With modern power utilities going green by utilising renewable energy technologies and the development of the smart power grid, high‐voltage direct current (HVDC) technologies become more and more important in the energy transmission. In particular, HVDC cable systems play a prominent role in undersea power transmission and offshore renewable energy integration. As an essential part of a complete HVDC cable system, the cable termination is one of the most critical components. The mathematical and physical background of HVDC cable systems is discussed and the development of various types of HVDC cable terminations is reviewed. Regarding the non‐uniform field distribution, the influence of temperature on the non‐linear conductivity is briefly discussed. Furthermore, faults of terminations caused by inappropriate installation and testing of cable systems are discussed.
This study sets out to discuss the challenges that need to be addressed effectively to facilitate the adoption of long distance high‐voltage and ultra‐high‐voltage direct current (UHVDC) power transmission cables. As in the alternating current case, the desire to minimise the losses has involved the use of increasingly high transmission voltages, which presents particular problems where UHVDC cables are concerned. Specifically, this study presents the case for a novel, integrated approach to the problem, which links three distinct aspects of the problem, namely: (i) cable ratings and network operability; (ii) cable design and constituent insulating material requirements; and (iii) potential strategies for the design of novel insulation materials, where the required properties are actively ‘designed in’. The study concludes that the impact of these factors acting in concert on network operation/performance requires a more integrated approach to the problem than has traditionally been the case. A number of complementary strategies for the development of novel material technologies and UHVDC cable designs are required that can meet the service performance and ultimate service lifetimes expected for new network applications.
28 September 2015 in IEEE Transactions on Power Delivery
Due to the rapid development of the voltage-source converter (VSC), the demands for HVDC cables have increased significantly. Although more than ten VSC-HVDC projects are under construction and many more are in operations globally, the testing criteria for HVDC XLPE cables are mainly referenced to test guideline TB 496 recommended by CIGRE. Due to the large stray capacitance of the VSC-HVDC cables, the switching impulse overvoltage stress of the cables is the main electrical parameter concerned, a unified overvoltage factor of 2.1 p.u. being generally accepted. However, the switching impulse overvoltage stress of a VSC-HVDC cable system depends on not only the VSC topology but also the cable parameters and the volt-ampere characteristics of the dc cable surge arresters used. This paper studies the switching impulse overvoltage stresses for the dc cable system of a symmetrical monopole VSC-HVDC transmission system using the modular multilevel converter technology. The studies were performed according to the key technical parameters for a typical 1000-MW/320-kV VSC-HVDC transmission scheme, the XLPE dc cable links being assumed. The results show that a switching impulse overvoltage level of 2.3 p.u. should be applied during the type test of the overvoltage capability of the HVDC cables.
The most critical positions of a prefabricated cable accessory, from the electrical point of view, are the interfaces between the stress cone and its surroundings. Accordingly, the contact pressure on those interfaces needs to be carefully designed to assure both good dielectric strength and smooth installation of the stress cone. Nevertheless, since stress cones made from rubber are under large deformation after installation, their internal stress distribution is neither practical to measure directly by planting sensors, nor feasible to compute accurately with the conventional theory of linear structural mechanics. This paper presents one sophisticated method for computing the mechanical stress distribution in rubber stress cones of cable accessories by employing hyperelastic models in a computation model based on the finite element method. This method offers accurate results for rubber bodies of complex geometries and large deformations. Based on the method, a case study of a composite prefabricated termination for extruded cables is presented, and the sensitivity analysis is given as well.
Today's power utilities are evolving towards a more environment-friendly form. Particularly, in undersea power transmission, offshore renewable energy integration and urban power transmission, HVDC cable systems play a significant role. As an essential part of the cable systems, cable joints are often the weakest and the most critical point. Hence, the safe operation of cable joints under different operational stages is one of the key issues to make the cable systems reliable. In this paper, the development of HVDC cable joints has been reviewed. The design aspects, including geometry, insulation materials and interfaces are briefly discussed.
The interface between cable insulation and stress cone is commonly regarded as the most critical area of a prefabricated cable accessory. To enhance the overall performance, the contact pressure on the interface should be carefully designed. Linear material models are widely used in the industry to estimate the deformation of stress cone, but this method can hardly offer an accurate estimation for deformation above 5% because rubbers conform more to the non-linear material at this elongation range. This paper proposed a method, based on the hyperelastic model (Mooney-Rivlin) fitted from the uniaxial tensile test data. Compared to the present ones, this method offers a more accurate estimation of deformation above 10%, and therefore, helps in the verification of stress cone design and indirectly improves the reliability of high voltage cable accessories.