Erhan Zor

Prof. Erhan Zor

Necmettin Erbakan University,Faculty of Education & GNM Research Group, 42090, Konya,Turkey

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FCFunda Copur
Funda Copur
NBNisa Bekar
Nisa Bekar
Erhan ZorErhan Zor
Erhan Zor
SASabri Alpaydin
Sabri Alpaydin
HBHaluk Bingol
Haluk Bingol

1 April 2013 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Erhan ZorErhan Zor
Erhan Zor
IPImren Hatay Patir
Imren Hatay Patir
HBHaluk Bingol
Haluk Bingol
MEMustafa Ersoz
Mustafa Ersoz

21 October 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
Erhan ZorErhan Zor
Erhan Zor
HBHaluk Bingol
Haluk Bingol
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius
MEMustafa Ersoz
Mustafa Ersoz
Here, we report a novel enantioselective electrochemical biosensor for the discrimination of cystine enantiomers (D- and L-cystine) using a chiral interface for the specific recognition of D- and L-cystine. The biosensor is based on reduced graphene oxide modified by β-cyclodextrin (rGO/β-CD) at the GCE surface. During the preparation of rGO/β-CD/GCE, the modified electrode surfaces were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The electrochemical behaviours of the D- and L-cystine were investigated using the rGO/β-CD/GCE by CV and compared to bare GCE. A clear separation between the oxidation peak potentials of D- and L-cystine was observed at 1.32 and 1.42 V, respectively. The electrochemical discrimination performance of the fabricated chiral sensor was also examined by differential pulse voltammetry (DPV) in a mixed solution of D- and L-cystine. In addition, the DPV technique was used for the determination of D- and L-cystine at low concentration values in the range of 1.0–10.0 μM. To investigate the amperometric response of rGO/β-CD/GCE towards D- and L-cystine, the chronoamperometry technique was used in the concentration range of 10.0–100.0 μM. The interactions of the enantiomers with rGO/β-CD were modelled by molecular docking using AutoDock Vina, and the interaction energies were predicted to be −4.8 and −5.3 kcal mol−1 for D- and L-cystine, respectively. The corresponding values of binding constants were calculated to be 3.32 × 103 and 7.71 × 103 M−1, respectively. The experimental and molecular docking results indicate that the rGO/β-CD/GCE has a different affinity for each enantiomer.

19 December 2022 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
EGEda Gumus
Eda Gumus
HBHaluk Bingol
Haluk Bingol
Erhan ZorErhan Zor
Erhan Zor

1 June 2017 in Analytica Chimica Acta
Verified
Journal Article
Closed access
SASalih Ates
Salih Ates
Erhan ZorErhan Zor
Erhan Zor
IAIlker Akin
Ilker Akin
HBHaluk Bingol
Haluk Bingol
SASabri Alpaydin
Sabri Alpaydin
EAEmine G. Akgemci
Emine G. Akgemci

11 June 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
Erhan ZorErhan Zor
Erhan Zor
MSMuhammed Esad Saglam
Muhammed Esad Saglam
SASabri Alpaydin
Sabri Alpaydin
HBHaluk Bingol
Haluk Bingol
We report on fluorometric and voltammetric detection of L-methionine (Met) based on host–guest interactions between Met and reduced graphene oxide/α-cyclodextrin (rGO/α-CD) hybrid materials. For voltammetric measurements, rGO/α-CD was used as an electrode modification material and successful detection of Met was achieved. Also, rGO/α-CD was used as a fluorescence quencher (turn off) for luminol which was employed as a fluorescent probe. The addition of Met into the same solution gave rise to fluorescence enhancement (turn on) after the host–guest recognition between Met and rGO/α-CD which caused the release of luminol. Interactions of luminol and Met with rGO/α-CD were modeled by molecular docking using AutoDock Vina and the interaction energies were predicted to be −4.3 and −4.4 kcal mol−1, respectively. The proposed biosensor is considered to be a promising model for the detection of Met.