Analysis of stool offers simple, non-invasive monitoring for many gastrointestinal (GI) diseases and access to the gut microbiome, however adherence to stool sampling protocols remains a major challenge because of the prevalent dislike of handling one’s feces. We present a technology that enables individual stool specimen collection from toilet wastewater for fecal protein and molecular assay. Human stool specimens and a benchtop test platform integrated with a commercial toilet were used to demonstrate reliable specimen collection over a wide range of stool consistencies by solid/liquid separation followed by spray-erosion. The obtained fecal suspensions were used to perform occult blood tests for GI cancer screening and for microbiome 16S rRNA analysis. Using occult blood home test kits, we found overall 90% agreement with standard sampling, 96% sensitivity and 86% specificity. Microbiome analysis revealed no significant difference in within-sample species diversity compared to standard sampling and specimen cross-contamination was below the detection limit of the assay. Furthermore, we report on the use of an analogue turbidity sensor to assess in real time loose stools for tracking of diarrhea. Implementation of this technology in residential settings will improve the quality of GI healthcare by facilitating increased adherence to routine stool monitoring.
16 March 2020 in Environmental Science: Water Research & Technology
Demonstration of an electrochemical toilet wastewater treatment and disinfection technology at the scale of an apartment building and translation of the system into a commercial product.
A challenge in water reuse for toilet flushing in India and other Asian countries derives from pour flushing practices. It is a common assumption that the amount of pour flushed water used for personal cleansing is small in comparison to the cistern flush volume, however there is a knowledge gap regarding the actual contribution of each water source to the blackwater amount. In this study, digital water meters were used to measure the fraction of water from personal wash tap relative to cistern water that is used for toilet flushing. High temporal resolution measurements were carried in three different urban sites in the city of Coimbatore in the southern Indian state of Tamil Nadu where onsite sanitation treatment prototypes that may provide reclaimed water for cistern flushing are being tested. Data collected over periods of up to 2 months show that the contribution of the cistern flush to the total blackwater volume is low (14-40%). These data highlight an important factor to inform interventions designed around water reuse for flushing in world geographies where personal toilet cleansing by water is the common practice.
27 February 2021 in Journal of Water, Sanitation and Hygiene for Development
Onsite incinerators offer a promising solution to the challenges of menstrual waste disposal, particularly in institutional settings. However, thermochemical processes are well known to depend on the nature of the feedstocks and their moisture content (MC). An analysis is presented of the physical properties of menstrual waste as potential feedstock for onsite incinerators. Waste was generated in three institutional settings – from women of wide age range and from people with different socioeconomic backgrounds such as workers and students. Over 10 separate collections, 613 discarded menstrual pads were obtained with over 93% of the waste representing commercially disposable pads and less than 7% of the waste appearing to be homemade cloth pads. A surprising finding of this study was that a significant fraction of the commercially disposed pads (23–37%) had a large wet weight (over 20 g) which was associated with MC exceeding 50 wt%. This high MC was attributed to the practice of washing the pads prior to disposal, and it was much higher than what is standard for thermal processing. These data suggest that testing protocols for menstrual waste incinerator technology performance should include an evaluation of the effects of higher MC, unfolded pads, and occasional cloth pads.
Gastrointestinal (GI) conditions are widespread and significantly impact the quality of life and healthcare. Stool appearance is a valuable GI diagnostic indicator, and with the advent of the Internet of Things (IoT), daily monitoring of excreta from a toilet is emerging as a promising digital health tool. This article describes a stool image analysis approach that classifies two physiologically relevant stool characteristics: 1) form and 2) color for an IoT-based smart toilet. We constructed a stool image data set with 3275 images, spanning all seven types of the Bristol stool-form scale (BSFS), a widely used metric for stool consistency and a variety of colors. We used ground-truth data obtained through the annotation of our data set by two gastroenterologists and developed a stool-color card to standardize the labeling of stool colors. We addressed two limitations associated with the application of computer-vision techniques to a smart-toilet system: 1) uneven separability between different stool-form categories and 2) class imbalance in the data set. We present results on hierarchical convolutional neural network (CNN) architectures for training a stool-form classifier and on perceptual color quantization coupled with machine-learning techniques to optimize the color-feature space for the classification of stool color. We utilized an edge–cloud approach to pursue an optimal balance between accuracy and latency and for the classification of stool form, we achieved a balanced accuracy of 84.4% and 84.2% reduction in latency compared to a cloud-model only. For color classification, the logistic-regression (LR) classifier provided 80.8% balanced accuracy and 47.3% reduction in communication latency.