Ali T Alouani

Prof. Ali T Alouani

Tennessee Technological University, Cookeville, Tennessee, USA
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2025 in Drones
Verified
Journal Article
Open access
PDF file
CEChijioke C. Ekechi
Chijioke C. Ekechi
Tarek ElfoulyTarek Elfouly
Tarek Elfouly
Ali T AlouaniAli T Alouani
Ali T Alouani
TKTamer Khattab
Tamer Khattab
Unmanned Aerial Vehicles (UAVs) have become increasingly prevalent in both governmental and civilian applications, offering significant reductions in operational costs by minimizing human involvement. There is a growing demand for autonomous, scalable, and intelligent coordination strategies in complex aerial missions involving multiple Unmanned Aerial Vehicles (UAVs). Traditional control techniques often fall short in dynamic, uncertain, or large-scale environments where decentralized decision-making and inter-agent cooperation are crucial. A potentially effective technique used for UAV fleet operation is Multi-Agent Reinforcement Learning (MARL). MARL offers a powerful framework for addressing these challenges by enabling UAVs to learn optimal behaviors through interaction with the environment and each other. Despite significant progress, the field remains fragmented, with a wide variety of algorithms, architectures, and evaluation metrics spread across domains. This survey aims to systematically review and categorize state-of-the-art MARL approaches applied to UAV control, identify prevailing trends and research gaps, and provide a structured foundation for future advancements in cooperative aerial robotics. The advantages and limitations of these techniques are discussed along with suggestions for further research to improve the effectiveness of MARL application to UAV fleet management.

3 October 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
Ali T AlouaniAli T Alouani
Ali T Alouani
Tarek ElfoulyTarek Elfouly
Tarek Elfouly
Traumatic brain injury (TBI) can produce temporary biochemical imbalance due to leaks through cell membranes or disruption of the axoplasmic flow due to the misalignment of intracellular neurofilaments. If untreated, TBI can lead to Alzheimer’s, Parkinson’s, or total disability. Mild TBI (mTBI) accounts for about about 90 percent of all TBI cases. The detection of TBI as soon as it happens is crucial for successful treatment management. Neuroimaging-based tests provide only a structural and functional mapping of the brain with poor temporal resolution. Such tests may not detect mTBI. On the other hand, the electroencephalogram (EEG) provides good spatial resolution and excellent temporal resolution of the brain activities beside its portability and low cost. The objective of this paper is to provide clinicians and scientists with a one-stop source of information to quickly learn about the different technologies used for TBI detection, their advantages and limitations. Our research led us to conclude that even though EEG-based TBI detection is potentially a powerful technology, it is currently not able to detect the presence of a mTBI with high confidence. The focus of the paper is to review existing approaches and provide the reason for the unsuccessful state of EEG-based detection of mTBI.

29 August 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Tarek ElfoulyTarek Elfouly
Tarek Elfouly
Ali T AlouaniAli T Alouani
Ali T Alouani
Wearable computing is evolving from a passive data collection paradigm into an active, precision-guided health orchestration system. This survey synthesizes developments across sensing modalities, wireless protocols, computational frameworks, and AI-driven analytics that collectively define the state of the art in mental and physical health monitoring. A narrative review methodology is used to map the landscape of hardware innovations—including microfluidic sweat sensing, smart textiles, and textile-embedded biosensing ecosystems—alongside advances in on-device AI acceleration, context-aware multimodal fusion, and privacy-preserving learning frameworks. The analysis highlights a shift toward multiplexed biochemical sensing for real-time metabolic profiling, neuromorphic and analog AI processors for ultra–low-power analytics, and closed-loop therapeutic systems capable of adapting interventions dynamically to both physiological and psychological states. These trends are examined in the context of emerging clinical and consumer use cases, with a focus on scalability, personalization, and data security. By grounding these insights in current research trajectories, this work positions wearable computing as a cornerstone of preventive, personalized, and participatory healthcare. Addressing identified technical and ethical challenges will be essential for the next generation of systems to become trusted, equitable, and clinically indispensable tools.

1 November 2020 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
BEBrandon S. England
Brandon S. England
Ali T AlouaniAli T Alouani
Ali T Alouani

18 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Tarek ElfoulyTarek Elfouly
Tarek Elfouly
Ali T AlouaniAli T Alouani
Ali T Alouani
Heart diseases remain one of the leading causes of morbidity and mortality worldwide, necessitating innovative diagnostic methods for early detection and intervention. An electrocardiogram (ECG) is a well-known technique for the preliminary diagnosis of heart conditions. However, it can not be used for continuous monitoring due to skin irritation. It is well known that every body organ generates a magnetic field, and the heart generates peak amplitudes of about 10 to 100 pT (measured at a distance of about 3 cm above the chest). This poses challenges to capturing such signals. This paper reviews the different techniques used to capture the heart’s magnetic signals along with their limitations. In addition, this paper provides a comprehensive review of the different approaches that use the heart-generated magnetic field to diagnose several heart diseases. This research reveals two aspects. First, as a noninvasive tool, the use of the heart’s magnetic field signal can lead to more sensitive advanced heart disease diagnosis tools, especially when continuous monitoring is possible and affordable. Second, its current use is limited due to the lack of accurate, affordable, and portable sensing technology.

5 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Mohammad Mahbubur Rahman Khan MamunMohammad Mahbubur Rahman Khan Mamun
Mohammad Mahbubur Rahman Khan Mamun
Ali T AlouaniAli T Alouani
Ali T Alouani
The cuffless blood pressure (BP) measurement allows for frequent measurement without discomfort to the patient compared to the cuff inflation measurement. With the availability of a large dataset containing physiological waveforms, now it is possible to use them through different learning algorithms to produce a relationship with changes in BP. In this paper, a novel cuffless noninvasive blood pressure measurement technique has been proposed using optimized features from electrocardiogram and photoplethysmography based on multivariate symmetric uncertainty (MSU). The technique is an improvement over other contemporary methods due to the inclusion of feature optimization depending on both linear and nonlinear relationships with the change of blood pressure. MSU has been used as a selection criterion with algorithms such as the fast correlation and ReliefF algorithms followed by the penalty-based regression technique to make sure the features have maximum relevance as well as minimum redundancy. The result from the technique was compared with the performance of similar techniques using the MIMIC-II dataset. After training and testing, the root mean square error (RMSE) comes as 5.28 mmHg for systolic BP and 5.98 mmHg for diastolic BP. In addition, in terms of mean absolute error, the result improved to 4.27 mmHg for SBP and 5.01 for DBP compared to recent cuffless BP measurement techniques which have used substantially large datasets and feature optimization. According to the British Hypertension Society Standard (BHS), our proposed technique achieved at least grade B in all cumulative criteria for cuffless BP measurement.