The electroreduction of CO2 is one of the most investigated reactions and involves testing a large number and variety of catalysts. The majority of experimental electrocatalysis studies use conventional one-sample-at-a-time methods without providing spatially resolved catalytic activity information. Herein, we present the application of scanning electrochemical microscopy (SECM) for simultaneous screening of different catalysts forming an array. We demonstrate the potential of this method for electrocatalytic assessment of an array consisting of three Sn/SnOx catalysts for CO2 reduction to formate (CO2RF). Simultaneous SECM scans with fast scan (1 V s−1) cyclic voltammetry detection of products (HCOO−, CO and H2) at the Pt ultramicroelectrode tip were performed. We were able to consistently distinguish the electrocatalytic activities of the three compositionally and morphologically different Sn/SnOx catalysts. Further development of this technique for larger catalyst arrays and matrices coupled with machine learning based algorithms could greatly accelerate the CO2 electroreduction catalyst discovery.
The barrier performance of organic coatings is a direct function of mass transport and long-term stability of the polymeric structure. A predictive assessment of the protective coating cannot be conducted a priori of degradation effects on transport. Epoxy-based powder coatings are an attractive class of coatings for pipelines and other structures because application processing times are low and residual stresses between polymer layers are reduced. However, water ingress into the polymeric network of these coatings is of particular interest due to associated competitive sorption and plasticization effects. This review examines common analytical techniques for identifying parameters involved in transport in wet environments and underscores the gaps in the literature for the evaluation of the long-term performance of such coating systems. Studies have shown that the extent of polymer hydration has a major impact on gas and ion permeability/selectivity. Thus, transport analyses based only on micropore filling (i.e., adsorption) by water molecules are inadequate. Combinatorial entropy of the glassy epoxy and water vapor mixture not only affects the mechanism of membrane plasticization, but also changes the sorption kinetics of gas permeation and causes a partial gas immobility in the system. However, diffusivity, defined as the product of a kinetic mobility parameter and a concentration-dependent thermodynamic parameter, can eventually become favorable for gas transport at elevated temperatures, meaning that increasing gas pressure can decrease selectivity of the membrane for gas permeation. On the other hand, reverse osmosis membranes have shown that salt permeation is sensitive to, among other variables, water content in the polymer and a fundamental attribute in ionic diffusion is the effective size of hydrated ions. In addition, external electron sources—e.g., cathodic protection potentials for pipeline structures—can alter the kinetics of this transport as the tendency of ions to dissociate increases due to electrostatic forces. Focusing primarily on epoxy-based powder coatings, this review demonstrates that service parameters such as humidity, temperature, and concentration of aggressive species can dynamically develop different transport mechanisms, each at the expense of others. Although multilayered coating systems decrease moisture ingress and the consequences of environmental exposure, this survey shows that demands for extreme operating conditions can pose new challenges for coating materials and sparse data on transport properties would limit analysis of the remaining life of the system. This knowledge gap impedes the prediction of the likelihood of coating and, consequently, infrastructure failures.
5 January 2022 in ACS Applied Materials & Interfaces
Mg and its alloys are promising biodegradable materials for orthopedic implants and cardiovascular stents. The first interactions of protein molecules with Mg alloy surfaces have a substantial impact on their biocompatibility and biodegradation. We investigate the early-stage electrochemical, chemical, morphological, and electrical surface potential changes of alloy WE43 in either 154 mM NaCl or Hanks' simulated physiological solutions in the absence or presence of bovine serum albumin (BSA) protein. WE43 had the lowest electrochemical current noise (ECN) fluctuations, the highest noise resistance (Zn = 1774 Ω·cm2), and the highest total impedance (|Z| = 332 Ω·cm2) when immersed for 30 min in Hanks' solution. The highest ECN, lowest Zn (1430 Ω·cm2), and |Z| (49 Ω·cm2) were observed in the NaCl solution. In the solutions containing BSA, a unique dual-mode biodegradation was observed. Adding BSA to a NaCl solution increased |Z| from 49 to 97 Ω·cm2 and decreased the ECN signal of the alloy, i.e., the BSA inhibited corrosion. On the other hand, the presence of BSA in Hanks' solution increased the rate of biodegradation by decreasing both Zn and |Z| while increasing ECN. Finally, using scanning Kelvin probe force microscopy (SKPFM), we observed an adsorbed nanolayer of BSA with aggregated and fibrillar morphology only in Hanks' solution, where the electrical surface potential was 52 mV lower than that of the Mg oxide layer.