Objectives: The feasibility of providing prolonged and controlled release of the experimental non-nucleoside reverse transcriptase inhibitor TMC120 from a silicone vaginal ring in quantities sufficient to maintain a vaginal concentration offering protection against heterosexual HIV transmission was investigated. Methods: Core-type, silicone elastomer vaginal rings containing TMC120 were manufactured, and in vitro release studies performed under sink conditions. The experimental release data, as determined by HPLC, were correlated with estimates of vaginal TMC120 concentrations required to inhibit HIV replication. Results: Continuous, zero-order release of TMC120 from core-type vaginal rings was observed in vitro over a 71 day period, equivalent to 136 μg/day. The release rate is predicted to maintain vaginal concentrations of the antiretroviral in the range of several orders of magnitude in excess of reported HIV inhibitory concentration values. Conclusions: Continuous and prolonged zero-order release of TMC120 from a silicone vaginal ring device at quantities predicted to prevent HIV infection was observed.
1 August 2009 in JAIDS Journal of Acquired Immune Deficiency Syndromes
Vaginal microbicides for the prevention of HIV transmission may be an important option for protecting women from infection. Incorporation of dapivirine, a lead candidate nonnucleoside reverse transcriptase inhibitor, into intravaginal rings (IVRs) for sustained mucosal delivery may increase microbicide product adherence and efficacy compared with conventional vaginal formulations. Twenty-four healthy HIV-negative women 18-35 years of age were randomly assigned (1:1:1) to dapivirine matrix IVR, dapivirine reservoir IVR, or placebo IVR. Dapivirine concentrations were measured in plasma and vaginal fluid samples collected at sequential time points over the 33-day study period (28 days of IVR use, 5 days of follow-up). Safety was assessed by pelvic/colposcopic examinations, clinical laboratory tests, and adverse events. Both IVR types were safe and well tolerated with similar adverse events observed in the placebo and dapivirine groups. Dapivirine from both IVR types was successfully distributed throughout the lower genital tract at concentrations over 4 logs greater than the EC50 against wild-type HIV-1 (LAI) in MT4 cells. Maximum concentration (C max) and area under the concentration-time curve (AUC) values were significantly higher with the matrix than reservoir IVR. Mean plasma concentrations of dapivirine were <2 ng/mL. These findings suggest that IVR delivery of microbicides is a viable option meriting further study.
Vaginal rings (VRs) are flexible, torus-shaped, polymeric devices designed to sustain delivery of pharmaceutical drugs to the vagina for clinical benefit. Following first report in a 1970 patent application, several steroid-releasing VR products have since been marketed for use in hormone replacement therapy and contraception. Since 2002, there has been growing interest in the use of VR technology for delivery of drugs that can reduce the risk of sexual acquisition of human immunodeficiency virus type 1 (HIV-1), the causative agent of acquired immunodeficiency syndrome (AIDS). Although no vaginally-administered product has yet been approved for HIV reduction/prevention, extensive research efforts are continuing and a number of VR devices offering sustained release of so-called 'HIV microbicide' compounds are currently being evaluated in late-stage clinical studies. This review article provides an overview of the published scientific literature within this important field of research, focusing primarily on articles published within peer-reviewed journal publications. Many important aspects of microbicide-releasing VR technology are discussed, with a particular emphasis on the technological, manufacturing and clinical challenges that have emerged in recent years.
Dissolving polymeric microneedle arrays formulated to contain recombinant CN54 HIVgp140 and the TLR4 agonist adjuvant MPLA were assessed for their ability to elicit antigen-specific immunity. Using this novel microneedle system we successfully primed antigen-specific responses that were further boosted by an intranasal mucosal inoculation to elicit significant antigen-specific immunity. This prime-boost modality generated similar serum and mucosal gp140-specific IgG levels to the adjuvanted and systemic subcutaneous inoculations. While the microneedle primed groups demonstrated a balanced Th1/Th2 profile, strong Th2 polarization was observed in the subcutaneous inoculation group, likely due to the high level of IL-5 secretion from cells in this group. Significantly, the animals that received a microneedle prime and intranasal boost regimen elicited a high level IgA response in both the serum and mucosa, which was greatly enhanced over the subcutaneous group. The splenocytes from this inoculation group secreted moderate levels of IL-5 and IL-10 as well as high amounts of IL-2, cytokines known to act in synergy to induce IgA. This work opens up the possibility for microneedle-based HIV vaccination strategies that, once fully developed, will greatly reduce risk for vaccinators and patients, with those in the developing world set to benefit most.