Dry eye disease is a common ocular condition affecting millions of people worldwide. Artificial tears are the first line therapy for the management of dry eye disease. Artificial tear formulations contain a variety of active ingredients, biologically active excipients, and preservatives. Many of these formulations are also available as preservative-free. This study was conducted to inspect artificial tear formulations currently marketed in the United States for their active ingredients, biologically relevant excipients, and preservatives. The marketed artificial tears were examined at various US retail pharmacy chains and using the manufacturers’ website to compile information about active ingredients, inactive ingredients, and preservatives. The currently marketed artificial tears can be grouped into four categories based on their active ingredients. The artificial tears also contain biologically active chemicals listed as inactive ingredients, which have osmoprotectant, humectant, and tear film lipid layer or mucous layer mimicking properties. Most artificial tears contain vanishing type preservatives such as purite or sodium perborate and safer quaternary compound polyquaternium-1. The majority of these artificial tear formulations are also available as preservative-free single dose unit. The study provides a formulary of artificial tears based on active ingredients, biologically active excipients, and the preservative-free option. The formulary should assist healthcare providers in making a stepwise and rational selection of appropriate artificial tears for patients suffering from dry eye disease.
Dry eye disease is among the most prevalent diseases affecting the ocular surface. Artificial tears remain the cornerstone therapy for its management. There are currently a wide variety of marketed artificial tears available to choose from. These artificial tears differ significantly in their composition and formulation. This article reviews the physicochemical and biological properties of artificial tear components and how these characteristics determine their use and efficacy in the management of dry eye. Furthermore, this article also discusses the various formulations of artificial tears such as macro and nanoemulsion and the type of preservatives present in them.
1 November 2023 in Investigative Ophthalmology & Visual Science
Purpose: The metabolic alterations due to chronic hyperglycemia are well-known to cause diabetes-associated complications. Short-term hyperglycemia has also been shown to cause many acute changes, including hemodynamic alterations and osmotic, oxidative, and inflammatory stress. The present study was designed to investigate whether diabetes-associated hyperglycemia can cause rapid-onset detrimental effects on the tear film, goblet cells, and glycocalyx and can lead to activation of an inflammatory cascade or cellular stress response in the cornea. Methods: Mouse models of type 1 and type 2 diabetes were used. Tear film volume, goblet cell number, and corneal glycocalyx area were measured on days 7, 14, and 28 after the onset of hyperglycemia. Transcriptome analysis was performed to quantify changes in 248 transcripts of genes involved in inflammatory, apoptotic, and stress response pathways. Results: Our data demonstrate that type 1 and type 2 diabetes-associated hyperglycemia caused a significant decrease in the tear film volume, goblet cell number, and corneal glycocalyx area. The decrease in tear film and goblet cell number was noted as early as 7 days after onset of hyperglycemia. The severity of ocular surface injury was significantly more in type 1 compared to type 2 diabetes. Diabetes mellitus also caused an increase in transcripts of genes involved in the inflammatory, apoptotic, and cellular stress response pathways. Conclusions: The results of the present study demonstrate that diabetes-associated hyperglycemia causes rapid-onset damage to the ocular surface. Thus, short-term hyperglycemia in patients with diabetes mellitus may also play an important role in causing ocular surface injury and dry eye.
1 November 2019 in Investigative Ophthalmology & Visual Science
Purpose: The present study was designed to investigate the role of ocular surface glycocalyx and mucins in graft versus host disease (GVHD)-associated dry eye. The ameliorative effect of topical rebamipide, a mucin secretagogue, on GVHD-associated dry eye was also tested. Methods: A mouse model of allogeneic transplantation was used to induce ocular GVHD with C57BL/6 as donors and B6D2F1 as recipient mice. Phenol red thread method and fluorescein staining was used to quantify tear secretion and corneal keratopathy. At 8 weeks after the allogeneic transplantation, corneas were harvested to perform glycocalyx staining and confocal microscopy. Goblet cell staining was performed using periodic acid Schiff's staining. Corneal and tear film levels of Mucin 1, 4, 16, 19, and 5AC were quantified using ELISA and real-time PCR. Rebamipide was applied topically twice daily to mice eyes. Results: Allogeneic transplantation resulted in ocular GVHD-associated dry eye characterized by a significant decrease in tear film volume and the onset of corneal keratopathy. Ocular GVHD caused a significant decrease in the area and thickness of corneal glycocalyx. A significant decrease in the goblet cells was also noted. A significant decrease in mucin 4 and 5AC levels was also observed. Topical treatment with rebamipide partially attenuated ocular GVHD-mediated decrease in tear film volume and significantly reduced the severity of corneal keratopathy. Conclusions: Ocular GVHD has detrimental impact on ocular surface glycocalyx and mucins. Rebamipide, a mucin secretagogue, partially prevents ocular GVHD-associated decrease in tear film and reduces the severity of corneal keratopathy.
1 September 2020 in Investigative Ophthalmology & Visual Science
Purpose: Patients with diabetes mellitus are reported to have ocular surface defects, impaired ocular surface barrier function, and a higher incidence of corneal and conjunctival infections. Tight junctions are critical for ocular surface barrier function. The present study was designed to investigate the effect of high glucose exposure on human corneal and conjunctival epithelial cell barrier function and tight junction proteins. Methods: Human corneal and conjunctival epithelial cells were exposed to 15 mM and 30 mM glucose for 24 and 72 hours. The barrier function was measured using transepithelial electrical resistance (TEER). The cell migration was quantified using scratch assay. The cells were harvested for protein extraction and mRNA isolation. Gene and protein expression of claudins, zonula occludens (ZOs), and occludin was quantified using real-time PCR and Western blot. Results: Glucose caused a significant decrease in TEER after 72 hours of exposure in both corneal and conjunctival epithelial cells. Glucose did not cause any notable change in migration of either corneal or conjunctival epithelial cells. Glucose exposure did not cause any notable change in protein expression of claudin-1, ZO-1, ZO-2, ZO-3, or occludin. On the other hand, 15 mM glucose caused an increase in gene expression of claudin-1, claudin-3, ZO-2, ZO-3, and occludin, a likely response to osmotic stress since 15 mM mannitol also caused consistently similar increase in gene expression of these proteins. Conclusions: High glucose exposure causes impairment of corneal and conjunctival epithelial cell barrier function, but this detrimental effect is not caused by a decrease in expression of tight junction proteins: claudin-1, ZO-1, ZO-2, ZO-3, and occludin.