Vortex flow meters are used to measure the flow of gases and liquids. The flow meters of this type measure the frequency of vortices that arise behind an obstacle set in the path of the flowing fluid. The frequency is a function of the speed of the flowing fluid. This obstacle is called the vortex shedder bar. The advantage of this solution is that the frequency of vortices does not viscose on the rheological properties of the fluid, such as viscosity or density. As a result, the indications of the vortex flowmeter do not depend on the temperature and type of fluid. The work includes numerical and experimental studies of the effect of changing the shape of a vortex generator on the stability of vortex generation in a vortex flowmeter. The article presents a numerical analysis of the influence of selected surfaces of the vortex shedder on the parameters of the vortex flowmeter. In order to determine the influence of the shape of the vortex shedder on the type of generated vortices, simulations were carried out for various flow velocities. Numerical calculations were experimentally verified for a cylinder-shaped vortex shedder. The experimental tests consist in determining the velocity field behind the vortex shedder. For this purpose, a proprietary method of determining local liquid velocities and the visualization of local vortices were used. On the basis of the conducted research, the influence of the shape of the vortex shedder on the width of the von Karman vortex street was determined and the optimal longitudinal distance from the shedder was determined in which it is most useful to measure the frequency of the vortices. This place ensures the stability of the frequency of the generated vortices.
Flow measurements that utilize differential pressure meters are commonly applied in industry. In such conditions, gas flow is often accompanied by liquid condensation. For this reason, errors occur in the metering process that can be attributed to the fluctuations in continuous phase parameters in the flow. Furthermore, the occurrence of a dispersed phase results in flow disturbance and dynamic pressure pulsations. For the above reasons, new methods and tools are sought with the purpose of performing measurements of gas-liquid flows providing measurement results that can be considered as fairly accurate in the cases when flow involves a liquid phase form. The paper reports the results of a study involving measurement of wet gas flow using differential pressure flowmeters. The experiments were conducted for three constant mass air flow rates equal to 0.06, 0.078 and 0.086 kg/s. After stabilization of the air flow rates, water was fed into the pipe with flow rates in the range from 0.01 to 0.16 kg/s. The research involved a standard orifice and three types of slotted orifices with various slot arrangements and geometries. The analysis focused on the effect of orifice geometry on the flow metering results. On the basis of the results, it was found that the slotted orifice generates smaller differential pressure values compared to the standard orifice. The water mass fraction in the gas leads to overestimated results of measurements across the flowmeter. Regardless of the type of the orifice, is necessary to undertake a correction of the results. The paper proposes a method of gas mass flow correction. The results were compared with the common over-reading correction models available in the literature.
The paper presents a new design solution for the multi-cylinder compressed air engine, described in the PL 216801 patent. A characteristic feature of the engine is its double-piston operation with pistons working in pairs in opposition and a reciprocating movement in toroidal cylinders. The energy of compressed air was used more effectively in the described engine than in the solutions known so far. Comparing the engine built in accordance with the PL 216801 patent with the parameters of the MP165 and MP3000 engines, lower air consumption in relation to the power generated on the shaft is demonstrated. The described engine uses only one crankshaft and one straight complex shaft, which constitutes an innovative combination of pistons, while maintaining the same engine operation as in the case of two crankshafts operating with phase shift and working chamber shift. Such a solution results in a reduction in the harmful space occurring at the beginning of the power stroke to the value close to “zero”—the necessity to maintain the minimum distance between the pistons working in one cylinder when they are at their closest exists only to for the sake of collision-free operation—which is very desirable for the compressed engine operating with a shift of the working chamber. The mechanical efficiency of the engine has also been improved by guiding the pistons on the complex shaft, and the number of kinematic nodes was decreased by applying only three connecting rods supporting six pistons, which also makes it possible to improve the power and mass relation by approximately 25% in comparison with the currently known engines of similar power.
15 December 2019 in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
The differential pressure of gas measurement is very often used in industrial measurements. During the gas flow, liquid condensation often occurs. The result is that when measuring a gas flow, the gas-liquid mixture is essentially measured. Errors in the indications of measuring instruments are starting to appear due to a change in the properties of the continuous phase, which is gas. In addition, the appearance of liquid droplets leads to flow disturbances and pressure pulsations. Therefore, new methods and tools for measuring the flow of gas-liquid mixture are being sought. The work involves the use of slotted orifices for measuring gas-liquid mixtures. An analysis of the influence of the slotted orifice geometry on the measurement of the biphasic mixture stream was carried out. Standard orifice and three slotted orifices of various designs. The experiment included measuring the air flow with a small amount of water dispersed in the form of drops.
1 March 2014 in Chemical and Process Engineering: New Frontiers
An optical tomograph in which a tested object is illuminated from five directions has been presented in the paper. The measurements of luminous intensity after changing into discrete signals (0 or 1) in the detectors equipped with 64 optical sensors were subjected to reconstruction by means of the matrix algorithm. Detailed description of the measuring sensor, as well as the principles of operation of the electronic system, has been given in the paper. Optical phenomena occurring at the phase boundary while transmitted through the sensor wall and phenomena inside the measuring space have also been taken into account. The method of the sensor calibration has been analysed and a way of technical solution of the problem under consideration has been discussed. The elaborated method has been tested using objects of the known shape and dimensions. It was found that reconstruction of the shapes of moving bubbles and determination of their main parameters is also possible with a reasonable accuracy.
27 February 2023 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences