Liang Qiao

Dr. Liang Qiao

School of Architecture, Harbin Institute of Technology

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
HJHong Jin
Hong Jin
LQLiang Qiao
Liang Qiao
PCPeng Cui
Peng Cui
In urban areas, local microclimate is influenced by architectural forms, which will in turn affect human comfort. Taking Daqing as an example, this article studies the microclimate of a university campus in the severe cold area in China. Based on the space features of the streets, we categorize the streets into three types: open type, semi-open type, and street-entry type. Through analysis, this article researches microclimates of the three kinds of streets, the influence of building heating on the surrounding thermal environment, the relationship between streets’ morphology features and microclimate and human comfort (physiological equivalent temperature, PET). By study and analysis, we have the following findings: for open-type streets, the average globe temperatures of streets with different orientations can reach 1.3 °C in winter because of the influence of sidewalk trees. For semi-open-type streets, streets temperature is under the influence of the locating directions of buildings. The maximum air temperature difference among streets with different building arrangements reaches 2.1 °C in winter. For street-entry-type streets, the height–width ratios and orientations of streets are related to the continuity degree of the street interfaces. The building interface acts as a heating element and affect the surrounding thermal environment by heat convection and heat radiation. Analysis demonstrates that heat convection has a more obvious effect on rising surrounding temperature than heat radiation. Buildings with higher heat radiation witness higher globe temperature. For street-entry-type streets and semi-open-type streets, the SVF (sky view factor) and L/C (plane opening rate) of streets are negatively correlated with temperature and PET, but positively correlated with wind speed. If the SVF increases 0.1, the air temperature will reduce 0.1 °C, the wind speed will increase 0.19 m/s, and the PET will reduce 0.7 °C.

28 November 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
LQLiang Qiao
Liang Qiao
LQLiang Qiao
Liang Qiao
In this study, we collected 927 cases of samples from students at the Harbin Institute of Technology, China and conducted a thermal comfort questionnaire survey on four outdoor exercise modes in winter. Additionally, we analyzed the thermal perception conditions of the campus population in winter, the association between exercise volume and TCV (Thermal Comfort Vote) and the correlation between PET (physiological equivalent temperature) and MTSV (Mean Thermal Sensation Vote). Furthermore, we identified different PET neutral temperatures under different exercise modes (skating 3 °C, running 6 °C, hiking 9 °C, standing 14 °C), the variability of different thermal comforts in the original residence and the trend of thermal comfort with outdoor activity time. Finally, we obtained the prediction model of thermal perception under different exercise modes, and it can used as a basis for assessing the cold outdoor thermal environment to provide some references for environmental designers.

5 November 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
LQLiang Qiao
Liang Qiao
XYXinling Yan
Xinling Yan
Irrational spatial configuration of campuses has contributed to changes in local microclimates, thus reducing human thermal comfort, particularly in severely cold regions of China. This paper sets out to establish correlation equations between campus spatial morphology indicators and Physiologically Equivalent Temperature (PET). Based on measured data from two campus sites, Geographic Information Systems (GIS) were utilized to analyze the characteristics of microclimate distribution and highly sensitive morphological parameters were screened. Regression analysis was conducted to determine the correlation between spatial morphology indicators and PET. During winter, open spaces were most correlated with Sky View Factor (SVF), with each 0.1 increase in SVF resulting in a 0.7 °C rise in PET. Enclosed spaces exhibited strong correlations with the Closure Ratio of Enclosure (Ce) and Surface Wall Area (SW), where every 10% increase in Ce led to a 0.46 °C increase in PET and every additional 1000 m2 of SW caused a 1 °C rise in PET. We finally quantified the impact of changes in spatial morphology indicators on human thermal comfort, with the aim to integrate campus planning with climatic design and improve the outdoor thermal environment of campuses.

19 December 2025 in Research Square
Verified
Preprint
Open access
PDF file
GHGuanjun Huang
Guanjun Huang
RWRui Wu
Rui Wu
LQLiang Qiao
Liang Qiao
High-resolution building extraction from remote sensing images plays a pivotal role in urban planning, disaster response, and land-use monitoring. However, the complex urban environment—characterized by dense building distributions, varied architectural styles, and blurred object boundaries—poses significant challenges for existing semantic segmentation models. To address these issues, we propose DE-Net, a novel semantic segmentation framework designed for precise building extraction from high-resolution unmanned aerial vehicle (UAV) imagery. DE-Net consists of three key components: a ConvNeXt-based feature backbone that captures hierarchical semantic features while preserving spatial detail; a Spatial Resolution Adaptive Reconstruction Module (SRARM) that dynamically decodes features based on predicted density maps, enabling tailored upsampling strategies for dense and sparse regions; and a Multi-Scale Edge-Aware Fusion Module (MS-EAM) that extracts edge attention from each encoder stage and fuses them to enhance boundary localization. Experiments on a high-resolution UAV dataset show that DE-Net outperforms other methods in IoU (86.78%), F1 score (92.91%), and boundary IoU, surpassing the second-best model, UPerNet, by 4.47% and 2.65%, achieving state-of-the-art performance.

26 June 2026 in The Journal of Supercomputing
Verified
Journal Article
Closed access
PDF file
GHGuanjun Huang
Guanjun Huang
RWRui Wu
Rui Wu
LQLiang Qiao
Liang Qiao