Teresa Simón-Yarza

Dr. Teresa Simón-Yarza

Laboratory for Vascular Translational Science INSERM U1148 - Université de Paris, F-75018 Paris, France
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2018 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
Teresa Simón-YarzaTeresa Simón-Yarza
Teresa Simón-Yarza
AMAngelika Mielcarek
Angelika Mielcarek
PCPatrick Couvreur
Patrick Couvreur
CSChristian Serre
Christian Serre

31 August 2020 in Advanced Healthcare Materials
Verified
Journal Article
Open access
PDF file
PAPaola Aprile
Paola Aprile
Didier LetourneurDidier Letourneur
Didier Letourneur
Teresa Simón-YarzaTeresa Simón-Yarza
Teresa Simón-Yarza
Bone resorption can negatively influence the osseointegration of dental implants. Barrier membranes for guided bone regeneration (GBR) are used to exclude nonosteogenic tissues from influencing the bone healing process. In addition to the existing barrier membranes available on the market, a growing variety of membranes for GBR with tailorable physicochemical properties are under preclinical evaluation. Hence, the aim of this review is to provide a comprehensive description of materials used for GBR and to report the main industrial and regulatory aspects allowing the commercialization of these medical devices (MDs). In particular, a summary of the main attributes defining a GBR membrane is reported along with a description of commercially available and under development membranes. Finally, strategies for the scaling‐up of the manufacturing process and the regulatory framework of the main MD producers (USA, EU, Japan, China, and India) are presented. The description of the regulatory approval process of GBR membranes is representative of the typical path that medium‐ to high‐risk MDs have to follow for an effective medical translation, which is of fundamental importance to increase the impact of biomedical research on public health.

28 September 2017 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
Teresa Simón-YarzaTeresa Simón-Yarza
Teresa Simón-Yarza
MMMónica Giménez Marqués
Mónica Giménez Marqués
RMRhizlaine Mrimi
Rhizlaine Mrimi
AMAngelika Mielcarek
Angelika Mielcarek
Ruxandra GrefRuxandra Gref
Ruxandra Gref
PCPatrick Couvreur
Patrick Couvreur

5 August 2021 in Advanced Science
Verified
Journal Article
Open access
PDF file
ADAlessandra Dellaquila
Alessandra Dellaquila
CBChau Le Bao
Chau Le Bao
Didier LetourneurDidier Letourneur
Didier Letourneur
Teresa Simón-YarzaTeresa Simón-Yarza
Teresa Simón-Yarza
Vascularization of 3D models represents a major challenge of tissue engineering and a key prerequisite for their clinical and industrial application. The use of prevascularized models built from dedicated materials could solve some of the actual limitations, such as suboptimal integration of the bioconstructs within the host tissue, and would provide more in vivo‐like perfusable tissue and organ‐specific platforms. In the last decade, the fabrication of vascularized physiologically relevant 3D constructs has been attempted by numerous tissue engineering strategies, which are classified here in microfluidic technology, 3D coculture models, namely, spheroids and organoids, and biofabrication. In this review, the recent advancements in prevascularization techniques and the increasing use of natural and synthetic materials to build physiological organ‐specific models are discussed. Current drawbacks of each technology, future perspectives, and translation of vascularized tissue constructs toward clinics, pharmaceutical field, and industry are also presented. By combining complementary strategies, these models are envisioned to be successfully used for regenerative medicine and drug development in a near future.

5 July 2018 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
DKDenise Karamessini
Denise Karamessini
Teresa Simón-YarzaTeresa Simón-Yarza
Teresa Simón-Yarza
SPSalomé Poyer
Salomé Poyer
EKEvgeniia Konishcheva
Evgeniia Konishcheva
LCLaurence Charles
Laurence Charles
JLJean‐François Lutz
Jean‐François Lutz

9 May 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MAM. Atlan
M. Atlan
Teresa Simón-YarzaTeresa Simón-Yarza
Teresa Simón-Yarza
JIJ. M. Ino
J. M. Ino
VHV. Hunsinger
V. Hunsinger
LCL. Corté
L. Corté
Didier LetourneurDidier Letourneur
Didier Letourneur
Since the development of the first vascular grafts, fabrication of vessel replacements with diameters smaller than 6 mm remains a challenge. The present work aimed to develop PVA (poly (vinyl alcohol))-gelatin hybrids as tubes suitable for replacement of very small vessels and to evaluate their performance using a rat abdominal aorta interposition model. PVA-gelatin hybrid tubes with internal and external diameters of 1.4 mm and 1.8 mm, respectively, composed of 4 different gelatin ratios were prepared using a one-step strategy with both chemical and physical crosslinking. By 3D Time of Flight MRI, Doppler-Ultrasound, Computed Tomography angiography and histology, we demonstrated good patency rates with the 1% gelatin composition until the end of the study at 3 months (50% compared to 0% of PVA control grafts). A reduction of the patency rate during the time of implantation suggested some loss of properties of the hybrid material in vivo, further confirmed by mechanical evaluation until one year. In particular, stiffening and reduction of compliance of the PVA-gelatin grafts was demonstrated, which might explain the observed long-term changes in patency rate. These encouraging results confirm the potential of PVA-gelatin hybrids as ready-to-use vascular grafts for very small vessel replacement.