Aysegul Abusoglu

Prof. Dr. Aysegul Abusoglu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

5 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
HOHuseyin Gunhan Ozcan
Huseyin Gunhan Ozcan
AHArif Hepbasli
Arif Hepbasli
AAAysegul Abusoglu
Aysegul Abusoglu
Amjad Anvari-MoghaddamAmjad Anvari-Moghaddam
Amjad Anvari-Moghaddam
The heating of the buildings, together with domestic hot water generation, is responsible for half of the total generated heating energy, which consumes half of the final energy demand. Meanwhile, district heating systems are a powerful option to meet this demand, with their significant potential and the experience accumulated over many years. The work described here deals with the conventional and advanced exergy performance assessments of the district heating system, using four different waste heat sources by the exhaust gas potentials of the selected plants (municipal solid waste cogeneration, thermal power, wastewater treatment, and cement production), with the real-time data group based on numerical investigations. The simulated results based on conventional exergy analysis revealed that the priority should be given to heat exchanger (HE)-I, with exergy efficiency values from 0.39 to 0.58, followed by HE-II and the pump with those from 0.48 to 0.78 and from 0.81 to 0.82, respectively. On the other hand, the simulated results based on advanced exergy analysis indicated that the exergy destruction was mostly avoidable for the pump (78.32–78.56%) and mostly unavoidable for the heat exchangers (66.61–97.13%). Meanwhile, the exergy destruction was determined to be mainly originated from the component itself (endogenous), for the pump (97.50–99.45%) and heat exchangers (69.80–91.97%). When the real-time implementation was considered, the functional exergy efficiency of the entire system was obtained to be linearly and inversely proportional to the pipeline length and the average ambient temperature, respectively.

15 February 2023 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
HOHuseyin Gunhan Ozcan
Huseyin Gunhan Ozcan
AHArif Hepbasli
Arif Hepbasli
AAAysegul Abusoglu
Aysegul Abusoglu
Amjad Anvari-MoghaddamAmjad Anvari-Moghaddam
Amjad Anvari-Moghaddam


29 March 2026 in The International Journal of Materials and Engineering Technology
Verified
Journal Article
Open access
AAAysegul Abusoglu
Aysegul Abusoglu
The Extended Exergy Accounting (EEA) method assesses the exergy value of labor as equivalent to the primary exergy required to produce and sustain the workforce essential to the system's long-term operation. The neoclassical economic approach, which incorporates capital flows into the thermodynamic framework, falls short in revealing the environmental impacts of various industrial, agricultural, and financial activities. In contrast, the exergy method provides a robust basis for examining the ecological effects of production activities. It allows us to directly calculate the cost of balancing wastes with environmental conditions. Evaluations of waste disposal processes and waste-to-energy (WtE) studies using the EEA method facilitate the determination of service costs in environmental impact management. In this study, a real gas turbine biopower plant, which generates 32.0 GWh of electricity and 33.5 GWh of heat annually and employs approximately 700 people, was analyzed using the EEA method. First, all sub-processes, from raw material input to electricity and heat production, were assessed using the classical exergy method. The system boundaries were then expanded to include emissions from raw material transportation, the labor and capital required for transportation, and waste management following the completion of the production process. These were evaluated through analysis using the EEA method. The exergy efficiency of the biopower plant was 52%, while the bio-methanization unit, responsible for biogas production, had an exergy efficiency of 39%. By applying the EEA method, the labor, capital, and environmental impact factors within the expanded control volume of the biopower plant were quantified in exergy units. Results showed that the exergy equivalent of the labor factor per working hour was 27.64 MJ/h, and that of the unit capital was 18.30 MJ/USD. The environmental impact assessment examined three interconnected systems responsible for disposing of emissions—CO2, N2O, CH4, and compost—generated within the expanded control volume. The labor and capital inputs for each of these systems were calculated separately.