Robert Curl

Robert Curl


Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2009 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
RLRafał Lewicki
Rafał Lewicki
JDJames H. Doty
James H. Doty
RCRobert Curl
Robert Curl
FTFrank K. Tittel
Frank K. Tittel
GWGerard Wysocki
Gerard Wysocki
A transportable prototype Faraday rotation spectroscopic system based on a tunable external cavity quantum cascade laser has been developed for ultrasensitive detection of nitric oxide (NO). A broadly tunable laser source allows targeting the optimum Q 3/2 (3/2) molecular transition at 1875.81 cm −1 of the NO fundamental band. For an active optical path of 44 cm and 1-s lock-in time constant minimum NO detection limits (1σ) of 4.3 parts per billion by volume (ppbv) and 0.38 ppbv are obtained by using a thermoelectrically cooled mercury–cadmium–telluride photodetector and liquid nitrogen-cooled indium–antimonide photodetector, respectively. Laboratory performance evaluation and results of continuous, unattended monitoring of atmospheric NO concentration levels are reported.

29 October 2008 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
RCRobert Curl
Robert Curl
MLMi Kyung Lee
Mi Kyung Lee
GSG. E. Scuseria
G. E. Scuseria

1 April 2001 in Journal of Molecular Graphics and Modelling
Verified
Journal Article
Closed access
RCRobert Curl
Robert Curl
RSRichard E Smalley
Richard E Smalley
HKHarold W Kroto
Harold W Kroto
SOSean O’brien
Sean O’brien
JHJames R Heath
James R Heath

3 April 2007 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
JHJiaxiang Han
Jiaxiang Han
Shui-Ming HuShui-Ming Hu
Shui-Ming Hu
HCHongbing Chen
Hongbing Chen
YUYurii Utkin
Yurii Utkin
JBJohn M. Brown
John M. Brown
RCRobert Curl
Robert Curl
Observations of the jet-cooled infrared spectrum of CH3O in the CH stretching region have been extended, down to 2756 cm−1 and up to 3003 cm−1. In the lower frequency extension, a single vibronic band has been assigned. In the higher frequency region, the spectrum becomes complex above 2900 cm−1 and remains so until near 2970 cm−1 where it rapidly becomes sparse. Including the single vibronic band previously reported, a total of four bands have been assigned. Two bands including the original one follow a perpendicular ΔP = +1 rotational selection rule and the other two bands follow a parallel ΔP = 0 selection rule. In addition to these in the congested region between 2900 and 2970 cm−1, ten isolated sub-bands (two P″ = −1/2, two P″ = +1/2, and six P″ = +1.5) have been assigned, but it has so far not been possible to connect these together to form bands. Taken together these observations suggest that there are strong vibronic couplings between the two CH stretching vibrations and the overtone and combination levels in the region.

2 June 1994
Verified
Conference Paper
Closed access
CMCharles E. Miller
Charles E. Miller
WEWode C. Eckhoff
Wode C. Eckhoff
USUlrich Simon
Ulrich Simon
FTFrank K. Tittel
Frank K. Tittel
RCRobert Curl
Robert Curl
We report the results of our efforts to increase the infrared output power from a cw difference frequency generation source based on the nonlinear material AgGaS2 for use in infrared kinetic spectroscopy. Experimental and theoretical infrared conversion efficiencies are compared as a function of pump power, signal power, and focusing conditions. The predicted and observed IR yields agree well for the unfocused beam; however, the agreement is poor (experimental conversion a factor of 3 to 5 less than theory) for all focused conditions. The highest IR output powers obtained corresponded to experimental conditions that are slightly overfocused compared to the theoretical optimum. Thermal loading of the AgGaS2 decreases the parametric conversion efficiency when the power in one of the input lasers beams exceeds approximately 800 mW. Infrared powers of 10 to 30 (mu) W have been achieved near 5.2 micrometers . Future improved crystals should yield powers at the AP 500-(mu) W level.

1 March 2010 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
DMDmitry G. Melnik
Dmitry G. Melnik
MTMadhuri M. Thakur
Madhuri M. Thakur
HBHeather Barnett
Heather Barnett
KDKevin Daly
Kevin Daly
CMChristine H. Moran
Christine H. Moran
RCRobert Curl
Robert Curl
The field of fluorescence imaging for biomedical applications has undergone a dramatic expansion over the past 20years . It is the most rapidly expanding technique employed today, in both the medical and biological sciences,1, 2, 3, 4, 5, 6, 7, 8, 9 a fact that is spurring the development of more sophisticated microscopes10, 11, 12, 13, 14 and wide-field imagers.15 The availability of hundreds of fluorescent labels16, 17 with known excitation and emission curves and well-understood biological structure targets has accelerated the application of fluorescence microscopy in both clinical laboratories and research. These developments allow great flexibility and specificity in what can be imaged. Many fluorescent dyes are compatible with living organisms, making in vivo imaging possible. In particular, functional imaging of a biological process can be achieved3, 4, 5, 18 by selecting a fluorescent label that attaches to a dynamic structure of interest within the sample.