Muhammad Muinul Islam

Dr. Muhammad Muinul Islam

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2017 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MIMuhammad Muinul Islam
Muhammad Muinul Islam
TTTetsuya Tsujikawa
Tetsuya Tsujikawa
TMTetsuya Mori
Tetsuya Mori
YKYasushi Kiyono
Yasushi Kiyono
Hidehiko OkazawaHidehiko Okazawa
Hidehiko Okazawa
A noninvasive method to estimate input function directly from (H2O)-O-15 brain PET data for measurement of cerebral blood flow (CBF) was proposed in this study. The image derived input function (IDIF) method extracted the time-activity curves (TAC) of the major cerebral arteries at the skull base from the dynamic PET data. The extracted primordial IDIF showed almost the same radioactivity as the arterial input function (AIF) from sampled blood at the plateau part in the later phase, but significantly lower radioactivity in the initial arterial phase compared with that of AIF-TAC. To correct the initial part of the IDIF, a dispersion function was applied and two constants for the correction were determined by fitting with the individual AIF in 15 patients with unilateral arterial stenoocclusive lesions. The area under the curves (AUC) from the two input functions showed good agreement with the mean AUC(IDIF)/AUC(AIF) ratio of 0.92 +/- 0.09. The final products of CBF and arterialto-capillary vascular volume (V-0) obtained from the IDIF and AIF showed no difference, and had with high correlation coefficients.

27 February 2017 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MIMuhammad Muinul Islam
Muhammad Muinul Islam
TTTetsuya Tsujikawa
Tetsuya Tsujikawa
TMTetsuya Mori
Tetsuya Mori
YKYasushi Kiyono
Yasushi Kiyono
Hidehiko OkazawaHidehiko Okazawa
Hidehiko Okazawa
Objective A new method of delay time estimation was proposed to measure precise cerebral blood flow (CBF) and arterial-to-capillary blood volume (V 0) using 15O-water PET. Methods Nineteen patients with unilateral arterial stenoocclusive lesions were studied to evaluate hemodynamic status before treatment. The delay time of each pixel was calculated using least squares fitting with an arterial blood input curve adjusted to the internal carotid artery counts at the skull base. Pixel-by-pixel delay estimation provided a delay map image that could be used for precise calculation of CBF and V 0 using a one-tissue compartment model, and the values from this method were compared with those from the slice-by-slice correction method. Results The affected side showed a longer delay time than the contralateral cerebral hemisphere. Although the mean cortical CBF values were not different between the two methods, the slice-by-slice delay correction overestimated CBF in the hypo perfused area. The scatter plot of V 0 pixel values showed significant difference between the two correction methods where the slice-by-slice delay correction significantly overestimated V 0 in the whole brain (P < 0.05). Conclusion Pixel-by-pixel delay correction provides delay images as well as better estimation of CBF and V 0, thus offering useful and beneficial information for the treatment of cerebrovascular disease.

1 October 2018 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MRMahmudur G. M. Rahman
Mahmudur G. M. Rahman
MIMuhammad Muinul Islam
Muhammad Muinul Islam
TTTetsuya Tsujikawa
Tetsuya Tsujikawa
YKYasushi Kiyono
Yasushi Kiyono
Hidehiko OkazawaHidehiko Okazawa
Hidehiko Okazawa
To calculate the specific binding ratio (SBR) appropriately in dopamine transporter (DAT) imaging, a method for extracting the striatal volume of interest (VOI) was developed.

30 September 2010 in Gut and Liver
Verified
Journal Article
Open access
PDF file
JYJaved Yakoob
Javed Yakoob
ZAZaigham Abbas
Zaigham Abbas
SNShagufta Naz
Shagufta Naz
MIMuhammad Muinul Islam
Muhammad Muinul Islam
SAShahab Abid
Shahab Abid
WJWasim Jafri
Wasim Jafri
Yakoob J, et al. Gut Liver. 2010 Sep;4(3):345-350. http://dx.doi.org/10.5009/gnl.2010.4.3.345

24 February 2022
Verified
Conference Paper
Closed access
RRReana Raen
Reana Raen
MIMuhammad Muinul Islam
Muhammad Muinul Islam
RIRedwanul Islam
Redwanul Islam
Optical Coherence Tomography (OCT) was first introduced in the 1990’. It utilizes the concept of interferometry to create a cross-sectional map of the retina., accurate within 10–15 microns. Identifying the actual diseases occurring in retina layer., is a challenging task. There exist several automated techniques for disease classification like image processing., deep learning. Unfortunately., these techniques often produce error., lower precision., excessive memory localization., inefficiency in computation., further interpretation of human experts. In this paper., we have proposed a method for automatic classification of 3 categories of retinal diseases that include diabetic macular edema., Drusen., Choroidal Neovascularization. A modified ResNet architecture with transfer learning framework is used to make better feature extraction for small patches. This modification includes adding three new layers which are Convolution layer., Batch Normalization and Activation function relu layers. Modification is added at the end of convolution layers in a pretrained Resnet framework. These layers are inserted in the ResNet50 architecture for accurate discrimination and robust feature extraction of OCT images with better efficiency than the traditional networks. Experimental results demonstrate that our method obtained accuracy value 99.81%. Our proposed model provides reliable classification for small lesions., helpful in clinical diagnostic to provide user-friendly eye check-ups.

1 October 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
CIChiaki Igarashi
Chiaki Igarashi
Hidehiko OkazawaHidehiko Okazawa
Hidehiko Okazawa
MIMuhammad Muinul Islam
Muhammad Muinul Islam
TTTetsuya Tsujikawa
Tetsuya Tsujikawa
THToshifumi Higashino
Toshifumi Higashino
KKKen-Ichiro Kikuta
Ken-Ichiro Kikuta
To clarify the differences in hemodynamic status between atherosclerotic steno-occlusive lesions (SOL) and moyamoaya disease (MMD), hemodynamic parameters were compared using 15O-PET. Twenty-four patients with unilateral SOL (67 ± 11 y) and eighteen with MMD (33 ± 16 y) were assigned to this study. MMD patients were divided into twelve unilateral and six bilateral lesions. All patients underwent 15O-PET to measure cerebral blood flow (CBF), blood volume (CBV), oxygen extraction fraction (OEF), and metabolic rate (CMRO2). Acetazolamide was administered after the baseline scan and the second 15O-water PET was performed to evaluate cerebrovascular reactivity (CVR). For the CBF calculation in 15O-water PET, the three-weighted integral method was applied based on a one-tissue compartment model with pixel-by-pixel delay correction to measure precise CBF and arterial-to-capillary blood volume (V0). Baseline hemodynamic parameters showed significantly lower CBF, V0, and CMRO2, but greater CBV, OEF, and delay (p < 0.01) in the affected hemispheres than in the unaffected hemispheres. After ACZ administration, both hemispheres showed a significant increase in CBF (p < 0.0001), but not in V0. CVR differed significantly between the hemispheres. The arterial perfusion pressure of the functioning arterial part tended to be reduced after acetazolamide administration in patients with past neurologic events caused by hemodynamic impairment. MMD patients showed greater inactive vascular and venous volumes compared with common atherosclerotic SOL patients. The hemodynamic status of cerebral circulation may vary according to the chronic process of steno-occlusive change and the development of collateral circulation. In order to evaluate physiologic differences between the two diseases, 15O-PET with an acetazolamide challenge test is useful.