Sacha Noimark

Dr. Sacha Noimark

University College London, London, City of London, UK
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2017 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
JGJames A. Guggenheim
James A. Guggenheim
JLJing Li
Jing Li
TAThomas J. Allen
Thomas J. Allen
RCRichard Colchester
Richard Colchester
SNSacha Noimark
Sacha Noimark
PBPaul C. Beard
Paul C. Beard

15 January 2018 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
SNSacha Noimark
Sacha Noimark
RCRichard Colchester
Richard Colchester
RPRadhika K. Poduval
Radhika K. Poduval
EMEfthymios Maneas
Efthymios Maneas
EAErwin J. Alles
Erwin J. Alles
ADAdrien Desjardins
Adrien Desjardins

3 April 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RCRichard Colchester
Richard Colchester
CLCallum Little
Callum Little
GDGeorge Dwyer
George Dwyer
SNSacha Noimark
Sacha Noimark
EAErwin J Alles
Erwin J Alles
ADAdrien Desjardins
Adrien Desjardins
Miniaturised high-resolution imaging devices are valuable for guiding minimally invasive procedures such as vascular stent placements. Here, we present all-optical rotational B-mode pulse-echo ultrasound imaging. With this device, ultrasound transmission and reception are performed with light. The all-optical transducer in the probe comprised an optical fibre that delivered pulsed excitation light to an optical head at the distal end with a multi-walled carbon nanotube and polydimethylsiloxane composite coating. This coating was photoacoustically excited to generate a highly directional ultrasound beam perpendicular to the optical fibre axis. A concave Fabry-Pérot cavity at the distal end of an optical fibre, which was interrogated with a tuneable continuous-wave laser, served as an omnidirectional ultrasound receiver. The transmitted ultrasound had a −6 dB bandwidth of 31.3 MHz and a peak-to-peak pressure of 1.87 MPa, as measured at 1.5 mm from the probe. The receiver had a noise equivalent pressure <100 Pa over a 20 MHz bandwidth. With a maximum outer probe diameter of 1.25 mm, the probe provided imaging with an axial resolution better than 50 µm, and a real-time imaging rate of 5 frames per second. To investigate the capabilities of the probe, intraluminal imaging was performed in healthy swine carotid arteries. The results demonstrate that the all-optical probe is viable for clinical rotational ultrasound imaging.

23 September 2016 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
SNSacha Noimark
Sacha Noimark
ESEnrico Salvadori
Enrico Salvadori
RGRafael Gómez-Bombarelli
Rafael Gómez-Bombarelli
AMAlexander J. MacRobert
Alexander J. MacRobert
IPIvan P. Parkin
Ivan P. Parkin
CKChristopher W. M. Kay
Christopher W. M. Kay
Surfaces with built-in antimicrobial activity have the potential to reduce hospital-acquired infections. One promising strategy is to create functionalised surfaces which, following illumination with visible light, are able to generate singlet oxygen under aerobic conditions. In contrast to antibiotics, the mechanism of bacterial kill by species derived from reactions with singlet oxygen is completely unselective, therefore offering little room for evolutionary adaptation. Here we consider five commercially available organic photosensitiser dyes encapsulated in silicone polymer that show varied antimicrobial activity. We correlate density functional theory calculations with UV-Vis spectroscopy, electron paramagnetic resonance spectroscopy and singlet oxygen production measurements in order to define and test the elements required for efficacious antimicrobial activity. Our approach forms the basis for the rational in silico design and spectroscopic screening of simple and efficient self-sterilising surfaces made from cheap, low toxicity photosensitiser dyes encapsulated in silicone.

26 April 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EAErwin J Alles
Erwin J Alles
NSNora Fook Sheung
Nora Fook Sheung
SNSacha Noimark
Sacha Noimark
EZEdward Z. Zhang
Edward Z. Zhang
PBPaul C. Beard
Paul C. Beard
ADAdrien Desjardins
Adrien Desjardins
A miniature all-optical ultrasound imaging system is presented that generates three-dimensional images using a stationary, real acoustic source aperture. Discrete acoustic sources were sequentially addressed by scanning a focussed optical beam across the proximal end of a coherent fibre bundle; high-frequency ultrasound (156% fractional bandwidth centred around 13.5 MHz) was generated photoacoustically in the corresponding regions of an optically absorbing coating deposited at the distal end. Paired with a single fibre-optic ultrasound detector, the imaging probe (3.5 mm outer diameter) achieved high on-axis resolutions of 97 μm, 179 μm and 110 μm in thex,yandzdirections, respectively. Furthermore, the optical scan pattern, and thus the acoustic source array geometry, was readily reconfigured. Implementing four different array geometries revealed a strong dependency of the image quality on the source location pattern. Thus, by employing optical technology, a miniature ultrasound probe was fabricated that allows for arbitrary source array geometries, which is suitable for three-dimensional endoscopic and laparoscopic imaging, as was demonstrated onex vivoporcine cardiac tissue.

17 September 2023 in Advanced Functional Materials
Verified
Journal Article
Open access
ZLZhi Li
Zhi Li
JCJoanna. M. Coote
Joanna. M. Coote
SSSwathika Subburaman
Swathika Subburaman
Francesco IacovielloFrancesco Iacoviello
Francesco Iacoviello
KPKristopher Page
Kristopher Page
SNSacha Noimark
Sacha Noimark
Smart robotic devices remotely powered by magnetic field have emerged as versatile tools for wide biomedical applications. Soft magnetic elastomer (ME) composite membranes with high flexibility and responsiveness are frequently incorporated to enable local actuation for wireless sensing or cargo delivery. However, the fabrication of thin ME membranes with good control in geometry and uniformity remains challenging, as well as the optimization of their actuating performances under low fields (milli‐Tesla). In this work, the development of ME membranes comprising of low‐cost magnetic powder and highly soft elastomer through a simple template‐assisted doctor blading approach, is reported. The fabricated ME membranes are controllable in size (up to centimetre‐scale), thickness (tens of microns) and high particle loading (up to 70 wt.%). Conflicting trade‐off effects of particle concentration upon magnetic responsiveness and mechanical stiffness are investigated and found to be balanced off as it exceeds 60 wt.%. A highly sensitive fibre‐optic interferometric sensing system and a customized fibre‐ferrule‐membrane probe are first proposed to enable dynamic actuation and real‐time displacement characterization. Free‐standing ME membranes are magnetically excited under low field down to 2 mT, and optically monitored with nanometer accuracy. The fast and consistent responses of ME membranes showcase their promising biomedical applications in nanoscale actuation and sensing.