Aidong Zeng

Dr. Aidong Zeng

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2015 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
PDF file
AZAidong Zeng
Aidong Zeng
Qingshan XuQingshan Xu
Qingshan Xu
MDMaosheng Ding
Maosheng Ding
KYKazuto Yukita
Kazuto Yukita
KIKatsuhiro Ichiyanagi
Katsuhiro Ichiyanagi

19 March 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
JNJia Ning
Jia Ning
Sipeng HaoSipeng Hao
Sipeng Hao
AZAidong Zeng
Aidong Zeng
BCBin Chen
Bin Chen
YTYi Tang
Yi Tang
The high penetration of renewable energy brings great challenges to power system operation and scheduling. In this paper, a multi-timescale coordinated method for source-grid-load is proposed. First, the multi-timescale characteristics of wind forecasting power and demand response (DR) resources are described, and the coordinated framework of source-grid-load is presented under multi-timescale. Next, economic scheduling models of source-grid-load based on multi-timescale DR under network constraints are established in the process of day-ahead scheduling, intraday scheduling, and real-time scheduling. The loads are classified into three types in terms of different timescale. The security constraints of grid side and time-varying DR potential are considered. Three-stage stochastic programming is employed to schedule resources of source side and load side in day-ahead, intraday, and real-time markets. The simulations are performed in a modified Institute of Electrical and Electronics Engineers (IEEE) 24-node system, which shows a notable reduction in total cost of source-grid-load scheduling and an increase in wind accommodation, and their results are proposed and discussed against under merely two timescales, which demonstrates the superiority of the proposed multi-timescale models in terms of cost and demand response quantity reduction.

27 September 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
JWJiawei Wang
Jiawei Wang
AZAidong Zeng
Aidong Zeng
YWYaheng Wan
Yaheng Wan
In the integrated energy system, significant potential exists for the regulation of the heat storage capacity within the heating network. In relation to this attribute, the establishment of the quasi-dynamic model for the heating network is accomplished through the utilization of the fictitious node method. Additionally, a method is introduced to quantify the heat storage within the heating network. Moreover, a multi-time-scale scheduling approach is proposed for the integrated energy system, with consideration given to the heat storage of the heating network. During the day-ahead scheduling phase, the active regulation of the heat storage within the heating network is carried out to enhance the economy of system operation. Transitioning to the intra-day upper scheduling phase, the heat storage capacity of the heating network is utilized to eliminate the transmission delay effect, thereby achieving the coordinated scheduling of both electricity and heat. Shifting to the intra-day lower scheduling phase, the heat storage capacity of the heating network is utilized to enhance the operational flexibility of the power system. Simulation experiments demonstrate that the coordinated scheduling of electricity and heat in the integrated energy system can be effectively achieved through the utilization of the fictitious node method. Furthermore, the proposed multi-time-scale scheduling method, making full use of the heat storage characteristics of the heating network, can effectively suppress fluctuations in the new energy output and load demand while taking the economy into account. In this paper, it results in a 5.9% improvement in system operating economics and possesses the capacity to mitigate wind power fluctuations with an error rate of approximately 20%. This capability significantly enhances the integration of wind power as a sustainable energy source.

1 November 2016 in Energy Procedia
Verified
Journal Article
Open access
AZAidong Zeng
Aidong Zeng
XQXu Qingshan
Xu Qingshan
WKWang Kai
Wang Kai
JLJiang Ling
Jiang Ling
WXWang Xudong
Wang Xudong
The energy supply center of the multi energy interconnected region is an energy station, which contains many types of energy supply equipment to match the cold, heating and power loads. This paper proposed a day-ahead optimal economic dispatch model for multi energy interconnected region based on centralized and interconnected energy exchange framework. In the model, the constraints of regional network topology are taken into account. The model is solved by the interior point method in this paper. A case study shows that by performing the schedule made by the dispatch model, the daily operation cost of the multi energy interconnected region decreasing remarkably, thus demonstrates the effectiveness of the proposed economic dispatch schedule

1 January 2025 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
AZAidong Zeng
Aidong Zeng
ZWZirui Wang
Zirui Wang
JWJiawei Wang
Jiawei Wang
SHSipeng Hao
Sipeng Hao
MWMingshen Wang
Mingshen Wang
To leverage the complementary advantages of hydrogen, electricity, and heat, this paper proposes a coordinated optimization scheduling method for an integrated electricity–hydrogen–heat energy system, considering the dynamic operating temperature of proton exchange membrane electrolyzers and the thermal storage capacity of pipeline networks. First, a refined PEM operational model is established by analyzing its hydrogen production efficiency and temperature characteristics under fluctuating power scenarios. On this basis, a comprehensive hydrogen lifecycle model is established, encompassing production, storage, and utilization. On the thermal supply side, a quantitative pipeline network thermal storage model is constructed using a fictitious node method to further explore the system’s flexibility potential. Finally, to achieve optimal economic performance and maximize the utilization of wind and solar energy, an integrated optimization scheduling model is formulated, considering the operational constraints of all devices. Case study results demonstrate that PEM electrolyzers can convert excess electricity into stored heat at the cost of reduced hydrogen production efficiency, effectively facilitating energy flow coordination. Moreover, the thermal storage capability of the pipeline network enhances the system’s overall heat regulation capacity, maintaining PEM hydrogen production efficiency and promoting the local consumption of renewable energy.

5 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
AZAidong Zeng
Aidong Zeng
Sipeng HaoSipeng Hao
Sipeng Hao
JNJia Ning
Jia Ning
Qingshan XuQingshan Xu
Qingshan Xu
LJLing Jiang
Ling Jiang
A real-time error correction operation model for an integrated energy system is proposed in this paper, based on the analysis of the real-time optimized operation structure of an integrated energy system and the characteristics of the system. The model makes real-time corrections to the day-ahead operation strategy of the integrated energy system, to offset forecast errors from the renewable power generation system and multi-energy load system. When unbalanced power occurs in the system due to prediction errors, the model comprehensively considers the total capacity of each energy supply and energy storage equipment, adjustable margin, power climbing speed and adjustment cost, to formulate the droop rate which determines the unbalanced power that each device will undertake at the next time interval, while taking the day-ahead dispatching goals of the system into consideration. The case study shows that the dispatching strategy obtained by the real-time error correction operation model makes the power output change trend of the energy supply equipment consistent with the day-ahead dispatching plan at the next time interval, which ensures the safety, stability and economy of the real-time operation of the integrated energy system.