Robin Fabian Gohmann

Dr. Robin Fabian Gohmann

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in JACC: Cardiovascular Imaging
Verified
Journal Article
Open access
RGRobin Fabian Gohmann
Robin Fabian Gohmann
KPKonrad Pawelka
Konrad Pawelka
PSPatrick Seitz
Patrick Seitz
NMNicolas Majunke
Nicolas Majunke
LHLinda Heiser
Linda Heiser
MGMatthias Gutberlet
Matthias Gutberlet
The purpose of this study was to analyze the ability of machine-learning (ML)-based computed tomography (CT)-derived fractional flow reserve (CT-FFR) to further improve the diagnostic performance of coronary CT angiography (cCTA) for ruling out significant coronary artery disease (CAD) during pre-transcatheter aortic valve replacement (TAVR) evaluation in patients with a high pre-test probability for CAD. CAD is a frequent comorbidity in patients undergoing TAVR. Current guidelines recommend its assessment before TAVR. If significant CAD can be excluded on cCTA, invasive coronary angiography (ICA) may be avoided. Although cCTA is a very sensitive test, it is limited by relatively low specificity and positive predictive value, particularly in high-risk patients. Overall, 460 patients (age 79.6 ± 7.4 years) undergoing pre-TAVR CT were included and examined with an electrocardiogram-gated CT scan of the heart and high-pitch scan of the vascular access route. Images were evaluated for significant CAD. Patients routinely underwent ICA (388/460), which was omitted at the discretion of the local Heart Team if CAD could be effectively ruled out on cCTA (72/460). CT examinations in which CAD could not be ruled out (CAD+) (n = 272) underwent additional ML-based CT-FFR. ML-based CT-FFR was successfully performed in 79.4% (216/272) of all CAD+ patients and correctly reclassified 17 patients as CAD negative. CT-FFR was not feasible in 20.6% because of reduced image quality (37/56) or anatomic variants (19/56). Sensitivity, specificity, positive predictive value, and negative predictive value were 94.9%, 52.0%, 52.2%, and 94.9%, respectively. The additional evaluation with ML-based CT-FFR increased accuracy by Δ+3.4% (CAD+: Δ+6.0%) and raised the total number of examinations negative for CAD to 43.9% (202/460). ML-based CT-FFR may further improve the diagnostic performance of cCTA by correctly reclassifying a considerable proportion of patients with morphological signs of obstructive CAD on cCTA during pre-TAVR evaluation. Thereby, CT-FFR has the potential to further reduce the need for ICA in this challenging elderly group of patients before TAVR.

Verified
Journal Article
Open access
PDF file
RGRobin Fabian Gohmann
Robin Fabian Gohmann
PLPhilipp Lauten
Philipp Lauten
PSPatrick Seitz
Patrick Seitz
CKChristian Krieghoff
Christian Krieghoff
CLChristian Lücke
Christian Lücke
MGMatthias Gutberlet
Matthias Gutberlet
Background: Significant coronary artery disease (CAD) is a common finding in patients undergoing transcatheter aortic valve implantation (TAVI). Assessment of CAD prior to TAVI is recommended by current guidelines and is mainly performed via invasive coronary angiography (ICA). In this study we analyzed the ability of coronary CT-angiography (cCTA) to rule out significant CAD (stenosis ≥ 50%) during routine pre-TAVI evaluation in patients with high pre-test probability for CAD. Methods: In total, 460 consecutive patients undergoing pre-TAVI CT (mean age 79.6 ± 7.4 years) were included. All patients were examined with a retrospectively ECG-gated CT-scan of the heart, followed by a high-pitch-scan of the vascular access route utilizing a single intravenous bolus of 70 mL iodinated contrast medium. Images were evaluated for image quality, calcifications, and significant CAD; CT-examinations in which CAD could not be ruled out were defined as positive (CAD+). Routinely, patients received ICA (388/460; 84.3%; Group A), which was omitted if renal function was impaired and CAD was ruled out on cCTA (Group B). Following TAVI, clinical events were documented during the hospital stay. Results: cCTA was negative for CAD in 40.2% (188/460). Sensitivity, specificity, PPV, and NPV in Group A were 97.8%, 45.2%, 49.6%, and 97.4%, respectively. Median coronary artery calcium score (CAC) was higher in CAD+-patients but did not have predictive value for correct classification of patients with cCTA. There were no significant differences in clinical events between Group A and B. Conclusion: cCTA can be incorporated into pre-TAVI CT-evaluation with no need for additional contrast medium. cCTA may exclude significant CAD in a relatively high percentage of these high-risk patients. Thereby, cCTA may have the potential to reduce the need for ICA and total amount of contrast medium applied, possibly making pre-procedural evaluation for TAVI safer and faster.

1 September 2023 in European Radiology
Verified
Journal Article
Open access
PDF file
TSTobias Schönfeld
Tobias Schönfeld
PSPatrick Seitz
Patrick Seitz
CKChristian Krieghoff
Christian Krieghoff
SPSlavica Ponorac
Slavica Ponorac
AWAlexander Wötzel
Alexander Wötzel
RGRobin Fabian Gohmann
Robin Fabian Gohmann
Objective: To investigate the feasibility and image quality of high-pitch CT pulmonary angiography (CTPA) with reduced iodine volume in normal weight patients. Methods: In total, 81 normal weight patients undergoing CTPA for suspected pulmonary arterial embolism were retrospectively included: 41 in high-pitch mode with 20 mL of contrast medium (CM); and 40 with normal pitch and 50 mL of CM. Subjective image quality was assessed and rated on a 3-point scale. For objective image quality, attenuation and noise values were measured in all pulmonary arteries from the trunk to segmental level. Contrast-to-noise ratio (CNR) was calculated. Radiation dose estimations were recorded. Results: There were no statistically significant differences in patient and scan demographics between high-pitch and standard CTPA. Subjective image quality was rated good to excellent in over 90% of all exams with no significant group differences (p = 0.32). Median contrast opacification was lower in high-pitch CTPA (283.18 [216.06–368.67] HU, 386.81 [320.57–526.12] HU; p = 0.0001). CNR reached a minimum of eight in all segmented arteries, but was lower in high-pitch CTPA (8.79 [5.82–12.42], 11.01 [9.19–17.90]; p = 0.005). Median effective dose of high-pitch CTPA was lower (1.04 [0.72–1.27] mSv/mGy·cm; 1.49 [1.07–2.05] mSv/mGy·cm; p < 0.0001). Conclusion: High-pitch CTPA using ultra-low contrast volume (20 mL) rendered diagnostic images for the detection of pulmonary arterial embolism in most instances. Compared to standard CTPA, the high-pitch CTPA exams with drastically reduced contrast medium volume had also concomitantly reduced radiation exposure. However, objective image quality of high-pitch CTPA was worse, though likely still within acceptable limits for confident diagnosis. Clinical relevance: This study provides valuable insights on the performance of a high-pitch dual-source CTPA protocol, offering potential benefits in reducing contrast medium and radiation dose while maintaining sufficient image quality for accurate diagnosis in patients suspected of pulmonary embolism. Key Points: • High-pitch CT pulmonary angiography (CTPA) with ultra-low volume of contrast medium and reduced radiation dose renders diagnostic examinations with comparable subjective image quality to standard CTPA in most patients. • Objective image quality of high-pitch CTPA is reduced compared to standard CTPA, but contrast opacification and contrast-to-noise ratio remain above diagnostic thresholds. • Challenges of high-pitch CTPA may potentially be encountered in patients with severe heart failure or when performing a Valsalva maneuver during the examination.

1 July 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
RGRobin Fabian Gohmann
Robin Fabian Gohmann
CBChristian Bluem
Christian Bluem
MZM. Zvyagintsev
M. Zvyagintsev
VMV. Mainz
V. Mainz
HCH. Clusmann
H. Clusmann
CMC.A. Mueller
C.A. Mueller

28 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RGRobin Fabian Gohmann
Robin Fabian Gohmann
PSPatrick Seitz
Patrick Seitz
KPKonrad Pawelka
Konrad Pawelka
NMNicolas Majunke
Nicolas Majunke
ASAdrian Schug
Adrian Schug
MGMatthias Gutberlet
Matthias Gutberlet
Background: Coronary artery disease (CAD) is a frequent comorbidity in patients undergoing transcatheter aortic valve implantation (TAVI). If significant CAD can be excluded on coronary CT-angiography (cCTA), invasive coronary angiography (ICA) may be avoided. However, a high plaque burden may make the exclusion of CAD challenging, particularly for less experienced readers. The objective was to analyze the ability of machine learning (ML)-based CT-derived fractional flow reserve (CT-FFR) to correctly categorize cCTA studies without obstructive CAD acquired during pre-TAVI evaluation and to correlate recategorization to image quality and coronary artery calcium score (CAC). Methods: In total, 116 patients without significant stenosis (≥50% diameter) on cCTA as part of pre-TAVI CT were included. Patients were examined with an electrocardiogram-gated CT scan of the heart and high-pitch scan of the torso. Patients were re-evaluated with ML-based CT-FFR (threshold = 0.80). The standard of reference was ICA. Image quality was assessed quantitatively and qualitatively. Results: ML-based CT-FFR was successfully performed in 94.0% (109/116) of patients, including 436 vessels. With CT-FFR, 76/109 patients and 126/436 vessels were falsely categorized as having significant CAD. With CT-FFR 2/2 patients but no vessels initially falsely classified by cCTA were correctly recategorized as having significant CAD. Reclassification occurred predominantly in distal segments. Virtually no correlation was found between image quality or CAC. Conclusions: Unselectively applied, CT-FFR may vastly increase the number of false positive ratings of CAD compared to morphological scoring. Recategorization was virtually independently from image quality or CAC and occurred predominantly in distal segments. It is unclear whether or not the reduced CT-FFR represent true pressure ratios and potentially signifies pathophysiology in patients with severe aortic stenosis.

1 February 2021 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
RGRobin Fabian Gohmann
Robin Fabian Gohmann
SGSebastian Gottschling
Sebastian Gottschling
PSPatrick Seitz
Patrick Seitz
BTBatuhan Temiz
Batuhan Temiz
CKChristian Krieghoff
Christian Krieghoff
MGMatthias Gutberlet
Matthias Gutberlet
Background: Adipose tissue as part of body composition analysis may serve as a powerful biomarker. Validation of segmented adipose tissue and correlation to clinical data has been performed on non-enhanced scans (NES). As many patients require a contrast enhanced scan (CES) for other aspects of clinical decision making, the utility of CES for body composition analysis would be most useful. Therefore, we analyzed the influence of iodinated contrast medium (ICM) and contrast phase on the characterization and segmentation of adipose tissue. Methods: Exams of 31 patients undergoing multi-phasic CT at identical scan settings containing an NES were retrospectively included. In addition to NES, patients received an arterial (ART) (n=23), portal-venous (PVN) (n=10), and/or venous scan (VEN) (n=31) after intravenous injection of 90 mL ICM. Density and volume of adipose tissue were quantified semi-automatically with thresholds between −190 HU and −30 HU and recorded separately for visceral (VAT) and subcutaneous adipose tissue (SAT). Density and volume of total adipose tissue (TAT) were computed. For conversion of values from CES into those of NES regression analyses were performed and tested. Results: Density of adipose tissue increased after application of ICM more on later scans (VEN ≈ PVN > ART) and more markedly in VAT than SAT (VAT > TAT > SAT). Except in SAT on ART, all changes were significant (P ART) (P TAT) on all CES (P<0.05). Density and volume in CES correlate extremely well with NES and may be calculated from one another [root-mean-square error (RMSE): <6 HU; <0.85 dm3]. Conclusions: Density and volume of segmented adipose tissue are altered by the injection of ICM in differing degrees between compartments and contrast phases. However, as the effect of ICM is fairly constant for a given compartment and contrast phase, values may be converted into those of NES with relative precession. This conversion allows body composition analysis to be carried out also in contrast enhanced CT examinations, e.g., for risk stratification and the comparison of the obtained results to previous studies.