The assessment of liver percentage fat fraction (%FF) using proton density fat fraction sequences is becoming increasingly accessible. Previous studies have tended to use multiple small ROIs that focus on Couinaud segments. In an effort to simplify day-to-day analysis, this study assesses the impact of using larger, elliptical ROIs focused on a single hepatic lobe. Additionally, we assess the impact of sampling fewer transhepatic slices when measuring %FF. Retrospective analysis of prospectively obtained images from 34 volunteers using an IDEAL IQ sequence. Two observers independently measured %FF using three different protocols: freehand whole-liver ROI (fh-ROI), elliptical-ROI on the right lobe (rt-ROI) and elliptical-ROI on the left lobe (lt-ROI). Inter-observer reliability for all measurements techniques was ‘excellent’ (Spearman’s rank correlation coefficients 0.81–0.98). There was a significant difference (Paired Wilcoxon Test: p < 0.001) between the median %FF obtained using fh-ROI when compared to the rt-ROI method, the maximum mean difference between the two techniques was 2.79% (95% CI). For all sampling methods a Kruskall-Wallis analysis demonstrated no significant difference in mean %FF when the number of slices sampled was reduced from 11 to 1. The mean coefficient of variance increased when more slices were sampled (3 slices = 0.1, 11 slices = 0.17, p < 0.001). Simplified ROIs focused on one hepatic lobe provide %FF measurements that are unlikely to be sufficiently accurate for use in clinical practice. Freehand whole-liver ROIs should be used in preference. A single freehand ROI measurement taken at the level of the hepatic hilum yields a %FF that is representative of the mean whole liver % FF. Multiple slices are needed to measure heterogeneity.
Purpose This study aims to investigate the role of diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) in combination for the detection of prostate cancer, specifically assessing the role of high b-values (> 1000 s/mm2), with a systematic review and meta-analysis of the existing published data. Methods The electronic databases MEDLINE, EMBASE, and OpenSIGLE were searched between inception and September 1, 2017. Eligible studies were those that reported the sensitivity and specificity of DWI and T2WI for the diagnosis of prostate cancer by visual assessment using a histopathologic reference standard. The QUADAS-2 critical appraisal tool was used to assess the quality of included studies. A meta-analysis with pooling of sensitivity, specificity, likelihood, and diagnostic odds ratios was undertaken, and a summary receiver-operating characteristics (sROC) curve was constructed. Predetermined subgroup analysis was also performed. Results Thirty-three studies were included in the final analysis, evaluating 2949 patients. The pooled sensitivity and specificity were 0.69 (95% CI 0.68–0.69) and 0.84 (95% CI 0.83–0.85), respectively, and the sROC AUC was 0.84 (95% CI 0.81–0.87). Subgroup analysis showed significantly better sensitivity with high b-values (> 1000 s/mm2). There was high statistical heterogeneity between studies. Conclusion The diagnostic accuracy of combined DWI and T2WI is good with high b-values (> 1000 s/mm2) seeming to improve overall sensitivity while maintaining specificity. However, further large-scale studies specifically looking at b-value choice are required before a categorical recommendation can be made.
The manual delineation of region of interest (RoI) in 3D magnetic resonance imaging (MRI) of the prostate is time-consuming and subjective. Correct identification of prostate tissue is helpful to define a precise RoI to be used in CAD systems in clinical practice during diagnostic imaging, radiotherapy and monitoring the progress of disease. Conditional GAN (cGAN), cycleGAN and U-Net models and their performances were studied for the detection and segmentation of prostate tissue in 3D multi-parametric MRI scans. These models were trained and evaluated on MRI data from 40 patients with biopsy-proven prostate cancer. Due to the limited amount of available training data, three augmentation schemes were proposed to artificially increase the training samples. These models were tested on a clinical dataset annotated for this study and on a public dataset (PROMISE12). The cGAN model outperformed the U-Net and cycleGAN predictions owing to the inclusion of paired image supervision. Based on our quantitative results, cGAN gained a Dice score of 0.78 and 0.75 on the private and the PROMISE12 public datasets, respectively.
Magnetic resonance angiography (MRA) has been increasingly used to assess peripheral arterial disease over the past decade as an alternative to conventional catheter angiography (digital subtraction angiography (DSA)), which has been the gold standard.