Ayokunle Olanrewaju

Dr. Ayokunle Olanrewaju

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2018 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
AOAyokunle Olanrewaju
Ayokunle Olanrewaju
MBMaïwenn Beaugrand
Maïwenn Beaugrand
MYMohamed Yafia
Mohamed Yafia
DJDavid Juncker
David Juncker
Microfluidics offer economy of reagents, rapid liquid delivery, and potential for automation of many reactions, but often require peripheral equipment for flow control. Capillary microfluidics can deliver liquids in a pre-programmed manner without peripheral equipment by exploiting surface tension effects encoded by the geometry and surface chemistry of a microchannel. Here, we review the history and progress of microchannel-based capillary microfluidics spanning over three decades. To both reflect recent experimental and conceptual progress, and distinguish from paper-based capillary microfluidics, we adopt the more recent terminology of capillaric circuits (CCs). We identify three distinct waves of development driven by microfabrication technologies starting with early implementations in industry using machining and lamination, followed by development in the context of micro total analysis systems (μTAS) and lab-on-a-chip devices using cleanroom microfabrication, and finally a third wave that arose with advances in rapid prototyping technologies. We discuss the basic physical laws governing capillary flow, deconstruct CCs into basic circuit elements including capillary pumps, stop valves, trigger valves, retention valves, and so on, and describe their operating principle and limitations. We discuss applications of CCs starting with the most common usage in automating liquid delivery steps for immunoassays, and highlight emerging applications such as DNA analysis. Finally, we highlight recent developments in rapid prototyping of CCs and the benefits offered including speed, low cost, and greater degrees of freedom in CC design. The combination of better analytical models and lower entry barriers (thanks to advances in rapid manufacturing) make CCs both a fertile research area and an increasingly capable technology for user-friendly and high-performance laboratory and diagnostic tests.

11 August 2016 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
AOAyokunle Olanrewaju
Ayokunle Olanrewaju
ARA. Robillard
A. Robillard
MDM. Dagher
M. Dagher
DJD. Juncker
D. Juncker
We recently developed capillaric circuits (CCs) – advanced capillary microfluidic devices assembled from capillary fluidic elements in a modular manner similar to the design of electric circuits (Safavieh & Juncker, Lab Chip, 2013, 13, 4180–4189). CCs choreograph liquid delivery operations according to pre-programmed capillary pressure differences with minimal user intervention. CCs were thought to require high-precision micron-scale features manufactured by conventional photolithography, which is slow and expensive. Here we present CCs manufactured rapidly and inexpensively using 3D-printed molds. Molds for CCs were fabricated with a benchtop 3D-printer, poly(dimethylsiloxane) replicas were made, and fluidic functionality was verified with aqueous solutions. We established design rules for CCs by a combination of modelling and experimentation. The functionality and reliability of trigger valves – an essential fluidic element that stops one liquid until flow is triggered by a second liquid – was tested for different geometries and different solutions. Trigger valves with geometries up to 80-fold larger than cleanroom-fabricated ones were found to function reliably. We designed retention burst valves that encode sequential liquid delivery using capillary pressure differences encoded by systematically varied heights and widths. Using an electrical circuit analogue of the CC, we established design rules to ensure strictly sequential liquid delivery. CCs autonomously delivered eight liquids in a pre-determined sequence in <7 min. Taken together, our results demonstrate that 3D-printing lowers the bar for other researchers to access capillary microfluidic valves and CCs for autonomous liquid delivery with applications in diagnostics, research and education.

6 June 2017 in Analytical Chemistry
Verified
Journal Article
Open access
AOAyokunle Olanrewaju
Ayokunle Olanrewaju
ANAndy Ng
Andy Ng
PDPhilippe DeCorwin-Martin
Philippe DeCorwin-Martin
ARAlessandra Robillard
Alessandra Robillard
DJDavid Juncker
David Juncker
Urinary tract infections (UTI) are one of the most common bacterial infections and would greatly benefit from a rapid point-of-care diagnostic test. Although significant progress has been made in developing microfluidic systems for nucleic acid and whole bacteria immunoassay tests, their practical application is limited by complex protocols, bulky peripherals, and slow operation. Here we present a microfluidic capillaric circuit (CC) optimized for rapid and automated detection of bacteria in urine. Molds for CCs were constructed using previously established design rules, then 3D-printed and replicated into poly(dimethylsiloxane). CCs autonomously and sequentially performed all liquid delivery steps required for the assay. For efficient bacteria capture, on-the-spot packing of antibody-functionalized microbeads was completed in <20 s followed by autonomous sequential delivery of 100 μL of bacteria sample, biotinylated detection antibodies, fluorescent streptavidin conjugate, and wash buffer for a total volume ≈115 μL. The assay was completed in 105 CFU/mL) for UTI. The self-powered, peripheral-free CC presented here has potential for use in rapid point-of-care UTI screening.

1 November 2024 in ACS Omega
Verified
Journal Article
Open access
KLKelsey M. Leong
Kelsey M. Leong
ASAileen Y. Sun
Aileen Y. Sun
MQMindy L. Quach
Mindy L. Quach
CLCarrie H. Lin
Carrie H. Lin
CCCosette A. Craig
Cosette A. Craig
AOAyokunle Olanrewaju
Ayokunle Olanrewaju
Microfluidics offer user-friendly liquid handling for a range of biochemical applications. 3D printing microfluidics is rapid and cost-effective compared to conventional cleanroom fabrication. Typically, microfluidics are 3D printed using digital light projection (DLP) stereolithography (SLA), but many models in use are expensive (≥$10,000 USD), limiting widespread use. Recent liquid crystal display (LCD) technology advancements have provided inexpensive (<$500 USD) SLA 3D printers with sufficient pixel resolution for microfluidic applications. However, there are only a few demonstrations of microfluidic fabrication, limited validation of print fidelity, and no direct comparisons between LCD and DLP printers. We compared a 40 μm pixel DLP printer (∼$18,000 USD) with a 34.4 μm pixel LCD printer (<$380 USD). Consistent with prior work, we observed linear trends between designed and measured channel widths ≥4 pixels on both printers, so we calculated accuracy above this size threshold. Using a standard IPA-wash resin and optimized parameters for each printer, the average error between designed and measured widths was 2.11 ± 1.26% with the DLP printer and 15.4 ± 2.57% with the 34.4 μm LCD printer. Printing with optimized conditions for a low-cost water-wash resin designed for LCD-SLA printers resulted in an average error of 2.53 ± 0.94% with the 34.4 μm LCD printer and 5.35 ± 4.49% with a 22 μm LCD printer. We characterized additional parameters including surface roughness, channel perpendicularity, and light intensity uniformity, and as an application of LCD-printed devices, we demonstrated consistent flow rates in capillaric circuits for self-regulated and self-powered delivery of multiple liquids. LCD printers are an inexpensive alternative for fabricating microfluidics, with minimal differences in fidelity and accuracy compared with a 40X more expensive DLP printer.

6 April 2020 in ACS Sensors
Verified
Journal Article
Closed access
AOAyokunle Olanrewaju
Ayokunle Olanrewaju
BSBenjamin P. Sullivan
Benjamin P. Sullivan
JZJane Y. Zhang
Jane Y. Zhang
ABAndrew T. Bender
Andrew T. Bender
DSDerin Sevenler
Derin Sevenler
JPJonathan D. Posner
Jonathan D. Posner

20 December 2024 in Polymer Chemistry
Verified
Journal Article
Open access
PDF file
JVJ. Antonio Vazquez
J. Antonio Vazquez
XPXabier Lopez de Pariza
Xabier Lopez de Pariza
NBNathan Ballinger
Nathan Ballinger
NSNaroa Sadaba
Naroa Sadaba
ASAileen Y. Sun
Aileen Y. Sun
ANAlshakim Nelson
Alshakim Nelson
Photo-mediated additive manufacturing from liquid resins (vat photopolymerization) is a rapidly growing field that will enable a new generation of electronic devices, sensors, and soft robotics. Radical-based polymerization remains the standard for photo-curing resins during the printing process due to its fast polymerization kinetics and the range of available photoinitiators. Comparatively, there are fewer examples of non-radical chemical reactions for vat photopolymerization, despite the potential for expanding the range of functional materials and devices. Herein, we demonstrate ionic liquid resins for vat photopolymerization that utilize photo-base generators (PBGs) to catalyze thiol-Michael additions as the network forming reaction. The ionic liquid increased the rate of curing, while also introducing ionic conductivity to the printed structures. Among the PBGs explored, 2-(2-nitrophenyl)-propyloxycarbonyl tetramethylguanidine (NPPOC-TMG) was the most effective for the vat photopolymerization process wherein 250 μm features were successfully printed. Lastly, we compared the mechanical properties of the PBG catalyzed thiol-Michael network versus the radical polymerized network. Interestingly, the thiol-Michael network had an overall improvement in ductility compared to the radical initiated resin, since step-growth methodologies afford more defined networks than chain growth. These ionic liquid resins for thiol-Michael additions expand the chemistries available for vat photopolymerization and present opportunities for fabricating devices such as sensors.