Kenji Sueyoshi

Dr. Kenji Sueyoshi


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2019 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
DKDaiki Kawasaki
Daiki Kawasaki
HYHirotaka Yamada
Hirotaka Yamada
KMKenichi Maeno
Kenichi Maeno
KSKenji Sueyoshi
Kenji Sueyoshi
HHHideaki Hisamoto
Hideaki Hisamoto
TETatsuro Endo
Tatsuro Endo

28 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
DKDaiki Kawasaki
Daiki Kawasaki
HYHirotaka Yamada
Hirotaka Yamada
KSKenji Sueyoshi
Kenji Sueyoshi
HHHideaki Hisamoto
Hideaki Hisamoto
TETatsuro Endo
Tatsuro Endo
The coronavirus disease (COVID-19) caused by SARS-CoV-2 has caused a global pandemic. To manage and control the spread of the infection, it is crucial to develop and implement technologies for the early identification of infected individuals and rapid informatization in communities. For the realization of such a technology, a widely available and highly usable sensor for sensitive and specific assay of the virus plays a fundamental role. In this study, we developed an optical sensor based on an imprinted photonic crystal film (IPCF) for quick, simple, and cost-effective detection of SARS-CoV-2 spike protein in artificial saliva. Our IPCF sensor enabled label-free and highly sensitive detection with a smartphone-equipped optical setup. The IPCF surface was functionalized with an anti-SARS-CoV-2 spike protein antibody for immunoassay. We evaluated the specificity and sensitivity of the IPCF sensor for quantitative detection of the spike protein in artificial saliva using simple reflectometry with a spectrometer-equipped optical setup. Specific and quantitative detection of the spike protein was successfully achieved, with a low detection limit of 429 fg/mL. In the demonstration of reflectometric detection with a smartphone-equipped setup, the sensitivity was comparable with that with a spectrometer-equipped setup. The test result is returned immediately and can be saved to cloud storage. In addition, it costs less than USD 1 for one IPCF to be used for diagnosis. Thus, the developed IPCF has the potential to realize a widely available and highly usable sensor.

5 January 2015 in The Analyst
Verified
Journal Article
Closed access
PDF file
SFShun-Ichi Funano
Shun-Ichi Funano
MSMasato Sugahara
Masato Sugahara
THTerence G. Henares
Terence G. Henares
KSKenji Sueyoshi
Kenji Sueyoshi
TETatsuro Endo
Tatsuro Endo
HHHideaki Hisamoto
Hideaki Hisamoto
A single-step, easy-to-use enzyme immunoassay capillary sensor, composed of functional multilayer coatings, was developed in this study. The coatings were composed of substrate-immobilized hydrophobic coating, hydrogel coating, and soluble coating containing an enzyme-labeled antibody. The response mechanism involved a spontaneous immunoreaction triggered by capillary action-mediated introduction of a sample antigen solution and subsequent separation of unreacted enzyme-labeled antibodies and antigen-enzyme-labeled antibody complexes by the molecular sieving effect of the hydrogel. An enzyme reaction at the substrate-immobilized hydrophobic coating/hydrogel coating interface resulted in a protein-selective fluorescence response. An antigen concentration-dependent response was obtained for diagnostic marker protein samples (hemoglobin A1c (HbA1c), 7.14–16.7 mg mL−1; alpha-fetoprotein (AFP), 1.4–140 ng mL−1; C-reactive protein (CRP), 0.5–10 μg mL−1) that cover a clinically important concentration range. The successful measurement of CRP in diluted serum samples demonstrated the application of this capillary sensor.


28 April 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
SFSatoko Fujiwara
Satoko Fujiwara
KMKyojiro Morikawa
Kyojiro Morikawa
TETatsuro Endo
Tatsuro Endo
HHHideaki Hisamoto
Hideaki Hisamoto
KSKenji Sueyoshi
Kenji Sueyoshi
Exosomes, a type of extracellular vesicle with a diameter of 30–150 nm, perform key biological functions such as intercellular communication. Recently, size sorting of exosomes has received increasing attention in order to clarify the correlation between their size and components. However, such sorting remains extremely difficult. Here, we propose to sort their size by controlling their electrokinetic migration in nanochannels in a micro-nanofluidic device, which is achieved by tuning the thickness of the electric double layers in the nanochannels. This approach was demonstrated experimentally for exosomes smaller than 250 nm. Using different running buffer concentrations (1 × 10−3, 1 × 10−4, and 1 × 10−5 M), most of the exosomes larger than 140, 110, and 80 nm were successfully cut off at the downstream of the nanochannels, respectively. Therefore, it is clarified that the proposed method is applicable for the size sorting of exosomes.

18 April 2016 in The Analyst
Verified
Journal Article
Closed access
PDF file
ASAkihiro Shirai
Akihiro Shirai
THTerence G. Henares
Terence G. Henares
KSKenji Sueyoshi
Kenji Sueyoshi
TETatsuro Endo
Tatsuro Endo
HHHideaki Hisamoto
Hideaki Hisamoto
A single-step, easy-to-use, and fast capillary-type immunoassay device composed of a polyethylene glycol (PEG) coating containing two kinds of antibody-reagents, including an antibody–graphene oxide conjugate and fluorescently labelled antibody, was developed in this study. The working principle involved the spontaneous dissolution of the PEG coating, diffusion of reagents, and subsequent immunoreaction, triggered by the capillary action-mediated introduction of a sample solution. In a sample solution containing the target antigen, two types of antibody reagents form a sandwich-type antigen–antibody complex and fluorescence quenching takes place via fluorescence resonance energy transfer between the labelled fluorescent molecules and graphene oxide. Antigen concentration can be measured based on the decrease in fluorescence intensity. An antigen concentration-dependent response was obtained for the model target protein sample (human IgG, 0.2–10 μg mL−1). The present method can shorten the reaction time to within 1 min (approximately 40 s), while conventional methods using the same reagents require reaction times of approximately 20 min because of the large reaction scale. The proposed method is one of the fastest immunoassays ever reported. Finally, the present device was used to measure human IgG in diluted serum samples to demonstrate that this method can be used for fast medical diagnosis.