Gert Meijer

Prof. Dr. Gert Meijer

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
HGH. Ghaeminia
H. Ghaeminia
NGN.L. Gerlach
N.L. Gerlach
THTh.J.M. Hoppenreijs
Th.J.M. Hoppenreijs
MKM. Kicken
M. Kicken
JDJ.P. Dings
J.P. Dings
TMT.J. Maal
T.J. Maal

27 February 2016 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
HGH. Ghaeminia
H. Ghaeminia
THTh. J. M Hoppenreijs
Th. J. M Hoppenreijs
TXTong Xi
Tong Xi
JFJ. P. Fennis
J. P. Fennis
TMT. J Maal
T. J Maal
GMGert Meijer
Gert Meijer
Objectives The primary aim of the present study was to evaluate the effectiveness of postoperative irrigation of the socket with drinking tap water on inflammatory complications following lower third molar removal. Material and methods A multicenter randomized controlled trial was carried out from June 2013 to June 2014. In one arm of the study, patients were instructed to irrigate the tooth socket and surgical site with a Monoject® Curved 412 Tip Syringe (Tyco/healthcare-Kendall, Mansfield, MA, USA) with tap water. In a second arm of the study, the standard postoperative instructions did not include irrigation instructions. The incidences of alveolar osteitis and wound infection were recorded for each group and analyzed by the Fisher’s exact test. Results A total of 280 patients with 333 mandibular third molars were analyzed. According to the intention-to-treat (ITT) analysis, inflammatory complications occurred in 18 cases in the Monoject® group (11.4 %) compared to 34 cases (19.1 %) in the control group (p = 0.04). These complications were associated with significant worse outcomes regarding quality of life, pain, and trismus and caused significantly more missed days of work or study. Female gender, age >26, bone removal, deep impacted third molars, less experienced surgeons, and a high amount of debris at the surgical site were also identified as risk factors for developing inflammatory complications following lower third molar removal. Conclusion Irrigation of the surgical site with drinking tap water using a curved syringe following removal of third molars is effective in reducing the risk of inflammatory complications. Clinical relevance Water is a very accessible, cost-effective irrigant without side effects and the results from this study have proven that it can be used to reduce the risk of inflammatory complications and associated morbidity following lower third molar removal.

1 March 2020 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
Luc Van DoorneLuc Van Doorne
Luc Van Doorne
LKL. De Kock
L. De Kock
AMA. De Moor
A. De Moor
RSR. Shtino
R. Shtino
Ewald BronkhorstEwald Bronkhorst
Ewald Bronkhorst
HBHugo De Bruyn
Hugo De Bruyn

3 January 2022 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
PDF file
TSTristan Staas
Tristan Staas
EGEdith Groenendijk
Edith Groenendijk
EBEwald Bronkhorst
Ewald Bronkhorst
LVLuc Verhamme
Luc Verhamme
GRGerry Max Raghoebar
Gerry Max Raghoebar
GMGert Meijer
Gert Meijer
Background: Flapless immediate implant placement and provisionalization (FIIPP) in the aesthetic zone is still controversial. Especially, an initial buccal crest thickness (BCT) of ≤1 mm is thought to be disruptive for the final buccal crest stability jeopardizing the aesthetic outcome.Purpose: To radiographically assess the BCT and buccal crest height (BCH) after 1 year and to calculate the correlation between initial and final achieved BCT.Materials and Methods: The study was designed as a prospective study on FIIPP. Only patients were included in whom one maxillary incisor was considered as lost. In six centers, 100 consecutive patients received FIIPP. Implants were placed in a maximal palatal position of the socket, thereby creating a buccal space of at least 2 mm, which was subsequently filled with a bovine bone substitute. Files of preoperative (T0), peroperative (T1) and 1‐year postoperative (T3) cone beam computed tomogram (CBCT) scans were imported into the Maxillim™ software to analyze the changes in BCT‐BCH over time.Results: Preoperatively, 85% of the cases showed a BCT ≤1 mm, in 25% of the patients also a small buccal defect (≤5 mm) was present. Mean BCT at the level of the implant‐shoulder increased from 0.6 mm at baseline to 3.3 mm immediate postoperatively and compacted to 2.4 mm after 1 year. Mean BCH improved from 0.7 to 3.1 mm peroperatively, and resorbed to 1.7 mm after 1 year. The Pearson correlation of 0.38 between initial and final BCT was significant (p = 0.01) and therefore is valued as moderate. If only patients (75%) with an intact alveolus were included in the analysis, still a “moderate correlation” of 0.32 (p = 0.01) was calculated.Conclusions: A “moderate correlation” was shown for the hypothesis that “thinner preoperative BCT's deliver thinner BCT's” 1 year after performing FIIPP.

5 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JHJan Cornelis Maria van Hooft
Jan Cornelis Maria van Hooft
GKGuido Kielenstijn
Guido Kielenstijn
JLJeroen Liebregts
Jeroen Liebregts
FBF. Baan
F. Baan
GMGert Meijer
Gert Meijer
LVLuc Verhamme
Luc Verhamme
(1) Background: For years, Cone-Beam Computed Tomography’s (CBCT) have been the golden standard to evaluate implant placement accuracy. By validating Intraoral Scans (IOS) as an alternative to determine implant placement accuracy, a second CBCT could be avoided. (2) Methods: Using dynamic guided implant surgery, 23 implants were placed in 16 partially edentate patients. Preoperatively, both CBCT and IOS (Trios® 3) were obtained and subsequently imported into DTX Studio™ planning software to determine the ideal implant location. A CBCT scan and an IOS including scan abutments were acquired immediately after placement. Both postoperative CBCT and postoperative IOS were used to compare the achieved implant position with the planned implant position and were projected and analyzed using the Implant Position Orthogonal Projection (IPOP) method. (3) Results: Mean differences between the CBCT and IOS methods on the mesio–distal plane were 0.09 mm (p = 0.419) at the tip, 0.01 mm (p = 0.910) at the shoulder, −0.55° (p = 0.273) in angulation, and 0.2 mm (p = 0.280) in implant depth. Mean differences between both methods on the bucco-lingual/bucco-palatal plane were 0.25 mm (p = 0.000) at the tip, 0.12 mm (p = 0.011) at the shoulder, −0.81° (p = 0.002) in angulation, and 0.17 mm (p = 0.372) in implant depth. A statistical analysis was performed using a paired t-test. All mesiodistal deviations between the two methods showed no significant differences (p > 0.05). Buccolingual/buccopalatal deviations showed no significant difference in implant depth deviation. However, significant differences were found at the tip, shoulder, and angulation (p < 0.05). These values are of minimal clinical significance. (4) Conclusions: This study supports the hypothesis that a postoperative IOS is a valid alternative for determining implant placement accuracy.

15 July 2021 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
PDF file
TWThomas Van de Winkel
Thomas Van de Winkel
LHLaura Heijens
Laura Heijens
SLStefan Listl
Stefan Listl
GMGert Meijer
Gert Meijer
Background: Implant‐supported overdentures (IODs) have been reported to increase patients' oral health‐related quality of life (OHRQoL) in comparison with conventional dentures (CDs); however, the conclusiveness of evidence on the clinical effectiveness and value for money of IODs versus CDs remains unclear.Purpose: To review how the added value of IODs is demonstrated in the literature.Materials and methods: MEDLINE, EMBASE, and the Cochrane Database were searched for randomized control trials, controlled clinical trials, and prospective cohort studies containing evaluations of the economic and health benefits and costs of IODs. Information about the clinical effectiveness, such as magnitude of bite forces or chewing efficacy, OHRQoL, costs, and cost‐effectiveness of IODs, was extracted.Results: A total of 17 articles were included, reporting 15 economic evaluations: 11 cost‐utility analyses (CUAs), 2 of which were combined with a cost‐effectiveness analysis (CEA), and 2 cost–benefit analyses (CBAs). Seven CUAs used the Oral Health Impact Profile (OHIP) questionnaire while four used satisfaction questionnaires to assess the OHRQoL. One study applied quality‐adjusted prosthesis years (QAPYs) for this purpose. The CBAs expressed both the beneficial outcome and the costs of the IOD in monetary terms. The included studies employed a large variety of economic evaluation methods, which limited cross‐study comparability.Conclusions: On the basis of existing economic evaluations, IODs have frequently been suggested to be a cost‐efficient treatment alternative to CDs; however, the comparability between the various economic evaluation studies was limited due to the different outcome measures used. In addition, it remains unclear whether the additional health benefits of IODs outweigh the higher costs. This is largely dependent on the decision maker's valuation of oral health outcomes. Future research is encouraged to further elucidate patient willingness to pay for IODs and the societal return on investing in IODs more generally.