Andrew Breksa

Dr. Andrew Breksa


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2012 in Food Chemistry
Verified
Journal Article
Closed access
WQWenjuan Qu
Wenjuan Qu
ABAndrew Breksa
Andrew Breksa
ZPZhongli Pan
Zhongli Pan
HMHaile Ma
Haile Ma

29 March 2011 in Journal of the Science of Food and Agriculture
Verified
Journal Article
Closed access
PDF file
ABAndrew Breksa
Andrew Breksa
TKTracy Kahn
Tracy Kahn
AZAudrius A Zukas
Audrius A Zukas
MHMarlene B Hidalgo
Marlene B Hidalgo
MYMichelle Lee Yuen
Michelle Lee Yuen

31 March 2020 in Journal of Food Quality
Verified
Journal Article
Open access
PDF file
RMRebecca Milczarek
Rebecca Milczarek
AVAna Vilches
Ana Vilches
COCarl W. Olsen
Carl W. Olsen
ABAndrew Breksa
Andrew Breksa
BMBruce E. Mackey
Bruce E. Mackey
MBMaria Theresa Brandl
Maria Theresa Brandl
Recent efforts have been made to develop hot-air-dried chips as a value-added product for persimmon fruit (Diospyros kaki). However, the long-term quality of this product and its dependence on processing conditions and packaging type have not yet been explored. Hence, in this work, chips were prepared from “Hachiya” persimmon fruit in 2 ways: 2 mm thickness fruit slices, hot-air-dried for 5 hours (Preparation 2–5), and 6 mm slices, dried for 10 hours (Preparation 6–10). The dried chips were then packaged into 2 bag types (plastic zip-top and metallized polyethylene terephthalate (Met-PET) with desiccant packets), stored under ambient conditions, and sampled for moisture-related, microbial, texture, and chemical quality traits throughout the 1-year storage study. It was found that–with the exception of a marked decrease in ascorbic acid (vitamin C)—all 4 Preparation/Packaging combinations yielded products that maintained acceptable color, microbial, nutritional, and textural quality throughout the entire study. Compared to Preparation 2–5 chips, Preparation 6–10 chips generally had lower contents of healthy nutrients—antioxidant compounds, ascorbic acid, and carotenoids. Evidence of invertase activity was found for Preparation 6–10 chips but not for Preparation 2–5 chips. For both preparations, the contents of ascorbic acid and carotenoids experienced time-dependent decreases. Plastic zip-top bags and Met-PET bags with desiccant packets performed equally well as packaging for most of the quality metrics tracked during this study. Overall, this work has demonstrated that hot-air-drying of persimmon slices is a promising approach to create a value-added product with at least one year of shelf-life.

12 May 2015 in Beverages
Verified
Journal Article
Open access
PDF file
ABAndrew Breksa
Andrew Breksa
DKDarwin King
Darwin King
AVAna Vilches
Ana Vilches
A method for the identification and quantification of citrus limonoid glucosides in juices, based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlich’s reagent, has been developed. This method utilizes a phenyl stationary phase and an isocratic mobile phase. Limit of detection for the method was determined to be 50 ng of limonin glucoside. Limonin glucoside and the other limonoid glucosides tested responded equivalently to the post-column reaction with Ehrlich’s reagent suggesting that limonin glucoside may be used as a surrogate for the quantification of other limonoid glucosides, including nomilin, deacetyl nomilin, nomilinic acid, deacetyl nomilinic acid, and obacunone glucosides. For most juice samples, no sample treatment is required to determine limonin glucoside content. Concentration by solid phase extraction is recommended for juices with low levels of limonin glucoside and to facilitate the detection and quantification of other limonoid glucosides present at low concentrations. With the exception of blood oranges, the method was successfully applied to the analysis of juices from a variety of citrus varieties.

30 March 2026 in Agriengineering
Verified
Journal Article
Open access
PDF file
Jaya Shankar TumuluruJaya Shankar Tumuluru
Jaya Shankar Tumuluru
PFPaul Funk
Paul Funk
RHRon Haff
Ron Haff
ABAndrew Breksa
Andrew Breksa
JMJoseph Sherwood McIntyre
Joseph Sherwood McIntyre
WYwallace yokoyama
wallace yokoyama
Research is needed to improve walnut drying throughput and energy consumption in hulling plants, but current methods for sampling nuts in commercial drying bins and measuring nut moisture content limit the capacity to investigate the drying process thoroughly. A novel apparatus for obtaining walnut samples at multiple depths and locations in stadium drying bins and a novel rapid method for accurately determining walnut in-shell moisture content were developed. A second rapid moisture measurement method involving near-infrared light (NIR) was also investigated. The sampling apparatus consisted of three sampling columns installed in each walnut drying bin. Each column had gate valves at four elevations, admitting approximately 30 in-shell walnuts to rectangular buckets hanging on a cable just below each gate valve. To collect samples, the gates were opened and closed, the buckets were withdrawn, the nut samples were collected and sealed in labeled bags, and then the buckets were returned to the column to be ready for the next sampling interval. This configuration, sampling nuts at four levels across three locations in the drying bin, allowed better moisture content variability investigation during in-bin walnut drying. The rapid moisture content measurement method consisted of selecting twelve representative in-shell walnuts from each sample and grinding them in a mill. Twelve grams were sub-sampled from the well-mixed ground material and dried in an oven at 105 ± 1 °C for 3 h, then reweighed to determine moisture loss. The coefficient of variation for sub-samples within an individual sample (n = 4) averaged 2.65% for moisture contents ranging from 6% to 47% dry basis. The rapid moisture content measurement method reduced the drying time from 24 h to 3 h compared to conventional oven drying method, with an accuracy of ±0.5 to 1.5% of the full moisture content range. The best correlation observed between the NIR methodology and the rapid moisture content method was 0.74 R2. These new in-bin walnut sampling and moisture-content measurement methods will accelerate future research aimed at improving walnut drying at commercial huller facilities.