Objectives. To investigate and compare postoperative pain after one-visit root canal treatment (RCT) on teeth with vital pulps using three different obturation techniques. Study Design. Two hundred and four patients (105 men and 99 women) aged 12 to 77 years were randomly assigned into three treatments groups: cold lateral compaction of gutta-percha (LC), Thermafil technique (TT), and Backfill - Thermafil obturation technique (BT). Postoperative pain was recorded on a visual analogue scale (VAS) of 0 - 10 after 2 and 6 hours, and 1, 2, 3, 4, 5, 6 and 7 days. Data were statistically analyzed using multivariate logistic regression analysis. Results. In the total sample, 87% of patients experienced discomfort or pain in some moment between RCT and the seventh day. The discomfort experienced was weak, light, moderate and intense in 6%, 44%, 20% and 6% of the cases, respectively. Mean pain levels were 0.4 ± 0.4, 0.4 ± 0.3, and 1.4 ± 0.7 in LC, BT, and TT groups, respectively. Patients of TT group experienced a significantly higher mean pain level compared to other two groups (p < 0.0001). In TT group, all patients felt some level of pain at six hours after RCT. Conclusions. Postoperative pain was significantly associated with the obturation technique used during root canal treatment. Patients whose teeth were filled with Thermafil obturators (TT technique) showed significantly higher levels of discomfort than patients whose teeth were filled using any of the other two techniques.
To analyze and compare the accuracy and root contact prevalence, comparing a conventional freehand technique and two navigation techniques based on augmented reality technology for the orthodontic self-drilling mini-implants placement. Methods Two hundred and seven orthodontic self-drilling mini-implants were placed using either a conventional freehand technique (FHT) and two navigation techniques based on augmented reality technology (AR TOOTH and AR SCREWS). Accuracy across different dental sectors was also analyzed. CBCT and intraoral scans were taken both prior to and following orthodontic self-drilling mini-implants placement. The deviation angle and horizontal were then analyzed; these measurements were taken at the coronal entry point and apical endpoint between the planned and performed orthodontic self-drilling mini-implants. In addition, any complications resulting from mini-implant placement, such as spot perforations, were also analyzed across all dental sectors.Results The statistical analysis showed significant differences between study groups with regard to the coronal entry-point (p < 0.001), apical end-point(p < 0.001) and angular deviations (p < 0.001). Furthermore, statistically significant differences were shown between the orthodontic self-drilling mini-implants placement site at the coronal entry-point (p < 0.0001) and apical end-point (p < 0.001). Additionally, eight root perforations were observed in the FHT group, while there were no root perforations in the two navigation techniques based on augmented reality technology.Conclusions The navigation techniques based on augmented reality technology has an effect on the accuracy of orthodontic self-drilling mini-implants placement and results in fewer intraoperative complications, comparing to the conventional free-hand technique. The AR TOOTH augmented reality technique showed more accurate results between planned and placed orthodontic self-drilling mini-implants, comparing to the AR SCREWS and conventional free-hand techniques. The navigation techniques based on augmented reality technology showed fewer intraoperative complications, comparing to the conventional free-hand technique.
Purpose: To analyze the influence of the pecking motion frequency on the cyclic fatigue resistance of endodontic rotary files. Material and Methods: Sixty PlexV 25.06 endodontic rotary files were selected and distributed into three groups: 30 movements/min (n = 20), 60 movements/min (n = 20), and 120 movements/min (n = 20). A dynamic cyclic fatigue device was designed using Computer Aided Design/ Computer Aided Engineering (CAD/CAE) technology and manufactured by 3D impressions to simulate the pecking motion performed by an operator. Failures of the endodontic rotary files were detected by a Light-Emitting Diode (LED)/Light-Dependent Resistor (LDR) system controlled by an Arduino-Driver complex and management software. Endodontic rotary files were tested on an artificial root canal manufactured by wire electrical discharge machining (EDM), with similar dimensions to those of the instrument under examination. Endodontic rotary files were used following the manufacturer’s recommendations. The results were analyzed by ANOVA and Weibull statistics. Results: All pairwise comparisons revealed statistically significant differences in all three variables, except for the difference in the number of cycles between the groups with 60 and 120 movements/min (p = 0.298). The scale distribution parameter of Weibull statistics showed statistically significant differences in all three variables, except for the differences in the number of cycles between groups with 30 and 60 movements/min (p = 0.0722). No statistically significant differences in the three variables were observed for the shape distribution parameter. Conclusion: A low frequency of pecking motion is recommended to reduce the risk of failure of endodontic rotary files associated with cyclic fatigue.
1
1 January 2018 in Journal of Clinical and Experimental Dentistry
The incidence of endodontic infections is high. The contribution of Endodontics to the global problem of antibiotic resistance could be significant. The ESE, together with the World Health Organization, are promoting the World Antibiotic Awareness Week (13-19 November 2017) to promote the appropriate use of systemic antibiotics in Endodontics. The objective of this study was to determine the prescription pattern of antibiotics in the treatment of endodontic infections of Spanish dentists attending specialization programs in Endodontics. Dentists from five Spanish endodontic postgraduate programs were requested to answer a one-page questionnaire surveying about antibiotics indications. Seventy-three dentists were required to participate in this investigation, and 67 (91.2%) fulfilled satisfactorily the survey and were included in the study. Data were analyzed using descriptive statistics and chi square test. The average duration of antibiotic therapy was 6.8±1.2 days. All respondents chose amoxicillin as first choice antibiotic in patients with no medical allergies, alone (40%) or associated to clavulanic acid (60%). The first drug of choice for penicillin allergic patients was clindamycin (72%). For cases of irreversible pulpitis, 22% of respondents prescribed antibiotics. For the scenario of a necrotic pulp, symptomatic apical periodontitis and no swelling, 37% prescribed antibiotics. A quarter of dentists prescribed antibiotics for necrotic pulps with asymptomatic apical periodontitis and a sinus tract. The results of this study show that postgraduate training in Endodontics provides greater awareness of the correct indications of antibiotics. Dentists who have received specialized training in Endodontics have a prescription pattern of antibiotics more adjusted to the guidelines recommended by international organizations and by scientific societies. Key words:Antibiotics, apical periodontitis, dental curriculum, endodontic infections, postgraduate endodontic training.