Data on the clinical outcomes comparing synthetic fluorocarbon polymer polytetrafluoroethylene- (PTFE, GraftMaster) and polyurethane- (Papyrus) covered stents (CSs) to seal coronary artery perforations (CAPs) are limited. We aimed to evaluate 30-day and 1-year clinical outcomes after PCI complicated by CAP and treated with CS. We assessed 106 consecutive patients with successful CAP sealing (122 CSs): GraftMaster (51 patients, 57 CSs) or Papyrus CS (55 patients, 65 CSs). The primary endpoint was the occurrence of major adverse cardiac events (MACE), defined as the composite of cardiac death, target lesion revascularisation (TLR), and myocardial infarction (MI). The mean age of subjects was 69 ± 9.6 years (53.8% males). No significant differences were identified between the GraftMaster and Papyrus groups at the 30-day follow-up for MACE, cardiac death, MI and stent thrombosis (ST), while significantly lower rate of TLR and TVR (p = 0.02) were confirmed in the Papyrus group. At one year, differences remained similar between stents for MACE, a trend towards a lower rate of TLR (p = 0.07), MI (p = 0.08), and ST (p = 0.08), and higher for cardiac death (p = 0.07) was observed in the Papyrus group. This real-life registry of CAP illustrated that the use of Papyrus CS is associated with lower rates of TLR and TVR at 30-day follow-up in comparison to the GraftMaster CSs and no significant differences between both assessed CS at one year of follow-up.
Background: Evidence concerning the efficacy of the embolic protection devices (EPDs) in saphenous vein graft (SVG) percutaneous coronary intervention (PCI) is sparse. The study was designed to compare major cardiovascular events of all-comer population of SVG PCI with and without EPDs at one year of follow-up. Methods and results: A multi-center registry comparing PCI with and without EPDs in consecutive patients undergoing PCI of SVG. The group comprised 792 patients, among which 266 (33.6%) had myocardial infarction (MI). The primary composite endpoint was major adverse cardiac and cerebrovascular event (MACCE) defined as death, MI, target vessel revascularization (TVR), and stroke assessed at one year. After propensity score analysis, there were no differences in MACCE (21.9% vs. 23.9%; HR 0.91, 95% CI 0.57–1.45, p = 0.681, respectively) nor in secondary endpoints of death, MI, TVR, target lesion revascularization (TLR) and stroke at one year in EPDs PCI group vs. no-EPDs PCI group. Similarly, there were no differences between groups in the study endpoints at 30 days follow-up. Conclusions: There were no clinical benefit for routine use of EPDs during SVG PCI in short and long-term follow-up. Further studies are warranted to explore the effect of individual types of EPDs on clinical outcomes.
Dual antiplatelet therapy (DAPT) is mandatory after percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation, but optimal DAPT duration remains a topic of intense discussion. The shorter regimen of DAPT might be especially beneficial for high-bleeding-risk (HBR) patients. Novel stent platforms have been designed with innovations that should facilitate vessel healing following stent implantation and enable short DAPT. This review aimed to summarize evidence of the neointimal coverage of short-term stents and their implications for DAPT duration. Results from histological and optical coherence tomography (OCT) studies confirm the significant role of uncovered struts after the implantation of a stent in patients presenting with late stent thrombosis. Several studies have shown favorable vessel healing at one month (with 83.2% of covered struts, on average) and three months following stent implantation (with 93.3% of covered struts, on average). Solely HBR patient trials have proven that one month of DAPT can be applicable and safe in this population. Three-month DAPT was tested in a more diverse population and remains effective and safe in comparison to a longer DAPT regimen. That evidence proves that short-term DAPT might be applicable, especially for HBR patients.
Background: Due to its high resolution, optical coherence tomography (OCT) is the most suitable modality for neointimal coverage assessments. Evaluation of stent healing seems crucial to accurately define their safety profile since delayed healing is connected with stent thrombosis. This study aimed to present an algorithm for automated quantitative analysis of stent strut coverage at the early stages of vessel healing in intravascular OCT. Methods: A set of 592 OCT frames from 24 patients one month following drug-eluting stent implantation was used to assess the algorithm’s effectiveness. Struts not covered on any side or covered but only on one side were categorized as uncovered. The algorithm consists of several key steps: preprocessing, vessel lumen segmentation, automatic strut detection, and measurement of neointimal thickness. Results: The proposed algorithm proved its efficiency in lumen and stent area estimation versus manual reference. It showed a high positive predictive value (PPV) (89.7%) and true positive rate (TPR) (91.4%) in detecting struts. A qualitative assessment for covered and uncovered struts was characterized by high TPR (99.1% and 80%, respectively, for uncovered and covered struts) and PPV (77.3% and 87%). Conclusions: The proposed algorithm demonstrated good agreement with manual measurements. Automating the stent coverage assessment might facilitate imaging analysis, which might be beneficial in experimental and clinical settings.