Nora Renz

Dr. Nora Renz


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Clinical Microbiology and Infection
Verified
Journal Article
Closed access
ARA. Rakow
A. Rakow
CPC. Perka
C. Perka
ATA. Trampuz
A. Trampuz
NRNora Renz
Nora Renz

22 October 2019 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
Cheng LiCheng Li
Cheng Li
NRNora Renz
Nora Renz
Andrej TrampuzAndrej Trampuz
Andrej Trampuz
Cristina Ojeda-ThiesCristina Ojeda-Thies
Cristina Ojeda-Thies
Background: Misconceptions and errors in the management of periprosthetic joint infection (PJI) can compromise the treatment success. The goal of this paper is to systematically describe twenty common mistakes in the diagnosis and management of PJI, to help surgeons avoid these pitfalls.Materials and methods: Common diagnostic and treatment errors are described, analyzed and interpreted.Results: Diagnostic errors include the use of serum inflammatory biomarkers (such as C-reactive protein) to rule out PJI, incomplete evaluation of joint aspirate, and suboptimal microbiological procedures (such as using swabs or collection of insufficient number of periprosthetic samples). Further errors are missing possible sources of distant infection in hematogenous PJI or overreliance on suboptimal diagnostic criteria which can hinder or delay the diagnosis of PJI or mislabel infections as aseptic failure. Insufficient surgical treatment or inadequate antibiotic treatment are further reasons for treatment failure and emergence of antimicrobial resistance. Finally, wrong surgical indication, both underdebridement and overdebridement or failure to individualize treatment can jeopardize surgical results.Conclusion: Multidisciplinary teamwork with infectious disease specialists and microbiologists in collaboration with orthopedic surgeons have a synergistic effect on the management of PJI. An awareness of the possible pitfalls can improve diagnosis and treatment results.

1 February 2018 in Diagnostic Microbiology and Infectious Disease
Verified
Journal Article
Closed access
Christian MorgensternChristian Morgenstern
Christian Morgenstern
SCSabrina Cabric
Sabrina Cabric
CPCarsten Perka
Carsten Perka
ATAndrej Trampuz
Andrej Trampuz
NRNora Renz
Nora Renz

20 August 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NRNora Renz
Nora Renz
SMStasa Mudrovcic
Stasa Mudrovcic
CPCarsten Perka
Carsten Perka
ATAndrej Trampuz
Andrej Trampuz
The definition criteria and clinical characteristics of implant-associated infection (IAI) caused by Cutibacterium (formerly Propionibacterium) spp. are poorly known. We analyzed microbiologically proven Cutibacterium orthopedic IAI in a prospective cohort. Patients with periprosthetic joint infections (PJI) and fixation device–associated infections (FDAI) caused by Cutibacterium spp. were prospectively included. IAI was defined by significant growth of Cutibacterium spp. and presence of at least one non-microbiological criterion for infection. The McNemar’s chi-squared or binomial test was used to compare the performance of diagnostic tests. Of 121 patients with Cutibacterium IAI, 62 patients (51%) had PJI and 59 (49%) had FDAI. 109 infections (90%) were caused by C. acnes and 12 (10%) by C. avidum. The median time from implantation until diagnosis of infection was 15.7 months (interquartile range, 5–46.5 months). Clinical local signs were present in 30 patients (28%) and radiological implant loosening in 64 patients (63%). Culture sensitivity of sonication fluid was 84%, of peri-implant tissue 84% and of synovial or peri-implant fluid 56% after 14 days of incubation. Cutibacterium IAI was diagnosed late in the disease course and presented with subtle signs. Prolonged culture incubation and implant sonication improved the poor performance of conventional microbiological tests. Due to lack of reliable diagnostic tests, Cutibacterium remains difficult to detect making the diagnosis challenging.

3 November 2020 in Infection
Verified
Journal Article
Open access
PDF file
PSPhilipp Schulz
Philipp Schulz
CDConstantin E. Dlaska
Constantin E. Dlaska
CPCarsten Perka
Carsten Perka
ATAndrej Trampuz
Andrej Trampuz
NRNora Renz
Nora Renz
Purpose: We investigated the value of preoperative pathogen detection and evaluated its concordance with intraoperative cultures in patients with culture-positive periprosthetic joint infection (PJI). Methods: Culture-positive PJI episodes with available preoperative (synovial fluid) and intraoperative cultures (periprosthetic tissue, synovial or sonication fluid) were analyzed. The pathogen detection rate in preoperative and intraoperative cultures was compared using Fisher’s exact test and their concordance was calculated. Results: Among 167 included PJI episodes, 150 were monomicrobial with coagulase-negative staphylococci (n = 55, 37%), S. aureus (n = 34, 23%), and streptococci (n = 21, 14%) being the most common pathogens. Seventeen episodes (10%) were polymicrobial infections. The pathogen(s) grew in preoperative culture in 110 and in intraoperative cultures in 153 episodes (66% vs. 92%, p < 0.001). The pathogen detection rate was lower in preoperative compared to intraoperative cultures for low-virulent pathogens (40% vs. 94%, p < 0.001), polymicrobial infections (59% vs. 100%, p = 0.007), and in delayed and late PJI (63% vs. 94%, and 66% vs. 91%, respectively, p < 0.001). Full concordance of preoperative and intraoperative cultures was found in 87 episodes (52%). The pathogen was detected solely preoperatively in 14 episodes (8%) and solely intraoperatively in 57 cases (34%); an additional pathogen was found in 3 episodes (2%) preoperatively and in 6 episodes (4%) intraoperatively. Conclusion: The concordance of preoperative and intraoperative cultures was poor (52%). The sole or an additional pathogen was found exclusively in intraoperative cultures in 38% of PJI episodes, hence preoperative synovial fluid cultures are considered unreliable for pathogen detection in PJI.

5 October 2017 in Infection
Verified
Journal Article
Closed access
PDF file
NRNora Renz
Nora Renz
SFSusanne Feihl
Susanne Feihl
SCSabrina Cabric
Sabrina Cabric
ATAndrej Trampuz
Andrej Trampuz