Chul Young Choi

Chul Young Choi


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2017 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
BGBert C. Giers
Bert C. Giers
TTTamer Tandogan
Tamer Tandogan
GAGerd U. Auffarth
Gerd U. Auffarth
CCChul Young Choi
Chul Young Choi
FAFlorian N. Auerbach
Florian N. Auerbach
Ramin KhoramniaRamin Khoramnia
Ramin Khoramnia
Laboratory analysis and optical quality assessment of explanted hydrophilic intraocular lenses (IOLs) with clinically significant opacification after posterior lamellar keratoplasty (DMEK and DSAEK). Thirteen opacified IOLs after posterior lamellar keratoplasty, 8 after descemet stripping automated endothelial keratoplasty (DSAEK), 3 after descemet membrane endothelial keratoplasty (DMEK) and 2 after both DSAEK and DMEK were analysed in our laboratory. Analyses included optical bench assessment for optical quality, light microscopy, scanning electron microscopy (SEM) and energy dispersive X-Ray spectroscopy (EDS). In all IOLs the opacification was caused by a thin layer of calciumphosphate that had accumulated underneath the anterior optical surface of the IOLs in the area spared by the pupil/anterior capsulorhexis. The calcifications lead to a significant deterioration of the modulation transfer function across all spatial frequencies of the affected IOLs. The instillation of exogenous material such as air or gas into the anterior chamber increases the risk for opacification of hydrophilic IOLs irrespective of the manufacturer or the exact composition of the hydrophilic lens material. It is recommended to avoid the use of hydrophilic acrylic IOLs in patients with endothelial dystrophy that will likely require procedures involving the intracameral instillation of air or gas, such as DMEK or DS(A)EK.

19 August 2019 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
HSHyeck-Soo Son
Hyeck-Soo Son
SKSeong Ho Kim
Seong Ho Kim
GAGerd U. Auffarth
Gerd U. Auffarth
CCChul Young Choi
Chul Young Choi
To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform.

1 May 2016 in Experimental Eye Research
Verified
Journal Article
Closed access
MNMatthias Nobl
Matthias Nobl
MRMichael Reich
Michael Reich
IDIvanka Dacheva
Ivanka Dacheva
JSJustyna Siwy
Justyna Siwy
WMWilliam Mullen
William Mullen
MKMichael J. Koss
Michael J. Koss

9 September 2008 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
MKM S Kim
M S Kim
CCChul Young Choi
Chul Young Choi
JKJ M Kim
J M Kim
HCH R Chung
H R Chung
HWH Y Woo
H Y Woo
Background/aims: To evaluate microbial contamination of multiply used preservative-free artificial tears packed in reclosable containers after daily use. Methods: Subjects were provided with preservative-free artificial tears (Groups 1 and 2) and artificial tears containing a preservative (Group 3). After administration three times or more per 10 h, bottles were collected, and any remaining fluid in the bottles was cultured. A risk factor analysis for microbial contamination was performed by the use of univariate and multivariate analysis. Results: A total of 242 eye-drop bottles were evaluated. Five (2.0%) of the 242 bottles had bacterial contamination. In group 1, four (3.9%) of 102 bottles were contaminated, and identified bacteria were all coagulase-negative Staphylococcus. In group 2, one (1.0%) of 105 bottles was contaminated, and it was a Gram-negative Acinetobacter species. No bottles from group 3 showed any contamination. Based on multivariate analysis, advanced age and fingertip touch were statistically significant risk factors for microbial contamination (p<0.05). Conclusion: Preservative-free artificial tears in reclosable containers are at risk of contamination in a daily and multiple use setting, especially in patients with a poor administering technique, which is associated with fingertip touch and advanced age.

1 May 2015 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YLYong Woo Lee
Yong Woo Lee
CCChul Young Choi
Chul Young Choi
GYGeun Young Yoon
Geun Young Yoon
To compare measurements of corneal indices using dual rotating Scheimpflug-Placido, swept-source optical coherence tomography (OCT), and Placido-scanning-slit systems. Kangbuk Samsung Hospital, Seoul, South Korea. Prospective evaluation of diagnostic tests. Corneal topography measurements were performed using dual rotating Scheimpflug-Placido (Galilei G2), swept-source OCT (Casia SS-1000), and Placido-scanning-slit (Orbscan IIz) systems. The intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate the agreement between measurements. Fifty post-refractive surgery eyes and 50 normal eyes were evaluated. The agreement in anterior keratometry and pachymetry between the 3 devices was high in both groups (ICC > 0.9). In both groups, the ICC values for posterior keratometry and eccentricity were high between the dual rotating Scheimpflug-Placido and swept-source OCT systems (ICC > 0.9) but not between the Placido-scanning-slit system and the other 2 systems. The Placido-scanning-slit system yielded much steeper values for posterior keratometry in both groups (P < .05). The ICC values for posterior corneal elevation were lower than 0.9 between all 3 devices. The dual rotating Scheimpflug-Placido and swept-source OCT systems showed relatively higher ICC values than the Placido-scanning-slit system in both groups. Maximum posterior elevations were highest with the Placido-scanning-slit system followed by the swept-source OCT system and then the dual rotating Scheimpflug-Placido system. Anterior keratometry obtained using 3 devices showed high degrees of agreement. Posterior keratometry and eccentricity showed greater agreement between the dual rotating Scheimpflug-Placido and swept-source OCT systems than with the Placido-scanning-slit system. The dual rotating Scheimpflug-Placido and swept-source OCT systems were equivalent in detecting the shape of the cornea and could be considered interchangeable.

14 February 2020 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
SCSue Hey Chae
Sue Hey Chae
HSHyeck Soo Son
Hyeck Soo Son
Ramin KhoramniaRamin Khoramnia
Ramin Khoramnia
KLKyung Heon Lee
Kyung Heon Lee
CCChul Young Choi
Chul Young Choi
Background: To experimentally compare the optical performance of two different Extended-Depth-of-Focus (EDOF) intraocular lenses (IOLs) using a standardized optical bench set-up. Methods: In this experimental study, following IOLs were assessed: the TECNIS® Symfony ZXR00 (Johnson&Johnson, Santa Ana, USA) and the AT LARA 829MP (Carl Zeiss Meditec, Jena, Germany) IOLs. The through-focus modulation transfer function (MTF) values were measured at a spatial frequency of 50 lp/mm and at aperture sizes of 2, 3, and 4.5 mm. Each IOL was measured while centered using ISO 11979-2 Model 1 (aberration-free) and Model 2 (+ 0.28 μm spherical aberration) corneas. United States Air Force (USAF) target images were also recorded for a qualitative evaluation. Results: At 2 mm pupil with ISO1 cornea, the primary and secondary foci of both IOLs appeared to merge, providing an elongated depth of focus. At 3 and 4.5 mm pupil sizes, the through-focus MTF curves of both IOLs showed a bifocal-like V-pattern. While the Symfony IOL showed an overall superior MTF values when measured with the ISO2 cornea, the opposite propensity could be observed with the AT LARA IOL. This optical behavior could be qualitatively confirmed by the USAF target images. Conclusions: Although the two EDOF IOLs share similarities in their optical properties, the main difference lies in their optical design and performance with respect to spherical aberration. Such characteristics should be taken into account during IOL and patient selection.