This in vitro study compares the fluoride release from microlaminated glass ionomer based on glass hybrid technology coated with two different surface coating agents. A total of 18 samples were divided into three groups of six samples each: (1) glass ionomer Equia Forte Fil coated with Equia Forte Coat (Equia+EC), (2) glass ionomer Equia Forte Fil coated with GC Fuji Varnish (Equia+VC) and (3) uncoated glass ionomer Equia Forte (EQUIA cont). Fluoride release was measured using an ion-selective electrode (ORION EA 940) after 24 hours, 4 days, 30 days and 64 days. Repeated measures ANOVA, multiple comparisons, Tukey's test and paired t-test were used to test the differences between the groups. The differences between the groups and four time points were statistically significant (ANOVA, p<0.0001). Cumulative fluoride ion release after 64 days was 66.01 mg/l, 123.54mg/l and 203.22 mg/l for EQUIA+EC, EQUIA+VC and EQUIA cont, respectively. All the differences were statistically significant except the difference between EQUIA+VC and EQUIA cont after 24 hours. The amount of released fluoride was significantly lower in the samples coated with nanofilled surface coating agent compared to the samples coated with varnish and uncoated samples.
Objective: The objective was to compare the efficacy of three different lasers in disinfection of root canals inoculated with Enterococcus faecalis and Candida albicans biofilms. Background: Endodontic space disinfection depends on the type of root canal irrigant used and the way it is delivered and agitated because irrigants have limited ability to reach all parts of root canal system. Materials and methods: Thirty single-rooted human teeth were selected. Root canals were instrumented and root surfaces were sealed using adhesive and the apical openings with adhesive and composite resin. Roots were fixed in Eppendorf tubes and sterilized in autoclave. The specimens were randomly divided into three experimental groups ( n = 10) and inoculated with E. faecalis and C. albicans . After 7 days of incubation period, the number of E. faecalis and C. albicans colony-forming units (CFUs) was determined for each root canal. In the first experimental group, Er:YAG laser (0.3 W) with photon-induced photoacoustic streaming technique was used for root canal disinfection, in the second, Nd:YAG laser (1.5 W), and in the third, Er,Cr:YSGG (1.25 W) laser was used. After different root canal disinfection protocols, the number of E. faecalis and C. albicans CFUs was determined again for each root canal. Results: Er:YAG and Er,Cr:YSGG lasers eradicated significant number of E. faecalis and C. albicans CFUs ( p < 0.05), while Nd:YAG laser irradiation did not result in statistically significant reduction ( p > 0.05). Er,Cr:YSGG laser eradicated significantly more microorganisms in comparison with Er:YAG laser ( p < 0.05). Conclusions: Er,Cr:YSGG laser was the most efficient tool in eradication of E. faecalis and C. albicans biofilms.
To determine the mechanical properties of hybrid and high-viscosity glass ionomer cements. Compressive strength and hardness of three glass ionomer cements (GIC) were measured: Ketac ™ Universal Aplicap ™, EQUIA Fil® and EQUIA FORTE Fil®, and the SEM sample analysis were performed. The samples for measuring the compressive strength were prepared using silicone molds with standard dimensions of 6 mm x 4 mm and stored in deionized water for five days, while the samples for hardness measurement were prepared using Teflon molds with a cylindrical opening in the middle, dimensions 2 mm in height and 5 mm in width. For each material, one sample was made (n = 1) and stored in deionized water at 37ºC for 25 days. A representative sample of each material was analyzed using SEM. For the comparison of obtained values, the ANOVA test was used, while Tukey test was used for the multiple comparison. There were no significant differences between the compressive strength of the three tested materials (p <0.05). The hardness values were: 157 HV0,2 for Ketac ™ Universal Aplicap ™, 47 HV0,2 for EQUIA Fil® and 39 HV0,2 for EQUIA FORTE Fil®, respectively, and were significantly different, implying that Ketac ™ Universal Aplicap ™ has much higher hardness values than the other materials tested. SEM sample analysis revealed similar fracture modes of the tested materials. It was concluded that there were no statistically significant differences in compressive strength and fracture modes between the tested materials, while Ketac ™ Universal Aplicap ™ hardness results were significantly higher than the ones measured for EQUIA Fil® and EQUIA FORTE Fil®.