Andreas Hierlemann

Prof. Dr. Andreas Hierlemann

ETH Zurich, Zürich, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Cell
Verified
Journal Article
Open access
CCCameron S. Cowan
Cameron S. Cowan
MRMagdalena Renner
Magdalena Renner
MGMartina De Gennaro
Martina De Gennaro
BGBrigitte Gross-Scherf
Brigitte Gross-Scherf
DGDavid Goldblum
David Goldblum
BRBotond Roska
Botond Roska
Human organoids recapitulating the cell-type diversity and function of their target organ are valuable for basic and translational research. We developed light-sensitive human retinal organoids with multiple nuclear and synaptic layers and functional synapses. We sequenced the RNA of 285,441 single cells from these organoids at seven developmental time points and from the periphery, fovea, pigment epithelium and choroid of light-responsive adult human retinas, and performed histochemistry. Cell types in organoids matured in vitro to a stable “developed” state at a rate similar to human retina development in vivo. Transcriptomes of organoid cell types converged toward the transcriptomes of adult peripheral retinal cell types. Expression of disease-associated genes was cell-type-specific in adult retina, and cell-type specificity was retained in organoids. We implicate unexpected cell types in diseases such as macular degeneration. This resource identifies cellular targets for studying disease mechanisms in organoids and for targeted repair in human retinas.

13 June 2005 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WFW. Franks
W. Franks
ISI. Schenker
I. Schenker
PSP. Schmutz
P. Schmutz
AHAndreas Hierlemann
Andreas Hierlemann
A low electrode-electrolyte impedance interface is critical in the design of electrodes for biomedical applications. To design low-impedance interfaces a complete understanding of the physical processes contributing to the impedance is required. In this work a model describing these physical processes is validated and extended to quantify the effect of organic coatings and incubation time. Electrochemical impedance spectroscopy has been used to electrically characterize the interface for various electrode materials: platinum, platinum black, and titanium nitride; and varying electrode sizes: 1 cm/sup 2/, and 900 /spl mu/m/sup 2/. An equivalent circuit model comprising an interface capacitance, shunted by a charge transfer resistance, in series with the solution resistance has been fitted to the experimental results. Theoretical equations have been used to calculate the interface capacitance impedance and the solution resistance, yielding results that correspond well with the fitted parameter values, thereby confirming the validity of the equations. The effect of incubation time, and two organic cell-adhesion promoting coatings, poly-L-lysine and laminin, on the interface impedance has been quantified using the model. This demonstrates the benefits of using this model in developing a better understanding of the physical processes occurring at the interface in more complex, biomedically relevant situations.

1 November 2001 in Nature
Verified
Journal Article
Closed access
CHC. Hagleitner
C. Hagleitner
AHAndreas Hierlemann
Andreas Hierlemann
DLD. Lange
D. Lange
AKA. Kummer
A. Kummer
NKN. Kerness
N. Kerness
HBH. Baltes
H. Baltes

17 January 2008 in Chemical Reviews
Verified
Journal Article
Closed access
AHAndreas Hierlemann
Andreas Hierlemann
RGRicardo Gutierrez-Osuna
Ricardo Gutierrez-Osuna

7 May 2015 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JMJan Müller
Jan Müller
MBMarco Ballini
Marco Ballini
PLPaolo Livi
Paolo Livi
YCYihui Chen
Yihui Chen
MRMilos Radivojevic
Milos Radivojevic
AHAndreas Hierlemann
Andreas Hierlemann
Studies on information processing and learning properties of neuronal networks would benefit from simultaneous and parallel access to the activity of a large fraction of all neurons in such networks. Here, we present a CMOS-based device, capable of simultaneously recording the electrical activity of over a thousand cells in in vitro neuronal networks. The device provides sufficiently high spatiotemporal resolution to enable, at the same time, access to neuronal preparations on subcellular, cellular, and network level. The key feature is a rapidly reconfigurable array of 26 400 microelectrodes arranged at low pitch (17.5 μm) within a large overall sensing area (3.85 × 2.10 mm2). An arbitrary subset of the electrodes can be simultaneously connected to 1024 low-noise readout channels as well as 32 stimulation units. Each electrode or electrode subset can be used to electrically stimulate or record the signals of virtually any neuron on the array. We demonstrate the applicability and potential of this device for various different experimental paradigms: large-scale recordings from whole networks of neurons as well as investigations of axonal properties of individual neurons.

30 June 2014 in Nature Communications
Verified
Journal Article
Closed access
PDF file
OFOlivier Frey
Olivier Frey
PMPatrick M. Misun
Patrick M. Misun
DFDavid A. Fluri
David A. Fluri
Jan G HengstlerJan G Hengstler
Jan G Hengstler
AHAndreas Hierlemann
Andreas Hierlemann