Ammonia (NH3) emission is one of the major environmental issues in livestock farming. Gas measurements are required to study the emission process, to establish emission factors, and to assess the efficiency of emission reduction techniques. However, the current methods for acquiring reference measurements of NH3 are either high in cost or labor intensive. In this study, a cost-effective ammonia monitoring system (AMS) was constructed from a commercially-available gas analyzing module based on tunable diode laser absorption (TDLA) spectroscopy. To cope with the negative measurement biases caused by differing inlet pressures, a set of correction equations was formulated. Field validation of the AMS on NH3 measurement was conducted in a fattening pig barn, where the system was compared to a Fourier-transform infrared (FTIR) spectroscopy analyzer. Under two test conditions in a fattening pig barn, the absolute error of the AMS measurements with respect to the average obtained values between the AMS and the FTIR was respectively 0.66 and 0.08 ppmv, corresponding to 5.9% and 0.5% relative error. Potential sources of the measurement uncertainties in both the AMS and FTIR were discussed. The test results demonstrated that the AMS was capable of performing high-quality measurement with sub-ppm accuracy, making it a promising cost-effective tool for establishing NH3 emission factors and studying NH3 emission processes in pig houses.
Ammonia emissions are an important issue in livestock production. Many mitigation measures have been proposed in order to reduce the environmental impact of livestock farms, and reliable field measurements are required to evaluate the amount of released or reduced ammonia while applying these measures. Following the guideline of the Verification of Environmental Technologies for Agricultural Production test protocol, five commercially available gas analysers, i.e., INNOVA 1314, Picarro G2103, Rosemount CT5100, Gasmet CX4000, and Axetris LGD F200-A, were validated as alternative methods to the wet-chemistry method (reference method) for measuring ammonia in livestock houses. High correlations ( ) were found between the analysers and the reference method. The measurement errors of the tested analysers were below 2 ppmv or 10%. Equivalence to the wet-chemistry method was demonstrated for the INNOVA and Rosemount analysers without a recalibration and for the Picarro and Axetris analysers with a recalibration. The Gasmet analyser was seemingly subjected to an interference from carbon-dioxide and, after compensating for the cross-sensitivity, the equivalence to the wet-chemistry method could also be demonstrated. Calibration curves that were based on a certified gas cylinder were inconsistent with that based on wet-chemistry measurements, which suggested that field calibration might be necessary for optimal measurement accuracy.
A barn’s climate is vital for animal welfare and emissions control, including greenhouse gases like methane (CH4) and carbon dioxide (CO) and environmental gases like ammonia (NH). The goal of this study was to investigate a developed low-cost online tool for monitoring barn climate and air pollutant emissions (OTICE) in naturally ventilated barns. OTICE employed a wireless sensor network with low-cost sensors for gases and climate variables, allowing scalable use across multiple barns. We evaluated the sensors for CO, NH, and CH4 for accuracy, both in controlled lab conditions and in a dairy barn in Germany, where measurements were carried out continuously for a duration of 12 days. For the averaged concentration levels over the measurement period, the low-cost sensors agreed well with the reference system, with relative deviations lower than 7% for all three gases, with maximum peak deviations up to 32% for CO, 67% for NH, and 65% for CH, with strong Spearman correlations for CO and NH ( = 0.8, = 0.68) and a rather weak correlation for CH4 with = 0.24. Further calibration and stability investigations are required, especially for CH4 sensing. However, the overall good results for NH and especially CO measurements indicate a huge potential of the low-cost system as a valuable tool for monitoring relative NH emission levels and the measurement of air exchange rates in naturally ventilated barns.