po-yu chu

Mr. po-yu chu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
PCpo-yu chu
po-yu chu
JHJason Chia-Hsun Hsieh
Jason Chia-Hsun Hsieh
CLChien-Ru Lin
Chien-Ru Lin
Min-Hsien WuMin-Hsien Wu
Min-Hsien Wu
Cell manipulation using optically induced dielectrophoresis (ODEP) in microfluidic systems has attracted the interest of scientists due to its simplicity. Although this technique has been successfully demonstrated for various applications, one fundamental issue has to be addressed—Whether, the ODEP field affects the native properties of cells. To address this issue, we explored the effect of ODEP electrical conditions on cellular properties. Within the experimental conditions tested, the ODEP-based cell manipulation with the largest velocity occurred at 10 Vpp and 1 MHz, for the two cancer cell types explored. Under this operating condition, however, the cell viability of cancer cells was significantly affected (e.g., 70.5 ± 10.0% and 50.6 ± 9.2% reduction for the PC-3 and SK-BR-3 cancer cells, respectively). Conversely, the exposure of cancer cells to the ODEP electrical conditions of 7–10 Vpp and 3–5 MHz did not significantly alter the cell viability, cell metabolic activity, and the EpCAM, VIM, and ABCC1 gene expression of cancer cells. Overall, this study fundamentally investigated the effect of ODEP electrical conditions on the cellular properties of cancer cells. The information obtained is crucially important for the utilization of ODEP-based cell manipulation in a microscale system for various applications.

21 July 2017
Verified
Conference Paper
Open access
PCPing-Hei Chen
Ping-Hei Chen
Min-Hsien WuMin-Hsien Wu
Min-Hsien Wu
TCTzu-Keng Chiu
Tzu-Keng Chiu
WCWen-Pin Chou
Wen-Pin Chou
CLChia-Jung Liao
Chia-Jung Liao
JHJia-Long Hong
Jia-Long Hong
This study integrated the microfluidic system and ODEP technology for the isolation of CTC clusters from the background leukocytes. The working principle is based on the size difference between the CTC clusters and leukocytes, and thus different magnitude of ODEP force acting on them. ODEP mainly use a controllable light pattern, acting as a virtual electrode, to generate a non-uniform electric field that is in turn utilized to manipulate the electrically-polarized cells. The utilization of ODEP-based mechanism for CTCs isolation has been successfully demonstrated in our previous study [1]. Since 1970, a series of clinical studies have shown that single CTCs may not be the main cause of cancer metastasis, but two or more aggregated CTCs [2, 3]. In order to isolate CTC clusters for back-end analysis. For the biological-based methods (e.g. HBCTC-Chip [4], or CTC-iChip [5]), although CTC clusters can be specifically separated by antibody-based schemes, but the surface-area-to-volume ratio of CTC clusters is relatively low which might affect the binding efficiency of CTC clusters and antibody. Alternatively, some studies proposed physical-based methods to separate CTC clusters (e.g. ISET [6], FMSA [7], Cluster-chip [8]). Although these methods have been demonstrated to effectively isolate the CTC clusters from the background cells mainly based on their size difference, the influence of shear stress on physical size of CTC cluster, or the viability of the cells isolated is still a problem. To address this issue, The key advantages of ODEP mechanism for cell isolation including: (1) no need of complex microfabrication process for constructing microfilter structures, and (2) the reduction of shear stress acting on the cells manipulated. However, the feasibility of using ODEP-based mechanism for the isolation of CTC cluster (i.e. CTC cell aggregates) has not yet been explored. To test its feasibility, a T-shaped microfluidic chip was designed (Fig.1). A virtual microfilter consisting of multiple light patterns was designed at the CTC clusters isolation zone (Fig.1). By continuously moving and rotating the light patterns in the microfilter, the larger CTC clusters can be separated from the background leukocytes, and also transported to the side microchannel (Fig.2). In this work, the optimum ODEP operating conditions (e.g. moving velocity of light pattern) was explored. Results revealed that moving velocity of light pattern that can manipulate the CTC clusters (containing 2-13 cells) was significantly higher than the background of leukocytes (Fig.3). Based on this, the moving velocity of light pattern was set at 100 μm/sec (Fig.3). At a given sample flow rate of 0.5 μl/min, moreover, we found that the rotation speed of light patterns at 14 RPM could significantly increase the purity of CTC clusters isolation (Fig.4). Based on the set operating conditions, the recovery and purity of the isolated CTC clusters were experimentally evaluated to be 70.1 ± 7.1% and 60.8 ± 2.7%, respectively (Fig.4). As a whole, we have established a high purity CTC clusters isolation method that is easy to operate, and is possible to avoid the problem caused by the shear stress acting on the cells or particles.

21 July 2017
Verified
Conference Paper
Open access
Min-Hsien WuMin-Hsien Wu
Min-Hsien Wu
TCTzu-Keng Chiu
Tzu-Keng Chiu
WCWen-Pin Chou
Wen-Pin Chou
CLChia-Jung Liao
Chia-Jung Liao
PCpo-yu chu
po-yu chu
JHJia-Long Hong
Jia-Long Hong
This study integrated the microfluidic system and ODEP technology for the isolation of CTC clusters from the background leukocytes. The working principle is based on the size difference between the CTC clusters and leukocytes, and thus different magnitude of ODEP force acting on them. ODEP mainly use a controllable light pattern, acting as a virtual electrode, to generate a non-uniform electric field that is in turn utilized to manipulate the electrically-polarized cells. The utilization of ODEP-based mechanism for CTCs isolation has been successfully demonstrated in our previous study [1]. Since 1970, a series of clinical studies have shown that single CTCs may not be the main cause of cancer metastasis, but two or more aggregated CTCs [2, 3]. In order to isolate CTC clusters for back-end analysis. For the biological-based methods (e.g. HBCTC-Chip [4], or CTC-iChip [5]), although CTC clusters can be specifically separated by antibody-based schemes, but the surface-area-to-volume ratio of CTC clusters is relatively low which might affect the binding efficiency of CTC clusters and antibody. Alternatively, some studies proposed physical-based methods to separate CTC clusters (e.g. ISET [6], FMSA [7], Cluster-chip [8]). Although these methods have been demonstrated to effectively isolate the CTC clusters from the background cells mainly based on their size difference, the influence of shear stress on physical size of CTC cluster, or the viability of the cells isolated is still a problem. To address this issue, The key advantages of ODEP mechanism for cell isolation including: (1) no need of complex microfabrication process for constructing microfilter structures, and (2) the reduction of shear stress acting on the cells manipulated. However, the feasibility of using ODEP-based mechanism for the isolation of CTC cluster (i.e. CTC cell aggregates) has not yet been explored. To test its feasibility, a T-shaped microfluidic chip was designed (Fig.1). A virtual microfilter consisting of multiple light patterns was designed at the CTC clusters isolation zone (Fig.1). By continuously moving and rotating the light patterns in the microfilter, the larger CTC clusters can be separated from the background leukocytes, and also transported to the side microchannel (Fig.2). In this work, the optimum ODEP operating conditions (e.g. moving velocity of light pattern) was explored. Results revealed that moving velocity of light pattern that can manipulate the CTC clusters (containing 2-13 cells) was significantly higher than the background of leukocytes (Fig.3). Based on this, the moving velocity of light pattern was set at 100 μm/sec (Fig.3). At a given sample flow rate of 0.5 μl/min, moreover, we found that the rotation speed of light patterns at 14 RPM could significantly increase the purity of CTC clusters isolation (Fig.4). Based on the set operating conditions, the recovery and purity of the isolated CTC clusters were experimentally evaluated to be 70.1 ± 7.1% and 60.8 ± 2.7%, respectively (Fig.4). As a whole, we have established a high purity CTC clusters isolation method that is easy to operate, and is possible to avoid the problem caused by the shear stress acting on the cells or particles.