science: Processes & Impacts
Verified
Journal Article
Open access
PDF file
WKW. Charles Kerfoot
W. Charles Kerfoot
NUNoel R. Urban
Noel R. Urban
CMCory P. McDonald
Cory P. McDonald
HZHuanxin Zhang
Huanxin Zhang
RRRonald Rossmann
Ronald Rossmann
MBMorgan Bolstad
Morgan Bolstad
A geographic enigma is that present-day atmospheric deposition of mercury in the Upper Peninsula of Michigan is low (48%) and that regional industrial emissions have declined substantially (ca. 81% reduction) relative to downstate. Mercury levels should be declining. However, state (MDEQ) surveys of rivers and lakes revealed elevated total mercury (THg) in Upper Peninsula waters and sediment relative to downstate. Moreover, Western Upper Peninsula (WUP) fish possess higher methyl mercury (MeHg) levels than Northern Lower Peninsula (NLP) fish. A contributing explanation for elevated THg loading is that a century ago the Upper Peninsula was a major industrial region, centered on mining. Many regional ores (silver, copper, zinc, massive sulfides) contain mercury in part per million concentrations. Copper smelters and iron furnace-taconite operations broadcast mercury almost continuously for 140 years, whereas mills discharged tailings and old mine shafts leaked contaminated water. We show that mercury emissions from copper and iron operations were substantial (60–650 kg per year) and dispersed over relatively large areas. Moreover, lake sediments in the vicinity of mining operations have higher THg concentrations. Sediment profiles from the Keweenaw Waterway show that THg accumulation increased 50- to 400-fold above modern-day atmospheric deposition levels during active mining and smelting operations, with lingering MeHg effects. High MeHg concentrations are geographically correlated with low pH and dissolved organic carbon (DOC), a consequence of biogeochemical cycling in wetlands, characteristic of the Upper Peninsula. DOC can mobilize metals and elevate MeHg concentrations. We argue that mercury loading from mining is historically superimposed upon strong regional wetland effects, producing a combined elevation of both THg and MeHg in the Western Upper Peninsula.

16 September 2019 in Environmental Science: Processes & Impacts
Verified
Journal Article
Open access
PDF file
TKTanvir Khan
Tanvir Khan
DOD. Obrist
D. Obrist
YAY. Agnan
Y. Agnan
NSN. E. Selin
N. E. Selin
JPJudith Perlinger
Judith Perlinger
The resistance-based models combined with a new soil re-emission parameterization reproduce the observed diel and seasonal patterns of Hg0exchange.

17 January 2022 in Indoor and Built Environment
Verified
Journal Article
Closed access
PDF file
TKTanvir Khan
Tanvir Khan
CWCharles Withers
Charles Withers
EMEric Martin
Eric Martin
NBNicolas Bonilla
Nicolas Bonilla
Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

15 August 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
TKTanvir Khan
Tanvir Khan
ZEZachery I. Emerson
Zachery I. Emerson
KMKaren Mentz
Karen Mentz
The comparison between Federal Equivalent Method (FEM) and Federal Reference Method (FRM) monitors in measuring fine particulate matter (PM2.5) concentrations frequently raises concerns about the accuracy and reliability of data. The comparability, or lack thereof, of data between FRM and FEM monitors may have significant implications for maintaining compliance with the National Ambient Air Quality Standards (NAAQSs). This study investigates the performance of continuous FEM monitors collocated with FRM monitors across 10 EPA regions in the U.S., focusing on PM2.5 measurements collected from 276 monitoring stations. Through an analysis of annually averaged paired concentration data, the study examines concentration ratios (FEM/FRM) and associated biases (in %, defined as [(FEM/FRM)−1] × 100) in FEM monitors across different manufacturers, measurement methods, EPA regions, and sampling location types. The study findings reveal a varied distribution of FEM/FRM ratios, with more than 50% of the FEM monitors having FEM/FRM > 1.1 and approximately 30% having FEM/FRM > 1.2. Substantial variations in estimated biases are identified among monitor types, measurement methods, EPA regions, and sampling site locations. Light scatter-based FEM monitors, notably Teledyne models 640 and 640x, dominate all locations (urban, suburban, and rural), with rural areas exhibiting higher mean bias values for both light scatter and beta attenuation FEM monitors (41% and 23%, respectively). On average, light scatter-based FEM monitors demonstrate higher biases compared to beta attenuation monitors across all EPA regions (28% vs. 12%). Irrespective of the measurement method employed, FEM monitors demonstrate a significant positive bias (mean bias 22%) relative to FRM monitors, which could result in an overestimation of PM2.5 design values (DVs) by 13–21% at monitoring sites designating FEMs as primary monitors for NAAQSs compliance designations. These findings emphasize the critical need to address method comparability issues, especially considering the recent tightening of NAAQSs for PM2.5 (annual) from 12 µg/m3 to 9 µg/m3 in the U.S.

TKTanvir Khan
Tanvir Khan
DPDanny S. Parker
Danny S. Parker
CWCharles Withers
Charles Withers
Historically, reducing aerosol-based transmission of respired viruses in indoor environments has been of importance for controlling influenza viruses and common-cold rhinoviruses. The present public health emergency associated with SARS-CoV-2 makes this topic critically important. Yet to be tested is the potential effectiveness of simple interventions that create an isolation zone (IZ) for a suspected/confirmed sick or sensitive person requiring quarantine. The intent in existing homes is to find a practical means to mitigate exposure to airborne contaminants. In creating an IZ in an occupied single-family home in the study, four simple strategies were tested. The test configurations were: (1) IZ windows closed with IZ bathroom exhaust ventilation fan off, (2) IZ windows closed with IZ exhaust fan on, (3) IZ window open with IZ exhaust fan off, and (4) IZ window open with IZ exhaust fan on. Incense-generated fine particulate matter (PM2.5) was used as a marker for virus transmission. The measured transfer of PM2.5 from the IZ into the main zone (MZ) of the house enabled us to determine the relative effectiveness of four containment strategies. Collectively, the data from pressure differential (across zones) and PM2.5 measurements suggested that the best containment strategy was achieved through continuously operating the bathroom exhaust fan while keeping the windows closed in the IZ (configuration 2). Interventions using open windows were found to be less reliable, due to variability in wind speed and direction, resulting in an unpredictable and sometimes detrimental pressure differential in the IZ with reference to MZ. Our findings strongly suggest a simple IZ exhaust ventilation strategy has the potential for mitigating the risk from the airborne spread of contaminants, such as SARS-CoV-2.