Sohee Jeon

Dr. Sohee Jeon


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Progress in Retinal and Eye Research
Verified
Journal Article
Closed access
JLJi-Peng Olivia Li
Ji-Peng Olivia Li
HLHanruo Liu
Hanruo Liu
DTDarren S.J. Ting
Darren S.J. Ting
SJSohee Jeon
Sohee Jeon
RCR.V. Paul Chan
R.V. Paul Chan
DTDaniel S.W. Ting
Daniel S.W. Ting

7 July 2022 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
SJSohee Jeon
Sohee Jeon
ACAyoung Choi
Ayoung Choi
HKHyunggoo Kwon
Hyunggoo Kwon

28 November 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SJSohee Jeon
Sohee Jeon
ACAyoung Choi
Ayoung Choi
HKHyunggoo Kwon
Hyunggoo Kwon
A newly developed extended-depth-of-focus AcrySof® Vivity™ intraocular lens (IOL), which has a wavefront-shaped anterior surface, has shown a promising outcome in minimizing dysphotopsia, the biggest issue after diffractive type IOL implantation. On the contrary, relatively low uncorrected near visual acuity (UNVA) has been raised as a demerit of this IOL. However, there is only limited information about the UNVA after Vivity implantation. In the present study, we compared the uncorrected distant and intermediate visual acuity (UDVA and UIVA) and UNVA according to the range of refractive error (RE) from 91 eyes from 91 patients implanted with Vivity IOL. Then we assessed the biometric factors for their association with UNVA from 66 eyes with a RE within ± 0.25 D. The UDVA was worst in eyes with RE < -0.50 D (0.17 ± 0.21), which was significantly worse than in any other group (P < 0.001 for every analysis). The UIVA was worst in eyes with RE of 0.25 to 0.50 D (0.35 ± 0.07 D), which was significantly worse than in eyes with RE of -0.50 to -0.26 D (P = 0.020) and in eyes with RE of -0.25 to -0.01 D (P = 0.028). The UNVA was worst in eyes with RE of 0.25 to 0.50 D (0.40 ± 0.14 D), which was significantly worse than in eyes with RE of -0.50 to -0.26 D (P = 0.022), which suggests that the extent of monovision should be limited up to -0.50 diopter. On univariate analysis for UNVA in eyes with a RE within ± 0.25 D, the anterior chamber depth (R = 0.257; P = 0.037) and pupil size (R = 0.451; P < 0.001) had a statistically significant relation to UNVA, while multivariate analysis showed the pupil size (β = 0.451; P < 0.001) as the sole indicator, suggesting eyes with a small pupil size might receive a UNVA benefit.

1 March 2021 in Ophthalmology Retina
Verified
Journal Article
Closed access
JPJin Heung Park
Jin Heung Park
HYHyeontak Yang
Hyeontak Yang
HKHyunggoo Kwon
Hyunggoo Kwon
SJSohee Jeon
Sohee Jeon

1 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ACAyoung Choi
Ayoung Choi
HKHyunggoo Kwon
Hyunggoo Kwon
SJSohee Jeon
Sohee Jeon
The accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q, and Haigis) for the Acrysof IQ Panoptix TFNT IOL (Alcon Laboratories, Inc, Fort Worth, Texas, United States) implantation based on the axial length (AXL) from a large cohort of 2018 cases and identify the factors that are associated with a high mean absolute error (MAE). The Barrett Universal II showed the lowest MAE in the normal AXL group (0.30 ± 0.23), whereas the Holladay 1 and Hoffer Q showed the lowest MAE in the short AXL group (0.32 ± 0.22 D and 0.32 ± 0.21 D, respectively). The Haigis showed the lowest MAE in the long AXL group (0.24 ± 0.19 D). The Barrett Universal II did not perform well in short AXL eyes with higher astigmatism (P = 0.013), wider white-to-white (WTW; P < 0.001), and shorter AXL (P = 0.016). Study results suggest that the Barrett Universal II performed best for the TFNT IOL in the overall study population, except for the eyes with short AXL, particularly when the eyes had higher astigmatism, wider WTW, and shorter AXL.

20 July 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKSoonil Kwon
Soonil Kwon
BKBoyun Kim
Boyun Kim
SJSohee Jeon
Sohee Jeon
While the precise diagnosis of early stage epiretinal membrane (ERM) at the time of cataract surgery and evaluation of risk factors for development or progression of ERM after cataract surgery is increasingly important, there is only limited information. In the present study, we evaluated the risk factors for onset or progression of ERM on spectral domain optical coherence tomography (SD-OCT) after cataract surgery. The univariate analysis showed that eyes with partial posterior vitreous detachment (PVD; p < 0.001), hyper-reflective foci (HF) on the inner retinal surface (p < 0.001), vitreoschisis (p = 0.014), and discrete margin of different retinal reflectivity (DMDRR; p = 0.007) on ultra-widefield fundus photography (UWF-FP) had significant risk for the onset or progression of ERM after cataract surgery. The multivariate analysis showed that partial PVD (HR, 3.743; 95% confidence interval [CI], 1.956–7.162; p < 0.001), HF (HR, 2.330; 95% CI, 1.281–4.239; p = 0.006), and DMDRR on UWF-FP (HR, 3.392; 95% CI, 1.522–7.558; p = 0.003) were the independent risk factors for the onset or progression of ERM after cataract surgery after adjustment for other confounding factors. Our study shows that the onset or progression of ERM after cataract surgery depends on an abnormal vitreoretinal interface (VRI) represented by partial PVD, HF on SD-OCT, and DMDRR on UWF-FP, not on age, axial length, or presence of ERM at the time of surgery. A meticulous funduscopic evaluation of the VRI would help to predict the ERM risk before cataract surgery.