To evaluate and quantify the planning performance of automatic planning (AP) with manual planning (MP) for nasopharyngeal carcinoma in the RayStation treatment planning system (TPS). A progressive and effective design method for AP of nasopharyngeal carcinoma was realized through automated scripts in this study. A total of 30 patients with nasopharyngeal carcinoma with initial treatment was enrolled. The target coverage, conformity index (CI), homogeneity index (HI), organs at risk sparing, and the efficiency of design and execution were compared between automatic and manual volumetric modulated arc therapy (VMAT) plans. The results of the 2 design methods met the clinical dose requirement. The differences in D95 between the 2 groups in PTV1 and PTV2 showed statistical significance, and the MPs are higher than APs, but the difference in absolute dose was only 0.21% and 0.16%. The results showed that the conformity index of planning target volumes (PTV1, PTV2, PTVnd and PGTVnx+rpn [PGTVnx and PGTVrpn]), homogeneity index of PGTVnx+rpn, and HI of PTVnd in APs are better than that in MPs. For organs at risk, the APs are lower than the MPs, and the difference was statistically significant (P < .05). The manual operation time in APs was 83.21% less than that in MPs, and the computer processing time was 34.22% more. IronPython language designed by RayStation TPS has clinical application value in the design of automatic radiotherapy plan for nasopharyngeal carcinoma. The dose distribution of tumor target and organs at risk in the APs was similar or better than those in the MPs. The time of manual operation in the plan design showed a sharp reduction, thus significantly improving the work efficiency in clinical application.
Background: Neural-network methods have been widely used for the prediction of dose distributions in radiotherapy. However, the prediction accuracy of existing methods may be degraded by the problem of dose imbalance. In this work, a new loss function is proposed to alleviate the dose imbalance and achieve more accurate prediction results. The U-Net architecture was employed to build a prediction model. Our study involved a total of 110 patients with left-breast cancer, who were previously treated by volumetric-modulated arc radiotherapy. The patient dataset was divided into training and test subsets of 100 and 10 cases, respectively. We proposed a novel ‘sharp loss’ function, and a parameter γ was used to adjust the loss properties. The mean square error (MSE) loss and the sharp loss with different γ values were tested and compared using the Wilcoxon signed-rank test. Results: The sharp loss achieved superior dose prediction results compared to those of the MSE loss. The best performance with the MSE loss and the sharp loss was obtained when the parameter γ was set to 100. Specifically, the mean absolute difference values for the planning target volume were 318.87 ± 30.23 for the MSE loss versus 144.15 ± 16.27 for the sharp loss with γ = 100 (p < 0.05). The corresponding values for the ipsilateral lung, the heart, the contralateral lung, and the spinal cord were 278.99 ± 51.68 versus 198.75 ± 61.38 (p < 0.05), 216.99 ± 44.13 versus 144.86 ± 43.98 (p < 0.05), 125.96 ± 66.76 versus 111.86 ± 47.19 (p > 0.05), and 194.30 ± 14.51 versus 168.58 ± 25.97 (p < 0.05), respectively. Conclusions: The sharp loss function could significantly improve the accuracy of radiotherapy dose prediction.
Background and Purpose: Artificial intelligence (AI) is a technique which tries to think like humans and mimic human behaviors. It has been considered as an alternative in a lot of human-dependent steps in radiotherapy (RT), since the human participation is a principal uncertainty source in RT. The aim of this work is to provide a systematic summary of the current literature on AI application for RT, and to clarify its role for RT practice in terms of clinical views. Materials and Methods: A systematic literature search of PubMed and Google Scholar was performed to identify original articles involving the AI applications in RT from the inception to 2022. Studies were included if they reported original data and explored the clinical applications of AI in RT. Results: The selected studies were categorized into three aspects of RT: organ and lesion segmentation, treatment planning and quality assurance. For each aspect, this review discussed how these AI tools could be involved in the RT protocol. Conclusions: Our study revealed that AI was a potential alternative for the human-dependent steps in the complex process of RT.
Fully convolutional networks were developed for predicting optimal dose distributions for patients with left-sided breast cancer and compared the prediction accuracy between two-dimensional and three-dimensional networks. Sixty cases treated with volumetric modulated arc radiotherapy were analyzed. Among them, 50 cases were randomly chosen to conform the training set, and the remaining 10 were to construct the test set. Two U-Net fully convolutional networks predicted the dose distributions, with two-dimensional and three-dimensional convolution kernels, respectively. Computed tomography images, delineated regions of interest, or their combination were considered as input data. The accuracy of predicted results was evaluated against the clinical dose. Most types of input data retrieved a similar dose to the ground truth for organs at risk (p > 0.05). Overall, the two-dimensional model had higher performance than the three-dimensional model (p < 0.05). Moreover, the two-dimensional region of interest input provided the best prediction results regarding the planning target volume mean percentage difference (2.40 ± 0.18%), heart mean percentage difference (4.28 ± 2.02%), and the gamma index at 80% of the prescription dose are with tolerances of 3 mm and 3% (0.85 ± 0.03), whereas the two-dimensional combined input provided the best prediction regarding ipsilateral lung mean percentage difference (4.16 ± 1.48%), lung mean percentage difference (2.41 ± 0.95%), spinal cord mean percentage difference (0.67 ± 0.40%), and 80% Dice similarity coefficient (0.94 ± 0.01). Statistically, the two-dimensional combined inputs achieved higher prediction accuracy regarding 80% Dice similarity coefficient than the two-dimensional region of interest input (0.94 ± 0.01 vs 0.92 ± 0.01, p < 0.05). The two-dimensional data model retrieves higher performance than its three-dimensional counterpart for dose prediction, especially when using region of interest and combined inputs.
To propose a multi-output fully convolutional network (MOFCN) to segment bilateral lung, heart and spinal cord in the planning thoracic computed tomography (CT) slices automatically and simultaneously. The MOFCN includes two components: one main backbone and three branches. The main backbone extracts the features about lung, heart and spinal cord. The extracted features are transferred to three branches which correspond to three organs respectively. The longest branch to segment spinal cord is nine layers, including input and output layers. The MOFCN was evaluated on 19,277 CT slices from 966 patients with cancer in the thorax. In these slices, the organs at risk (OARs) were delineated and validated by experienced radiation oncologists, and served as ground truth for training and evaluation. The data from 61 randomly chosen patients were used for training and validation. The remaining 905 patients’ slices were used for testing. The metric used to evaluate the similarity between the auto-segmented organs and their ground truth was Dice. Besides, we compared the MOFCN with other published models. To assess the distinct output design and the impact of layer number and dilated convolution, we compared MOFCN with a multi-label learning model and its variants. By analyzing the not good performances, we suggested possible solutions. MOFCN achieved Dice of 0.95±0.02 for lung, 0.91±0.03 for heart and 0.87±0.06 for spinal cord. Compared to other models, MOFCN could achieve a comparable accuracy with the least time cost. The results demonstrated the MOFCN’s effectiveness. It uses less parameters to delineate three OARs simultaneously and automatically, and thus shows a relatively low requirement for hardware and has potential for broad application.
22 September 2023 in Physics in Medicine & Biology
Objective . To propose lung contour deformation features (LCDFs) as a surrogate to estimate the thoracic internal target motion, and to report their performance by correlating with the changing body using a cascade ensemble model (CEM). LCDFs, correlated to the respiration driver, are employed without patient-specific motion data sampling and additional training before treatment. Approach . LCDFs are extracted by matching lung contours via an encoder–decoder deep learning model. CEM estimates LCDFs from the currently captured body, and then uses the estimated LCDFs to track internal target motion. The accuracy of the proposed LCDFs and CEM were evaluated using 48 targets’ motion data, and compared with other published methods. Main results . LCDFs estimated the internal targets with a localization error of 2.6 ± 1.0 mm (average ± standard deviation). CEM reached a localization error of 4.7 ± 0.9 mm and a real-time performance of 256.9 ± 6.0 ms. With no internal anatomy knowledge, they achieved a small accuracy difference (of 0.34∼1.10 mm for LCDFs and of 0.43∼1.75 mm for CEM at the 95% confidence level) with a patient-specific lung biomechanical model and the deformable image registration models. Significance . The results demonstrated the effectiveness of LCDFs and CEM on tracking target motion. LCDFs and CEM are non-invasive, and require no patient-specific training before treatment. They show potential for broad applications.