BACKGROUND: Few studies have measured ventilation during early cardiopulmonary resuscitation (CPR) before advanced airway placement. Resuscitation guidelines recommend pauses after every 30 chest compressions to deliver ventilations. The effectiveness of bag-valve-mask ventilation delivered during the pause in chest compressions is unknown. We sought to determine: (1) the incidence of lung inflation with bag-valve-mask ventilation during 30:2 CPR; and (2) the association of ventilation with outcomes after out-of-hospital cardiac arrest. METHODS: We studied patients with out-of-hospital cardiac arrest from 6 sites of the Resuscitation Outcomes Consortium CCC study (Trial of Continuous Compressions versus Standard CPR in Patients with Out-of-Hospital Cardiac Arrest). We analyzed patients assigned to the 30:2 CPR arm with ≥2 minutes of thoracic bioimpedance signal recorded with a cardiac defibrillator/monitor. Detectable ventilation waveforms were defined as having a bioimpedance amplitude ≥0.5 Ω (corresponding to ≥250 mL V T ) and a duration ≥1 s. We defined a chest compression pause as a 3- to 15-s break in chest compressions. We compared the incidence of ventilation and outcomes in 2 groups: patients with ventilation waveforms in <50% of pauses (group 1) versus those with waveforms in ≥50% of pauses (group 2). RESULTS: Among 1976 patients, the mean age was 65 years; 66% were male. From the start of chest compressions until advanced airway placement, mean±SD duration of 30:2 CPR was 9.8±4.9 minutes. During this period, we identified 26 861 pauses in chest compressions; 60% of patients had ventilation waveforms in <50% of pauses (group 1, n=1177), and 40% had waveforms in ≥50% of pauses (group 2, n=799). Group 1 had a median of 12 pauses and 2 ventilations per patient versus group 2, which had 12 pauses and 12 ventilations per patient. Group 2 had higher rates of prehospital return of spontaneous circulation (40.7% versus 25.2%; P <0.0001), survival to hospital discharge (13.5% versus 4.1%; P <0.0001), and survival with favorable neurological outcome (10.6% versus 2.4%; P <0.0001). These associations persisted after adjustment for confounders. CONCLUSIONS: In this study, lung inflation occurred infrequently with bag-valve-mask ventilation during 30:2 CPR. Lung inflation in ≥50% of pauses was associated with improved return of spontaneous circulation, survival, and survival with favorable neurological outcome.
Automated External Defibrillators (AED) incorporate a shock decision algorithm that analyzes the patient’s electrocardiogram (EKG), allowing lay persons to provide life saving defibrillation therapy to out-of-hospital cardiac arrest (OHCA) patients. The most accurate shock decision algorithms are based on deep learning, but these algorithms have not been trained and tested using OHCA data. In this study we propose novel deep learning architectures for shock decision algorithms based on convolutional and residual networks. EKG electronic recordings from a cohort of 852 OHCA cases (4216 AED EKG analyses) were used in the study. EKGs were annotated by a pool of six expert clinicians resulting in 3718 nonshockable and 498 shockable EKGs. Data were partitioned patient wise in a stratified way to train and test the models using 10-fold cross validation, and the procedure was repeated 100 times for statistical evaluation. Performance was assessed using sensitivity (shockable), specificity (non-shockable) and accuracy, and the analysis was conducted for EKG segments of decreasing duration. The best model had median (interdecile range) accuracies of 98.6 (98.5 – 98.7)%, 98.4 (98.2 – 98.6)%, 98.2 (97.9 – 98.4)%, and 97.6 (97.4 – 97.8)%, for 4, 3, 2 and 1 second EKG segments, respectively. The minimum 90% sensitivity and 95% specificity requirements established by the American Heart Association for shock decision algorithms were met, and the best model presented significantly greater accuracy (p<0.05 McNemar test) than previous deep learning solutions for all segment durations. Moreover, the first AHA compliant shock decision algorithm using 1-s segments was demonstrated. This should contribute to a combined optimization of defibrillation and cardiopulmonary resuscitation therapy to improve OHCA survival.
17 January 2020 in IEEE Journal of Biomedical and Health Informatics
Feedback on chest compressions and ventilations during cardiopulmonary resuscitation (CPR) is important to improve survival from out-of-hospital cardiac arrest (OHCA). The thoracic impedance signal acquired by monitor-defibrillators during treatment can be used to provide feedback on ventilations, but chest compression components prevent accurate detection of ventilations. This study introduces the first method for accurate ventilation detection using the impedance while chest compressions are concurrently delivered by a mechanical CPR device. A total of 423 OHCA patients treated with mechanical CPR were included, 761 analysis intervals were selected which in total comprised 5 884 minutes and contained 34 864 ventilations. Ground truth ventilations were determined using the expired CO2 channel. The method uses adaptive signal processing to obtain the impedance ventilation waveform. Then, 14 features were calculated from the ventilation waveform and fed to a random forest (RF) classifier to discriminate false positive detections from actual ventilations. The RF feature importance was used to determine the best feature subset for the classifier. The method was trained and tested using stratified 10-fold cross validation (CV) partitions. The training/test process was repeated 20 times to statistically characterize the results. The best ventilation detector had a median (interdecile range, IDR) F1-score of 96.32 (96.26-96.37). When used to provide feedback in 1-min intervals, the median (IDR) error and relative error in ventilation rate were 0.002 (-0.334-0.572) min -1 and 0.05 (-3.71-9.08)%, respectively. An accurate ventilation detector during mechanical CPR was demonstrated. The algorithm could be introduced in current equipment for feedback on ventilation rate and quality, and it could contribute to improve OHCA survival rates.
7 March 2023 in IEEE Journal of Biomedical and Health Informatics
Feedback on ventilation could help improve cardiopulmonary resuscitation quality and survival from out-of-hospital cardiac arrest (OHCA). However, current technology that monitors ventilation during OHCA is very limited. Thoracic impedance (TI) is sensitive to air volume changes in the lungs, allowing ventilations to be identified, but is affected by artifacts due to chest compressions and electrode motion. This study introduces a novel algorithm to identify ventilations in TI during continuous chest compressions in OHCA. Data from 367 OHCA patients were included, and 2551 one-minute TI segments were extracted. Concurrent capnography data were used to annotate 20724 ground truth ventilations for training and evaluation. A three-step procedure was applied to each TI segment: First, bidirectional static and adaptive filters were applied to remove compression artifacts. Then, fluctuations potentially due to ventilations were located and characterized. Finally, a recurrent neural network was used to discriminate ventilations from other spurious fluctuations. A quality control stage was also developed to anticipate segments where ventilation detection could be compromised. The algorithm was trained and tested using 5-fold cross-validation, and outperformed previous solutions in the literature on the study dataset. The median (interquartile range, IQR) persegment and per-patient F 1 -scores were 89.1 (70.8–99.6) and 84.1 (69.0–93.9), respectively. The quality control stage identified most low performance segments. For the 50% of segments with highest quality scores, the median per-segment and per-patient F 1 -scores were 100.0 (90.9–100.0) and 94.3 (86.5–97.8). The proposed algorithm could allow reliable, quality-conditioned feedback on ventilation in the challenging scenario of continuous manual CPR in OHCA.